Stainless steel vertical multistage pumps from 1/2 to 50 HP, packaged Tigercub simplex booster systems with a variable frequency drive, and self-priming Ocelot variable speed boosters for homes and light commercial buildings. Every selection is checked against TIGERFLOW’s published curve before it ships.

TIGERFLOW Systems builds packaged booster systems and the CD vertical multistage pump family that runs inside them. The CD is an in-line pump with laser-welded stainless steel impellers and chambers, a cartridge mechanical seal and a premium-efficiency TEFC motor, in ten flow classes from 4.4 to 374 GPM nominal. Around it TIGERFLOW offers the Tigercub simplex booster, the Ocelot 25, Ocelot 60 and Ocelot Duplex variable speed boosters, the T1HS stainless end suction pump and the TMHS threaded multistage pump.
Watermain Supply lists the full TIGERFLOW range: complete CD pumps and wet ends, Tigercub systems, Ocelot boosters, T1HS and TMHS pumps, TEFC replacement motors, seals, flange kits and tanks. Send your flow, pressure and power and we will reply the same day with a sized selection. Call 1-888.510.4036. Genuine TIGERFLOW equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
The four questions buyers ask first, answered from TIGERFLOW’s published data.
CD pumps and wet ends carry TIGERFLOW’s one-year guarantee under normal operating conditions, per the CD Series manual; wearable parts are excluded. Tigercub, Ocelot, T1HS, TMHS, motors and parts are covered for 12 months from the date of purchase.
Hydraulically balanced stainless impellers and guide vanes, stamped and laser-welded on robotic equipment. A cartridge seal in carbon, silicon carbide and Viton comes out as one piece, and the TEFC motors reach a Minimum Efficiency Index of up to 0.7.
CD: 362 psi maximum working pressure, liquid 5°F to 248°F as a guide, ANSI Class 300 flanges 1-1/4 to 4 in, fill and vent before start. T1HS: 115 psi, 14°F to 185°F. Ocelot: self-priming to 9 ft, water to 167°F.
Enter flow and pressure and the calculator returns the pumps that hold your duty point.
Or send the numbers: sales@watermainsupply.com · 1-888.510.4036
TIGERFLOW’s walkthrough of the cartridge seal swap on a CD pump, the most common service job on a vertical multistage pump.
CD cartridge mechanical seal replacement
Three families cover most jobs: the CD pump on its own, the CD packaged as a Tigercub booster, and the Ocelot for homes and light commercial buildings.

Ten flow classes, 1/2 to 50 HP
In-line suction and discharge on a common base, stacked stainless impellers and a NEMA TC-frame TEFC motor on top. More stages give more head at the same flow. Sold complete with motor or as a wet end.

A CD pump, drive and panel on one base
A CD3, CD5, CD10, CD15 or CD20 pump on a stainless base and manifold with a variable frequency drive and a UL 508A listed disconnect panel, prefabricated and factory tested. The drive holds constant pressure as demand changes.

Self-priming, permanent magnet motor
Variable speed boosters with an integrated drive, built-in expansion tank and check valves on suction and discharge, in a 304 stainless pump body. Low-flow detection slows or stops the pump when demand drops.
Also in the range: the TMHS multistage pump, six series from 1/2 to 10 HP with NPT threaded ports and an IP55 TEFC motor.
