Franklin Electric Engine-Driven, Hydraulic, Solar and Bare-Shaft Pumps

Franklin Electric engine-driven, hydraulic, bare-shaft and solar surface pumps for sites where the pump runs off a gas engine, a hydraulic circuit, your own motor or engine, or a solar array. Gas engine pumps (FACGF, FNG-23V, FBSGF, FNSGF, FMIG) come complete with a 3.5 to 23 HP Briggs and Stratton, Honda or Kohler engine and deliver up to 400 GPM or 275 ft of head. XS 3x4-9 hydraulic-drive pumps take an SAE B or C spline hydraulic motor in CW or CCW rotation. The bare-shaft FAOT, FACT, FBSTF, FMIT and XS frame-mount pumps couple to your own driver and reach 2,800 GPM on the XS 13 in frame. The Fhoton Surface SolarPAK pairs a 1.1 kW Fhoton solar controller with a Franklin surface pump, motor and low-flow switch in 1/2 to 1-1/2 HP packages. All share cast iron volutes, carbon/ceramic or packed shaft seals and NPT, grooved or flanged connections, with working pressures from 120 psi to 350 psi depending on series. We supply U.S. 60 Hz builds and offer engineering-led sizing that matches the pump to your engine, hydraulic circuit, motor or solar array against the Franklin curve. Call 1-888.510.4036 or email sales@watermainsupply.com for a selection and quote.

4 products
Sort by:
Most relevant
Sort by:
Most relevant
Franklin Electric Hydraulic Motor Drive Centrifugal Pump - Motor Not Included

Franklin Electric

Free Shipping $499 or more

Franklin Electric Hydraulic Motor Drive Centrifugal Pump - Motor Not Included

Price
From $5,792.98
Franklin Electric Gas Engine-Driven Centrifugal Pump
Franklin Electric FACGF gas engine-driven centrifugal pump

Franklin Electric

Free Shipping $499 or more

Franklin Electric Gas Engine-Driven Centrifugal Pump

Price
From $1,664.56
Franklin Electric Fhoton Surface Solar Pump Package

Franklin Electric

Free Shipping $499 or more

Franklin Electric Fhoton Surface Solar Pump Package

Price
From $3,625.96
Franklin Electric Bare-Shaft Centrifugal Pump - Driver Not Included

Franklin Electric

Free Shipping $499 or more

Franklin Electric Bare-Shaft Centrifugal Pump - Driver Not Included

Price
From $615.79

Franklin Electric Engine-Driven, Hydraulic, Solar and Bare-Shaft Pumps

Franklin Electric

Franklin Electric Engine-Driven, Hydraulic, Solar and Bare-Shaft Pumps

Franklin Electric centrifugal and self-priming pumps for sites where the power comes from a gas engine, a hydraulic circuit, your own motor or engine, or a solar array. Gas engine pumps from 3.5 to 23 engine HP, XS frame-mount pumps to 2,800 GPM, and Fhoton Surface SolarPAK systems from 1/2 to 1-1/2 HP.

Franklin Electric FACGF gas engine-driven centrifugal pump
3.5–23 HPGas engine range
400 GPMEngine pump max flow
2,800 GPMXS 13 in frame max
SAE B / CHydraulic motor fit
1/2–1-1/2 HPFhoton SolarPAK

This collection covers the Franklin Electric surface pumps that are bought by their driver rather than by their motor: gas engine-driven centrifugal and self-priming pumps (FACGF, FNG-23V, FBSGF, FNSGF, FMIG), XS frame-mount pumps machined for a hydraulic motor, bare-shaft frame-mount pumps (FAOT, FACT, FBSTF, FMIT and XS) that you couple to your own motor or engine, and the Fhoton Surface SolarPAK for pumping off a solar array. It is written for water-truck and spray-rig builders, irrigation and dewatering contractors, OEMs, and owners of remote sites with no utility power.

