TIGERFLOW CD series vertical multistage pumps

TIGERFLOW Pumps and Booster Systems

TIGERFLOW pumps and booster systems, sold and supported by Watermain Supply.
CD vertical multistage pumps in ten series, CD1 to CD85: 1/2 to 50 HP, up to 572 GPM and 807 ft of head, 362 psi maximum working pressure.
Stainless impellers, cartridge seals and premium-efficiency TEFC motors; NSF/ANSI 61 and 372, cULus Listed.
Tigercub simplex boosters package a CD pump with a VFD and UL 508A panel for boost up to 305 psi.
Ocelot 25, Ocelot 60 and Ocelot Duplex variable speed boosters cover homes and light commercial buildings to 144 GPM.
Also T1HS stainless end suction pumps, TMHS pumps, CD wet ends, motors and seals. Same-day quote: call 1-888.510.4036.

37 products
Sort by:
Best selling
Sort by:
Best selling
TIGERFLOW TMHS Multistage Centrifugal Pump - NPT Threaded Ports
TIGERFLOW TMHS Multistage Centrifugal Pump - NPT Threaded Ports

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW TMHS Multistage Centrifugal Pump - NPT Threaded Ports

Price
From $728.02
TIGERFLOW Tigercub Thermal Purge Valve - 1/4 in, 400 PSI
TIGERFLOW 1/4 in stainless thermal purge valve, PN 3200018898

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub Thermal Purge Valve - 1/4 in, 400 PSI

Price
From $532.55
TIGERFLOW Tigercub and Ocelot Diaphragm Expansion Tank - 150 PSI
Amtrol ST-5 2 gallon expansion tank for TIGERFLOW Tigercub booster

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub and Ocelot Diaphragm Expansion Tank - 150 PSI

Price
From $167.32
TIGERFLOW Tigercub CD5 Simplex Variable Speed Booster System
TIGERFLOW Tigercub CD5 simplex variable speed booster system with VFD and disconnect

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub CD5 Simplex Variable Speed Booster System

Price
From $7,679.92
TIGERFLOW Tigercub CD3 Simplex Variable Speed Booster System
TIGERFLOW Tigercub CD3 simplex variable speed booster system with VFD and disconnect

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub CD3 Simplex Variable Speed Booster System

Price
From $7,941.31
TIGERFLOW Tigercub CD20 Simplex Variable Speed Booster System
TIGERFLOW Tigercub CD20 simplex variable speed booster system with VFD and disconnect

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub CD20 Simplex Variable Speed Booster System

Price
From $11,021.47
TIGERFLOW Tigercub CD15 Simplex Variable Speed Booster System
TIGERFLOW Tigercub CD15 simplex variable speed booster system with VFD and disconnect

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub CD15 Simplex Variable Speed Booster System

Price
From $10,242.02
TIGERFLOW Tigercub CD10 Simplex Variable Speed Booster System
TIGERFLOW Tigercub CD10 simplex variable speed booster system with VFD and disconnect

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Tigercub CD10 Simplex Variable Speed Booster System

Price
From $8,627.87
TIGERFLOW TEFC NEMA C-Face Pump Motor - 2-Pole, 3500 RPM, 60 Hz
TIGERFLOW TEFC NEMA C-face pump motor with conduit box

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW TEFC NEMA C-Face Pump Motor - 2-Pole, 3500 RPM, 60 Hz

Price
From $411.09
TIGERFLOW T1HS Stainless Steel End Suction Centrifugal Pump - NSF 61/372
TIGERFLOW T1HS stainless steel end suction centrifugal pump with TEFC motor

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW T1HS Stainless Steel End Suction Centrifugal Pump - NSF 61/372

Price
From $1,074.57
TIGERFLOW Ocelot Duplex Variable Speed Booster System - Lead-Lag
TIGERFLOW Ocelot duplex booster skid, two pumps with stainless manifolds

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Ocelot Duplex Variable Speed Booster System - Lead-Lag

Price
$8,798.06
TIGERFLOW Ocelot Duplex Booster Accessory - Flange Adapters and Gauge
TIGERFLOW Ocelot Duplex booster system, the skid these flange adapters and gauge fit

TIGERFLOW

Free Shipping $499 or more

TIGERFLOW Ocelot Duplex Booster Accessory - Flange Adapters and Gauge

Price
From $80.97

TIGERFLOW Pumps and Booster Systems

TIGERFLOW Systems · Pumps and Booster Systems

TIGERFLOW Pumps
CD Vertical Multistage, Tigercub and Ocelot Boosters

Stainless steel vertical multistage pumps from 1/2 to 50 HP, packaged Tigercub simplex booster systems with a variable frequency drive, and self-priming Ocelot variable speed boosters for homes and light commercial buildings. Every selection is checked against TIGERFLOW’s published curve before it ships.