The model number is the nominal flow in cubic metres per hour. Pick the series whose flow range covers your duty, then the stage count that gives the head.
| Series | Nominal GPM | Max GPM | Max head (ft) | HP | Power | Flanges, Class 300 | Pump end |
|---|---|---|---|---|---|---|---|
| CD1 | 4.4 | On request | On request | 1/2 to 2 | 1Ph or 3Ph | 1-1/4 in | Wet end |
| CD3 | 13 | 22 | 643 | 3/4 to 5 | 1Ph or 3Ph | 1-1/4 in | Wet end |
| CD5 | 22 | 44 | 705 | 1 to 7-1/2 | 1Ph or 3Ph | 1-1/4 in | Wet end |
| CD10 | 44 | 74 | 807 | 2 to 15 | 3Ph | 2 in | Wet end |
| CD15 | 66 | 127 | 784 | 5 to 25 | 3Ph | 2 in | Wet end |
| CD20 | 88 | 154 | 666 | 5 to 25 | 3Ph | 2 in | Wet end |
| CD32 | 141 | 211 | 462 | 7-1/2 to 20 | 3Ph | 2-1/2 in | Wet end |
| CD42 | 185 | 286 | 453 | 7-1/2 to 40 | 3Ph | 3 in | Wet end |
| CD65 | 286 | 440 | 446 | 15 to 40 | 3Ph | 4 in | Wet end |
| CD85 | 374 | 572 | 540 | 15 to 50 | 3Ph | 4 in | Wet end |
Max GPM is where TIGERFLOW’s curve ends; max head is the shut-off head of the tallest model in the series. Power: 1Ph builds are 115/230V to 2 HP and 230V at 3 HP; 3Ph builds are 230/460V. CD1 curves are supplied by TIGERFLOW on request. Every series page carries the full model table in psi at four flows.
We sell every line below, so we can be straight about fit. Specifications are taken from our own product pages for each brand.
| Specification | TIGERFLOW CD10 | Grundfos CR 10 | Franklin Electric 10VR |
|---|---|---|---|
| Nominal flow | 44 GPM | 53.3 GPM rated | 60 GPM at BEP |
| Max head, tallest model | 807 ft | 817 ft | 2 to 17 stages |
| Motor range | 2 to 15 HP TEFC | 3/4 to 15 HP TEFC | 1-1/2 to 15 HP, ODP or TEFC |
| Single phase | No, 3Ph only on CD10 | Yes, to 3 HP | Yes, to 7-1/2 HP |
| Wetted materials | 304/316 stainless impellers and chambers; cast iron or 316 head and base | Cast iron head and base; other wetted parts 304 stainless | 316 stainless throughout (N version) |
| Connections | 2 in ANSI Class 300 flanges | 2 in NPT oval (232 psi) or 2 in ANSI 250 lb (362 psi) | 2 in round flange |
| Max working pressure | 362 psi | 232 psi oval; 362 psi ANSI | Per flange and piping rating |
| Liquid temperature | 5°F to 248°F guide | −4°F to 248°F (HQQE seal) | 14°F to 248°F |
| Seal | Cartridge: carbon / SiC / Viton | Cartridge HQQE or HQQV | Type 1 cartridge: graphite / SiC / EPDM |
| Drinking water | NSF/ANSI 61 and 372; cULus | NSF/ANSI 61 | NSF/ANSI 61 and 372 |
Verdict. The CD10 matches the CR 10 on maximum head and on the 362 psi rating, and comes with Class 300 flanges as standard and NSF/ANSI 372 plus cULus on the pump. Grundfos CR 10 is the pick when you need NPT oval flanges or a single-phase motor to 3 HP. Franklin 10VR wins where the water calls for 316 stainless throughout or the job needs a single-phase motor to 7-1/2 HP or an ODP motor.