We supply U.S. 60 Hz builds and help you match the pump to the driver you actually have: engine HP, hydraulic flow, pressure and rotation, shaft size and speed, or PV array voltage and wattage. Send us the duty point and the driver details and we will run an engineering-led selection against the Franklin curves — call 1-888.510.4036. Genuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.

Will It Work for Me?

Four checks that settle most specialty pump orders. The driver decides the fit here as much as the pump does.

Warranty

Franklin warrants these pumps against defects in material and workmanship for 12 months from the date of installation or 24 months from the date of manufacture, whichever occurs first, per the FACGF, FAOT and FBSTF Series Owner’s Manuals. XS frame-mount and Fhoton packages carry the terms printed in the manual shipped with the unit.

Full terms and conditions are in the manufacturer’s manual.

Reliability

Cast iron volutes, carbon/ceramic mechanical seals with 300-series stainless hardware, and heavy iron bearing frames with oversized shafts on the XS. The FMIG adds a replaceable steel wear plate and handles mud, sand or silt up to 10% by volume.

Fit

Engine and surface pumps lift water up to 25 ft vertical from pump to water level, less at altitude. Beyond that, the driver rules the job: engine pumps turn clockwise viewed from the engine side, hydraulic XS pumps need the matching SAE B or C spline and CW or CCW rotation, and the Fhoton 1.1 kW controller needs a PV array under 420 V open circuit.

Match It Now

Send the flow, head or pressure, suction lift, and your driver details (engine HP, hydraulic motor spec, motor frame and RPM, or array layout). We return a selection checked against the manufacturer curve.

Request a quote and selection
1-888.510.4036 · sales@watermainsupply.com

Franklin Electric Specialty Surface Pump Lines

Three groups by driver: a gas engine on the pump, a driver you supply (hydraulic motor, electric motor or engine), or the sun.

Franklin Electric FBSGF self-priming gas engine-driven pump

Gas Engine-Driven Pumps

FACGF · FNG-23V · FBSGF · FNSGF · FMIG

3.5–23 HPEngine HP
400 GPMMax flow
275 ftMax head (FACGF)
2–4 inNPT ports

Complete pump-and-engine units with Briggs & Stratton, Honda or Kohler engines and adjustable throttle. FACGF and FNG-23V are standard centrifugals with enclosed impellers for pressure; FBSGF, FNSGF and FMIG are self-priming for transfer and temporary irrigation.

Key specs

  • 14 models across five series, 3.5 to 23 engine HP
  • 150 psi max (FACGF), 125 psi (FNG-23V), 120 psi (FBSGF, FNSGF, FMIG)
  • 200 °F max; 212 °F on FNG-23V and FMIG
  • Electric start on FACGF-23K, FNG-23VM, FMIG40-18K (battery, cables, tank not included)

Best forWater trucks, irrigation, construction dewatering, mining and municipal transfer away from power

View Gas Engine Pumps

Hydraulic & Bare-Shaft Pumps

XS frame mount · FAOT · FACT · FBSTF · FMIT · FMIH

2,800 GPMXS 13 in max
360 ftXS 13 in max head
350 psiXS 13 in max
CW / CCWXS 3x4-9 rotation

Pump end and bearing frame, driver not included. The XS 3x4-9 comes bare-shaft or with a hydraulic motor mount (B or C fit) in either rotation; the XS 13 in frames and the FAOT, FACT, FBSTF and FMIT models couple to your motor or engine by belt or direct drive.

Key specs

  • XS 9 in: 1,000 GPM, 260 ft, 250 psi, 212 °F
  • Packing or mechanical seal; NPT, grooved or Class 150 flanged
  • Shafts 0.75 in (FAOT, FACT, FBSTF) to 1.63 in (FMIT-40)
  • Vertical or horizontal mounting

For a truck or machine with a hydraulic circuit, see the Franklin Electric hydraulic motor drive centrifugal pump.