TIGERFLOW CD series vertical multistage pumps, small and large frames
10 SeriesCD1 to CD85
572 GPMMax flow, CD85
807 ftMax head, CD10
362 psiCD max working pressure
NSF 61 / 372cULus listed

TIGERFLOW Systems builds packaged booster systems and the CD vertical multistage pump family that runs inside them. The CD is an in-line pump with laser-welded stainless steel impellers and chambers, a cartridge mechanical seal and a premium-efficiency TEFC motor, in ten flow classes from 4.4 to 374 GPM nominal. Around it TIGERFLOW offers the Tigercub simplex booster, the Ocelot 25, Ocelot 60 and Ocelot Duplex variable speed boosters, the T1HS stainless end suction pump and the TMHS threaded multistage pump.

Watermain Supply lists the full TIGERFLOW range: complete CD pumps and wet ends, Tigercub systems, Ocelot boosters, T1HS and TMHS pumps, TEFC replacement motors, seals, flange kits and tanks. Send your flow, pressure and power and we will reply the same day with a sized selection. Call 1-888.510.4036. Genuine TIGERFLOW equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.

Will a TIGERFLOW Pump Work for Your Job?

The four questions buyers ask first, answered from TIGERFLOW’s published data.

Warranty

CD pumps and wet ends carry TIGERFLOW’s one-year guarantee under normal operating conditions, per the CD Series manual; wearable parts are excluded. Tigercub, Ocelot, T1HS, TMHS, motors and parts are covered for 12 months from the date of purchase.

Built to Last

Hydraulically balanced stainless impellers and guide vanes, stamped and laser-welded on robotic equipment. A cartridge seal in carbon, silicon carbide and Viton comes out as one piece, and the TEFC motors reach a Minimum Efficiency Index of up to 0.7.

The Fit Limits

CD: 362 psi maximum working pressure, liquid 5°F to 248°F as a guide, ANSI Class 300 flanges 1-1/4 to 4 in, fill and vent before start. T1HS: 115 psi, 14°F to 185°F. Ocelot: self-priming to 9 ft, water to 167°F.

Size It Now

Enter flow and pressure and the calculator returns the pumps that hold your duty point.

Run the Calculator

Or send the numbers: sales@watermainsupply.com · 1-888.510.4036

CD Cartridge Seal Replacement

TIGERFLOW’s walkthrough of the cartridge seal swap on a CD pump, the most common service job on a vertical multistage pump.

CD cartridge mechanical seal replacement

The TIGERFLOW Range

Three families cover most jobs: the CD pump on its own, the CD packaged as a Tigercub booster, and the Ocelot for homes and light commercial buildings.

TIGERFLOW CD vertical multistage pump with TEFC motor

CD Vertical Multistage Pumps

Ten flow classes, 1/2 to 50 HP

572 GPMMax flow, CD85
807 ftMax head, CD10
362 psiMax working
Class 300ANSI flanges

In-line suction and discharge on a common base, stacked stainless impellers and a NEMA TC-frame TEFC motor on top. More stages give more head at the same flow. Sold complete with motor or as a wet end.

  • CD1 to CD85, 4.4 to 374 GPM nominal
  • 304/316 stainless impellers and chambers; cast iron or 316 head and base
  • Cartridge seal: carbon / silicon carbide / Viton
  • NSF/ANSI 61 and 372, cULus Listed
Best forPressure boosting, boiler feed, fire-system jockey pumps, HVAC circulation, industrial and municipal water, irrigation.
View CD Pumps
TIGERFLOW Tigercub simplex booster system dimension drawing

Tigercub Simplex Booster

A CD pump, drive and panel on one base

305 psiMax boost, CD5
154 GPMMax flow, CD20
1 to 7-1/2HP
UL / cULPackaged system

A CD3, CD5, CD10, CD15 or CD20 pump on a stainless base and manifold with a variable frequency drive and a UL 508A listed disconnect panel, prefabricated and factory tested. The drive holds constant pressure as demand changes.