| Specification | TIGERFLOW Ocelot 25 | TIGERFLOW Ocelot 60 | DAB Esybox Mini3 | DAB Esybox |
|---|---|---|---|---|
| Max flow | 24 GPM | 77 GPM | 22 GPM | 31.7 GPM |
| Max head | 164 ft (70 psi) | 230 ft (99 psi) | 183 ft (79 psi) | 213 ft (92 psi) |
| Motor | 1 HP | 2 HP | 1.1 HP (P1) | 2.1 HP (P1) |
| Power | 120V 1Ph | 208-230V 1Ph or 3Ph | 115-127V or 208-240V 1Ph | 230V 1Ph |
| Connections | 1 in NPT | 2 in NPT | 1 in NPT | 1 in NPT |
| Self-priming | 9 ft standard, to 25 ft | 9 ft standard, to 25 ft | 26 ft | 26 ft |
| Pump body | 304 stainless | 304 stainless | Glass-filled polypropylene | Technopolymer |
| Water temperature | 32°F to 167°F | 32°F to 167°F | 32°F to 104°F | To 104°F |
| Multi-pump | Single unit | Ocelot Duplex skid, lead-lag | Pairs with one more, wireless | Up to four, wireless |
| App | None | None | H2D app | H2D app |
| Weight | 17.6 lb | 53 lb | 32.2 lb | 59.5 lb |
| Warranty | 12 months from purchase | 12 months from purchase | 24 months from purchase | 24 months from purchase |
Verdict. The Ocelot 60 carries more than twice the flow of the Esybox, 77 against 31.7 GPM, runs on three-phase power as well as single phase, and takes water to 167°F in a stainless body. The Esybox and Mini3 lead on warranty (24 months), suction lift (26 ft), app control and wireless grouping. The Ocelot 25 is the choice when only 120V is available and the job needs a stainless pump body.
Typical selections by job. Demand figures are starting points; send us the duty for an engineering-led selection.
| Application | Typical duty | Recommended | Notes |
|---|---|---|---|
| Single home on low city pressure, 120V only | Up to 13 GPM at 39 psi boost | Ocelot 25 | Self-priming; works from a tank or cistern too. |
| Large home or light commercial, 208-230V | Up to 35 GPM at 61 psi boost | Ocelot 60 | Single or three phase; 2 in NPT. |
| Multifamily that needs a standby pump | Up to 70 GPM at 61 psi boost | Ocelot Duplex | Two Ocelot 60 pumps, lead-lag with alternation. |
| Commercial building that needs high boost | 22 to 154 GPM, boost to 305 psi | Tigercub CD3 to CD20 | Simplex; add the expansion tank and purge valve. |
| Boiler feed, RO, wash-down, industrial boosting | 4.4 to 374 GPM nominal | CD complete pump | Class 300 flanges; NPT companion flange kits available. |
| Worn pump end on a good motor | Same model as installed | CD wet end | Match motor frame and HP. |
| Transfer, circulation or irrigation at low head | 10 to 92 GPM, up to 56 psi | T1HS end suction | 304 stainless, 115 psi max working pressure. |
| Small threaded multistage replacement | 1/2 to 10 HP | TMHS | NPT threaded ports; send the old nameplate. |
Two numbers pick the pump: the flow you need and the pressure the pump must add at that flow.
Pressure needed at the outlet + 0.433 psi per foot of lift to the highest point + friction losses − pressure already at the pump inlet. Convert to feet of head by multiplying psi by 2.31.
Use the peak simultaneous demand, not the total connected load. Then pick the series whose nominal flow sits at or a little above your duty.

Inlet pressure plus shut-off pressure below 362 psi. Never run against a closed valve or below the minimum flow. Fill and vent before start; a suction lift works only where NPSH available exceeds NPSH required. Confirm the power: CD10 and larger are three phase.
The construction details that matter on an installation.
Impellers and guide vanes are stamped and laser-welded on robotic equipment and hydraulically balanced, for consistent clearances and lower axial thrust.
The carbon, silicon carbide and Viton seal comes out as one cartridge, so a seal change is a short job without disturbing the hydraulics.
Standard on every complete CD pump, with a Minimum Efficiency Index up to 0.7 on the pump end.
ANSI Class 300 flanged suction and discharge, in line, 1-1/4 to 4 in. NPT companion flange kits in 304 stainless or A105 carbon steel are listed separately.
The Tigercub is prefabricated and factory tested as one UL / cUL listed packaged pumping system with a UL 508A listed disconnect panel.