Best forWater trucks, spray rigs, OEM skids, belt-driven irrigation, booster and jockey duty

View Bare-Shaft Pumps

Fhoton Surface SolarPAK

FDSP · controller + pump + flow switch

1/2–1-1/2 HPSystem HP
1.1 kWFhoton controller
115–420 VDC input
Type 4Enclosure

A matched solar pumping system: the Fhoton solar controller, a Franklin surface pump and 208-230 V three-phase motor, and a low-flow cut-off switch. Four packages cover booster, end suction and self-priming duty.

Key specs

  • FDSP-0.5HP-7BT4, FDSP-1HP-FCE, FDSP-1.5HP-30MH, FDSP-1.5HP-TB
  • Up to 2,000 W PV input, 98% efficiency at max power
  • MPPT and soft start
  • NPT connections; array quoted separately

Best forTurf irrigation, livestock watering, cistern boosting, fountains, rainwater harvesting

View Fhoton SolarPAK

All products in this collection

Product Driver Models Order numbers
Gas Engine-Driven Centrifugal Pump Gas engine, included FACGF-5, -5H, -8H, -23K; FNG-23VM; FBSGF-8, -8H, -10, -10H, -12H; FNSGF-5H, -8H; FMIG30-13H; FMIG40-18K 90261005, 90261105, 90261108, 90261323, 90261223 and 9 more (14)
Hydraulic Motor Drive Centrifugal Pump Hydraulic motor, not included FMIH-40; XS439-HB (B fit) and XS439-HC (C fit), packing or mechanical seal, NPT or grooved, CW or CCW 90295004; 68040309100 to 69040309401 (17)
Bare-Shaft Centrifugal Pump Motor or engine, not included FMIT-20, -30, -40; FAOT-4, -5, -6; FACT-8; FBSTF-1, -2, -3, -5; XS439-BF; XS4313; XS6413H; XS8613 90230002 to 90253004; 64040309100 to 65080613102 (25)
Fhoton Surface Solar Pump Package PV array via Fhoton controller FDSP-0.5HP-7BT4; FDSP-1HP-FCE; FDSP-1.5HP-30MH; FDSP-1.5HP-TB 91040725; 91240025; 91143025; 91340025

Engine vs Hydraulic vs Bare-Shaft vs Solar

How the four product groups compare on the figures that decide a specialty pump order.

Spec Gas engine-driven Hydraulic drive (XS439-H) Bare-shaft (FAOT, FACT, FBSTF, FMIT, XS) Fhoton Surface SolarPAK
Driver Included — Briggs & Stratton, Honda, Kohler Your hydraulic motor, SAE B or C spline Your motor or engine, belt or direct Included — 208-230 V 3-ph motor + Fhoton
Power range 3.5 to 23 engine HP Set by your circuit and the curve 1 to 5 motor HP (FAOT, FACT, FBSTF at 3450–3600 RPM); XS per curve 1/2 to 1-1/2 HP; up to 2,000 W PV
Max flow 400 GPM (FACGF, FMIG) 1,000 GPM 2,800 GPM (XS 13 in) Nominal 7 GPM (7BT4) to 30 GPM (30MH)
Max head 275 ft (FACGF) 260 ft 360 ft (XS 13 in) Per Franklin curve for each package
Max working pressure 120 to 150 psi 250 psi 120 psi (FPS) to 350 psi (XS 13 in) Per pump model
Max water temp 200 or 212 °F 212 °F 200 °F (FBSTF) or 212 °F Controller ambient -13 to 122 °F
Rotation CW, viewed from engine side CW or CCW CW; CCW on XS439-BF Set by controller
Speed Engine throttle Set by hydraulic flow 1750–3450 RPM (FAOT); XS curves 1,400–3,000 RPM 20–60 Hz output, follows the sun
Self-priming option FBSGF, FNSGF, FMIG FBSTF FDSP-1.5HP-TB
Connections 2 to 4 in NPT 4 x 3 in NPT or grooved NPT, grooved, Class 150 flanged NPT
Seal Carbon/ceramic, FKM Packing or mechanical Mechanical; packing option on XS Per pump model
Mounting Horizontal, on base On the hydraulic motor mount Vertical or horizontal Surface, near the source
Solids FMIG to 10% mud, sand, silt Clear water FAOT open impeller; FBSTF non-clogging Clear water
Utility power needed No No Depends on your driver No
Order numbers 14 17 (incl. FMIH-40) 25 4

Sources: Engine Driven FPS Series Catalog (Mi4064), Frame Mount XS Series Catalog (Mi4063), Frame Mount FPS Series Catalog (M5423), Solar Products Catalog (M1782), Fhoton Installation Guide (226772101).

