Included: the control box with its start and run capacitors, relay and overloads, and the magnetic line contactor.
Motor: a Baker 6 in single-phase three-wire motor of the same horsepower and voltage; the Models table gives the motor model each box matches.
Wiring and conduit: sized at install; the box has 1/2 in and 1 in conduit knockouts.
Baker control boxes run Baker single-phase three-wire pump and motor assemblies. The 6 in Deluxe box, with a magnetic line contactor, capacitor start and capacitor run, covers Baker 6 in single-phase motors from 7 1/2 to 15 HP.
Every box has a metal casing and auxiliary contacts for control by probes, with thermal protection and an external manual reset.
Covered for 2 years from the date of manufacture or 1 year from the date of installation, whichever comes first, under A.Y. McDonald’s standard limited warranty for Baker products.
| Model | Part No. | HP | Voltage | kW | Start Capacitor | Run Capacitor | Weight |
|---|---|---|---|---|---|---|---|
| SC0613 7.5HP230VD | 6619-001 | 7 1/2 | 230V | 5.0 | 270-324 µF, 330V | 45 µF, 370V | 13 lb |
| SC0613 10HP230VD | 6619-002 | 10 | 230V | 7.5 | 270-324 µF, 330V | 35 µF, 370V | 14 lb |
| SC0613 15HP230VD | 6619-003 | 15 | 230V | 11 | 270-324 µF, 330V | 45 µF, 370V | 16 lb |
Sources: Pumps by Baker catalog (Sept 2025, rev 3/26), p. 198; weights from the Baker Pumps and Accessories price list, effective 7/1/2026. The catalog prints more than one starting-capacitor rating for some models (SC0613 7.5HP230VD: 270-324 or 216-260 µF; SC0613 10HP230VD: 270-324 or 216-260 or 130-156 µF; SC0613 15HP230VD: 270-324 or 161-193 µF); the first is shown.
| Motor type | Baker 6 in single-phase three-wire submersible motors |
| Frequency | 60 Hz |
| Casing | Metal |
| Controls | Auxiliary contacts for control by probes; thermal protection with external manual reset |
| Dimensions (A x B x C) | 8.3 x 15.4 x 6.3 in (B1 16.5 in) |
| App connection | None |
Source: Pumps by Baker catalog (Sept 2025, rev 3/26), p. 198.
Match the box to the motor: same horsepower and voltage, and a Baker single-phase three-wire motor. Two-wire motors need no control box; three-phase motors take a starter kit instead.
| Box Model | Starting Capacitor | Running Capacitor | Starting Overload | Running Overload | Control Relay | Contactor |
|---|---|---|---|---|---|---|
| SC0613 7.5HP230VD | 3132-630 | 3132-633 | 3132-636 | 3132-639 | 3132-642 | 3132-645 |
| SC0613 10HP230VD | 3132-631 | 3132-634 | 3132-637 | 3132-640 | 3132-643 | 3132-646 |
| SC0613 15HP230VD | 3132-632 | 3132-635 | 3132-638 | 3132-641 | 3132-644 | 3132-647 |
Starting Capacitor · Running Capacitor · Starting Overload · Running Overload · Control Relay · Contactor
Replacement part numbers from the Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 198 and 343. These parts fit Baker control boxes only.