The Ocelot pairs a permanent magnet motor with an integrated drive; the pump slows as demand falls and stops at no flow.
The T1HS has a 304 stainless pump body, diffuser and impeller, closed-coupled to an IP55 / NEMA 4 TEFC motor.
CD and T1HS pumps are certified to NSF/ANSI 61 and NSF/ANSI 372 and are cULus Listed.
Order them with the pump so the job ships together.
The pump end without motor, for every CD model from CD1 to CD85.
3/4 to 30 HP, 56C to 286TSC, 230/460V 3Ph or 115/230V 1Ph.
Diaphragm tanks rated 150 psi for the Tigercub and the Ocelot Duplex.
Bleeds hot water off a Tigercub at low flow to protect the pump.
Also listed: CD cartridge mechanical seals, NPT companion flange kits, CD connection options and Ocelot Duplex accessories.
Send the duty and we select the series, stage count and motor from TIGERFLOW’s published curves, with the margin shown.
Flow, pressure and power in the morning; a sized selection, accessories and ship date back the same day.
Every order is checked against the curve for your flow, inlet pressure and set point before it ships. Submittals on request.
We also sell Grundfos, Franklin Electric, DAB, Goulds and A.Y. McDonald. If TIGERFLOW is not the right fit, we will say so and quote the one that is.
Net-30 for qualified contractor, industrial and municipal accounts. PO and credit applications handled in-house.
Seals, wet ends, motors, flange kits and tanks, cross-referenced by model number.
Common questions from engineers, contractors and facility teams selecting a TIGERFLOW pump.
CD vertical multistage pumps and wet ends carry TIGERFLOW’s one-year guarantee under normal operating conditions, as stated in the CD Series installation, operation and maintenance manual; wearable parts are not covered. Tigercub, Ocelot, T1HS, TMHS, motors and parts are covered for 12 months from the date of purchase.
Yes. CD and T1HS pumps are certified to NSF/ANSI 61 and NSF/ANSI 372 and are cULus Listed. The Tigercub is a UL / cUL listed packaged pumping system built on a CD pump.
All three are in-line vertical multistage pumps with cartridge seals and stainless hydraulics. The CD ships with ANSI Class 300 flanges and a 362 psi maximum working pressure, and carries NSF/ANSI 61 and 372 plus cULus. Grundfos CR offers NPT oval flanges and single-phase builds to larger frames; Franklin VR offers all-316 stainless wetted parts and ODP motors.
No. Fill and vent the CD before it starts and never run it dry or against a closed valve. The Ocelot 25 and Ocelot 60 are the self-priming TIGERFLOW pumps, 9 ft standard and up to 25 ft depending on installation conditions.
A complete pump ships with the TEFC motor coupled to the pump end. A wet end is the pump end only, for a customer who already has a good NEMA C-face motor or is replacing a worn pump end. Match the motor frame and horsepower to the wet end model.
The Ocelot 25 runs on 120V and adds 39 psi at 13 GPM, which covers most single homes on city water. The Ocelot 60 runs on 208-230V single or three phase and adds 61 psi at 35 GPM, for larger homes and light commercial use.
A CD vertical multistage pump and TEFC motor on a stainless base and manifold, a variable frequency drive, a UL 508A listed disconnect panel, a non-slam stainless check valve, low suction alarm, gauges, vibration isolators and union-ball valves, factory tested as one unit. The expansion tank and thermal purge valve are options.
362 psi. Inlet pressure plus the pump’s shut-off pressure must stay below that figure. The T1HS end suction pump is rated to 115 psi.
CD1, CD3 and CD5 have single-phase builds: CD1, CD3 and CD5 up to 2 HP at 115/230V, and CD3 and CD5 at 3 HP on 230V. CD10 and larger are three phase, 230/460V.
Send your flow, the pressure you need, the inlet pressure and the power available. We will reply the same day with a sized selection, accessories and ship date.