Quick rule. If the site has no power and the job moves, buy the engine pump. If the vehicle already has a hydraulic circuit, buy the XS hydraulic mount in the right spline and rotation. If you already own the motor or engine, or need more than 400 GPM, buy bare-shaft. If the water point is remote and the demand is small and daytime, buy the Fhoton SolarPAK.

Selection Guide by Application

Typical starting points. We confirm every selection against the manufacturer curve and submittal before you order.

Application Typical need Recommended family Notes
Water truck fill and spray High flow, truck hydraulics XS439-HB or XS439-HC Match spline, rotation and grooved or NPT ports to the truck
Construction dewatering Portable, dirty water, reprime FMIG30-13H, FMIG40-18K Built-in check valve; solids to 10% by volume
Temporary irrigation Portable transfer, moderate head FBSGF, FNSGF FBSGF to 298 GPM; FNSGF to 185 ft
Irrigation or pressure at distance Higher head, engine power FACGF, FNG-23VM To 275 ft; FACGF-23K and FNG-23VM at 23 HP
Belt-driven booster or jockey Low flow, your motor FAOT-4 to FAOT-6, FACT-8 FAOT 1750–3450 RPM; FACT to 150 ft
Self-priming transfer, own driver Suction lift, your motor or engine FBSTF-1 to FBSTF-5 1 to 5 motor HP at 3450 RPM
Large irrigation or municipal skid 500 to 2,800 GPM XS4313, XS6413H, XS8613 Class 150 flanged; CW only
Livestock water, cistern boost Low flow, no utility power FDSP-0.5HP-7BT4, FDSP-1.5HP-30MH Booster pumps; array quoted separately
Solar turf irrigation Flow for sprinklers, suction lift FDSP-1.5HP-TB Turf Boss self-priming pump
Fountain or water feature Circulation off-grid FDSP-1HP-FCE End suction; runs with daylight

Driver Sizing & Best Practices

The pump is sized from the duty point; the driver is then sized from the pump curve at that duty point. Most mistakes on these orders come from sizing the driver off the pump size instead of the curve.

Step 1: Total dynamic head

TDH = static lift + friction losses + required pressure × 2.31 ft/psi. Going the other way, 1 ft of water column equals 0.433 psi. Check suction first: these pumps are rated for a vertical distance of up to 25 ft from pump to water level, including drawdown, and less at altitude. Keep suction lines short, one size larger than the pump inlet on long runs, and sloping up to the pump. Confirm available NPSH exceeds the NPSH required on the curve, especially on the XS at high flow.

Worked example (engine pump). Transfer from a pond with 10 ft of suction lift, up 40 ft of elevation, through piping with 25 ft of friction loss, delivering 30 psi at the outlet. Pressure head = 30 × 2.31 = 69.3 ft. TDH = 10 + 40 + 25 + 69.3 = 144.3 ft. The 40 ft rise alone is 40 × 0.433 = 17.3 psi of backpressure. Step-up rule: keep the duty point at or below about 70% of the pump’s maximum head, so look for a maximum head of at least 144.3 ÷ 0.70 = 206 ft. That points to the FACGF family (to 275 ft) rather than the FNSGF (to 185 ft). We then confirm the flow at 144.3 ft on the FACGF curve for the engine size you choose.

Step 2: Match the driver

Engine HP

On engine-driven models the engine is matched by Franklin; pick the model whose curve covers your duty point. Larger engines move more water: in the FBSGF table, the 9 HP FBSGF-12H moves 310 GPM at 30 ft against 135 GPM for the 3.5 HP FBSGF-8. Rotation is clockwise viewed from the engine side. Run at the throttle setting that holds the duty point; if the pump will not catch prime, low engine speed is one of the first checks in the FACGF manual.

Hydraulic flow, pressure, rotation

Motor speed (RPM) = hydraulic flow (GPM) × 231 ÷ motor displacement (cu in/rev). Hydraulic HP = GPM × psi ÷ 1714. Torque (lb-in) = psi × displacement ÷ 6.28. Example: to turn the pump at 2,200 RPM with a 2.5 cu in/rev motor needs 2,200 × 2.5 ÷ 231 = 23.8 GPM. If the curve shows 20 HP at your duty point and the motor is 85% efficient, you need 23.5 hydraulic HP, or 23.5 × 1714 ÷ 23.8 = about 1,690 psi. Then match the spline (B fit: SAE B, 13 tooth, 16/32 pitch; C fit: SAE C, 14 tooth, 12/24 pitch) and the rotation, CW or CCW.

Bare-shaft coupling

Match rotation (CW viewed from the drive end on FAOT, FACT, FBSTF), shaft diameter and keyway, and speed. The FAOT is published for 1750 to 3450 RPM; operation outside that range is not recommended. Size motor HP from the curve at the actual speed: FAOT-6 needs 3 motor HP at 3450 RPM. On direct drive, lay a straightedge across both coupling halves at 3 or 4 positions; on belt drive, keep the pulleys in line. Coupling, guard and baseplate are not included.

Solar array and power

The Fhoton 1.1 kW controller accepts 115 to 420 V DC and up to 2,000 W, with 420 V open circuit as the absolute maximum and no more than 50 A DC short-circuit current. Size the string so cold-morning open-circuit voltage stays under 420 V, and treat 115 V as a floor, not a design point. Output is 200 V AC three-phase at 20 to 60 Hz to a 208-230 V motor. Flow follows sunlight, so size storage for night and cloudy-day demand.

What to send us

Flow (GPM), TDH or discharge pressure, suction lift and water temperature; the driver: engine preference and HP, hydraulic motor make, displacement, spline, rotation and circuit flow and pressure, or motor HP, frame, RPM and voltage; connection type (NPT, grooved or flanged); and for solar, your location, daily water demand and panel details if you already have them. See our guide to reading a pump curve for how we check the duty point.

Performance & Ratings

Published Franklin Electric figures only. Where Franklin publishes a curve rather than a table, we quote the limits and select from the curve for you.

Series limits

Series Type Max flow Max head Max pressure Max temp
FACGF / FNG-23V Engine, centrifugal 400 GPM 275 ft 150 psi / 125 psi 200 °F / 212 °F
FBSGF Engine, self-priming 298 GPM 112 ft 120 psi 200 °F
FNSGF Engine, self-priming 165 GPM 185 ft 120 psi 200 °F
FMIG Engine, self-priming 400 GPM 160 ft 120 psi 212 °F
XS 3x4-9 Bare-shaft or hydraulic 1,000 GPM 260 ft 250 psi 212 °F
XS 13 in Bare-shaft 2,800 GPM 360 ft 350 psi 212 °F
FAOT Bare-shaft, end suction 120 GPM 85 ft 120 psi 212 °F
FACT Bare-shaft, end suction 175 GPM 150 ft 120 psi 212 °F
FBSTF Bare-shaft, self-priming 250 GPM 80 ft 120 psi 200 °F

FBSGF capacity (US GPM) at total head

Model 30 ft 40 ft 50 ft 60 ft 70 ft 80 ft 90 ft 100 ft
FBSGF-8 135 120 105 85 65 37
FBSGF-10 170 165 155 140 118 95 65 30
FBSGF-12H 310 285 255 220 175 120 60

FNSGF capacity (US GPM) at discharge pressure, 5 ft lift

Model 10 psi 20 psi 30 psi 40 psi 50 psi 60 psi 70 psi 80 psi
FNSGF-5H 132 115 106 85 70 52
FNSGF-8H 165 162 145 125 110 85 50 30

Bare-shaft driver power (motor HP, nameplate)

Model Order no. Suction x discharge Shaft Motor HP Speed
FAOT-4 90251004 1.25 x 1 in NPT 0.75 in 1 3450 RPM
FAOT-5 90251005 1.5 x 1.25 in NPT 0.75 in 2 3450 RPM
FAOT-6 90251006 2 x 1.5 in NPT 0.75 in 3 3450 RPM
FACT-8 90252008 2 x 2 in NPT 0.75 in 5 3600 RPM nominal
FBSTF-1 / -2 / -3 / -5 90253001 to 90253004 See product listing 0.75 in 1 / 2 / 3 / 5 3450 RPM

Fhoton 1.1 kW solar controller

Rating Value Rating Value
PV input voltage 115–420 V DC Output 200 V AC, 3-phase, 6.8 A per phase
Max input 6.2 A DC continuous; up to 2,000 W Output frequency 20–60 Hz
Absolute max 420 V open circuit; 50 A short circuit Efficiency at max power 98%
Enclosure Type 4 Ambient -13 to 122 °F

Sources: Engine Driven FPS Series Catalog (Mi4064); Frame Mount XS Series Catalog (Mi4063); Frame Mount FPS Series Catalog (M5423); FAOT and FBSTF Series Owner’s Manuals; Fhoton Installation Guide (226772101), Table 7. A dash means the pump does not deliver at that point. Request the manufacturer curve for your exact model.

Features That Matter on the Install

What the construction does for you once the pump is on the truck, the skid or the pad.

Back pull-out XS volute

The heavy-duty cast iron XS volute uses a back pull-out design and can be rotated during installation to line up with the piping on a truck or skid.

SAE B and C hydraulic fits

XS439-HB and XS439-HC pumps take the hydraulic motor directly on a cast iron motor mount and drive through a matching B or C fit shaft coupling, so the motor bolts to the pump frame.

CW or CCW rotation

The XS 3x4-9 is built in either rotation in bare-shaft and hydraulic versions, so the pump matches the PTO or motor direction you already have.

Heavy bearing frame

Oversized shaft, max-life bearings, external grease lubrication and a replaceable shaft sleeve on the XS carry belt loads and long duty cycles.

FMIG check valve and wear plate

A removable front cover with a built-in check valve helps priming, and the replaceable steel wear plate restores efficiency after dirty-water work.

Engine choice and low-oil shut-off

Briggs & Stratton, Honda or Kohler engines; most Honda and Kohler models have low-oil shut-off, which protects an engine left running unattended.

Fhoton MPPT and soft start

Maximum power point tracking pulls the most water from the array, and soft start reduces water hammer on long runs.

Low-flow cut-off included

Every SolarPAK ships with a C25 or F21 flow switch, which stops the pump before it runs dry when the source drops.

Related Parts & Products

Pump ends, seals and controls from the other Franklin Electric collections that pair with these pumps.

Gas Engine Pump End Kit

FACGF, FNG-23V, FBSGF, FNSGF and FMIG pump ends to rebuild an engine pump without buying a new engine.

Industrial Centrifugal Mechanical Seal

1.625 in seals for the XS 439 and 2.125 in seals for the XS 13 in, carbon/ceramic or SiC.

XS Series Pump End Kit

XS pump ends for close-coupled JP motor frames, when an electric close-coupled build suits better.

Franklin Electric X-Drive CEN VFD pump panel for centrifugal pumps

X-Drive CEN VFD Panel

Variable speed for a bare-shaft pump on an electric motor.

Repair Parts and Accessories

Seals, kits and service parts across the Franklin range.

Pump Ends and Stacks

Replacement pump ends for engine, XS, HC and VR pumps.

Match repair parts by the model and order number on the pump nameplate. We supply genuine Franklin Electric parts so the rebuilt pump performs to the published curve.

Why Buy From Watermain Supply

Engineering-Led Sizing

We size the pump from your duty point and the driver from the curve, then confirm against the manufacturer curve and submittal.

Multi-Brand Perspective

If Franklin Electric is not the right fit, we will say so and quote the one that is.

Account Terms Available

Net-30 for qualified contractor, property-management and municipal accounts.

Parts & Aftermarket

Pump end kits, seals and repair parts matched by model and order number for the life of the pump.

Driver Matched Correctly

Correct U.S. 60 Hz build, spline, rotation, shaft and voltage checked before the order is placed.

One Order, Houston-Based

Pump, motor, controls and parts on one order — based in Houston, serving the Gulf Coast.

Frequently Asked Questions

Engine-driven, hydraulic, bare-shaft and solar pump questions we hear most.

What warranty comes with these Franklin Electric pumps?

Franklin warrants the pump against defects in material and workmanship for 12 months from installation or 24 months from manufacture, whichever occurs first, per the FACGF, FAOT and FBSTF Series Owner’s Manuals. Full terms and conditions are in the manufacturer’s manual.

Which hydraulic mount do I need, B or C?

Match the spline on your hydraulic motor. The B fit is an SAE B spline, 13 tooth, 16/32 pitch; the C fit is an SAE C spline, 14 tooth, 12/24 pitch. Then choose CW or CCW rotation and NPT or grooved ports. Send us the motor data sheet and we will confirm the model code.

How much hydraulic flow and pressure does the XS pump need?

It depends on your duty point and motor. Speed equals GPM times 231 divided by motor displacement in cubic inches per revolution, and hydraulic HP equals GPM times psi divided by 1714. We read the pump HP from the Franklin curve at your speed and duty point and give you the circuit flow and pressure to plan for.

What motor size do I need for a bare-shaft pump?

Size it from the curve at the speed you will run. At 3450 RPM the FAOT-4, FAOT-5 and FAOT-6 need 1, 2 and 3 motor HP, the FBSTF-1 to FBSTF-5 need 1 to 5 motor HP, and the FACT-8 needs 5 motor HP at 3600 RPM nominal. XS frames are selected from multi-speed curves.

Which gas engine pump handles dirty water?

The FMIG self-priming pump has a semi-open non-clogging impeller that handles small amounts of mud, sand or silt, up to 10% by volume, with a replaceable steel wear plate and a built-in check valve for priming.

How high can these pumps lift water on the suction side?

The manuals rate these pumps for a vertical distance of up to 25 ft from pump to water level, including drawdown, and less at high altitude. Friction in the suction line reduces that further, so keep the pump close to the water.

What is included in a Fhoton Surface SolarPAK?

The Fhoton solar controller, the Franklin Electric pump and motor, and a low-flow cut-off switch. Solar panels, array mounting and wiring are quoted separately once we know your flow, pressure and location.

How big a solar array does the SolarPAK need?

The 1.1 kW Fhoton controller accepts 115 to 420 V DC and up to 2,000 W, with 420 V open circuit as the absolute limit. We size the array with Franklin from your daily water demand, pressure and location, keeping cold-weather open-circuit voltage under the limit.

Are the engine battery and fuel tank included on electric-start models?

The FACGF-23K, FNG-23VM and FMIG40-18K ship without battery, cables and fuel tank. Recoil-start models include the engine fuel tank listed for each model.

What is the lead time?

Lead time depends on the model and configuration. Send us the model or order number and we will confirm availability and lead time with your quote.

Ready to Match Your Pump to Its Driver?

Send the duty point and your engine, hydraulic motor, electric motor or solar details, and we will return a Franklin Electric selection checked against the manufacturer curve.

Technical data on this page is taken from Franklin Electric U.S. 60 Hz product literature and is subject to change by the manufacturer. Confirm against the current installation manual and pump curve before specifying.