  • Non-slam stainless check valve and low suction alarm
  • Liquid-filled gauges and vibration isolators
  • Union-ball valves on suction and discharge
  • 208-230V 1Ph; 208-230V or 460V 3Ph
Best forApartment buildings, hotels, municipal sites and shopping centers that need high boost from one packaged pump.
View Tigercub Systems
TIGERFLOW Ocelot 60 variable speed booster pump

Ocelot Variable Speed Boosters

Self-priming, permanent magnet motor

77 GPMMax flow, Ocelot 60
99 psiMax boost
9 ftSelf-priming
IPX6Outdoor cover

Variable speed boosters with an integrated drive, built-in expansion tank and check valves on suction and discharge, in a 304 stainless pump body. Low-flow detection slows or stops the pump when demand drops.

  • Ocelot 25: 1 HP, 120V, 24 GPM max
  • Ocelot 60: 2 HP, 208-230V 1Ph or 3Ph, 77 GPM max
  • Ocelot Duplex: two Ocelot 60, lead-lag, 144 GPM max
  • Water to 167°F
Best forHomes on low city pressure, tank or cistern supply, and multifamily or light commercial buildings.
View Ocelot 60

Single Pumps, End Suction and Wet Ends

Also in the range: the TMHS multistage pump, six series from 1/2 to 10 HP with NPT threaded ports and an IP55 TEFC motor.

CD Series at a Glance

The model number is the nominal flow in cubic metres per hour. Pick the series whose flow range covers your duty, then the stage count that gives the head.

Series Nominal GPM Max GPM Max head (ft) HP Power Flanges, Class 300 Pump end
CD1 4.4 On request On request 1/2 to 2 1Ph or 3Ph 1-1/4 in Wet end
CD3 13 22 643 3/4 to 5 1Ph or 3Ph 1-1/4 in Wet end
CD5 22 44 705 1 to 7-1/2 1Ph or 3Ph 1-1/4 in Wet end
CD10 44 74 807 2 to 15 3Ph 2 in Wet end
CD15 66 127 784 5 to 25 3Ph 2 in Wet end
CD20 88 154 666 5 to 25 3Ph 2 in Wet end
CD32 141 211 462 7-1/2 to 20 3Ph 2-1/2 in Wet end
CD42 185 286 453 7-1/2 to 40 3Ph 3 in Wet end
CD65 286 440 446 15 to 40 3Ph 4 in Wet end
CD85 374 572 540 15 to 50 3Ph 4 in Wet end

Max GPM is where TIGERFLOW’s curve ends; max head is the shut-off head of the tallest model in the series. Power: 1Ph builds are 115/230V to 2 HP and 230V at 3 HP; 3Ph builds are 230/460V. CD1 curves are supplied by TIGERFLOW on request. Every series page carries the full model table in psi at four flows.

Quick rule. Divide the series number by 0.227 for nominal GPM. Choose the series whose nominal flow sits at or just above your duty, then the fewest stages that clear the required head with margin at that flow.

TIGERFLOW vs Grundfos, Franklin Electric and DAB

We sell every line below, so we can be straight about fit. Specifications are taken from our own product pages for each brand.

Mid-size vertical multistage pumps

Specification TIGERFLOW CD10 Grundfos CR 10 Franklin Electric 10VR
Nominal flow 44 GPM 53.3 GPM rated 60 GPM at BEP
Max head, tallest model 807 ft 817 ft 2 to 17 stages
Motor range 2 to 15 HP TEFC 3/4 to 15 HP TEFC 1-1/2 to 15 HP, ODP or TEFC
Single phase No, 3Ph only on CD10 Yes, to 3 HP Yes, to 7-1/2 HP
Wetted materials 304/316 stainless impellers and chambers; cast iron or 316 head and base Cast iron head and base; other wetted parts 304 stainless 316 stainless throughout (N version)
Connections 2 in ANSI Class 300 flanges 2 in NPT oval (232 psi) or 2 in ANSI 250 lb (362 psi) 2 in round flange
Max working pressure 362 psi 232 psi oval; 362 psi ANSI Per flange and piping rating
Liquid temperature 5°F to 248°F guide −4°F to 248°F (HQQE seal) 14°F to 248°F
Seal Cartridge: carbon / SiC / Viton Cartridge HQQE or HQQV Type 1 cartridge: graphite / SiC / EPDM
Drinking water NSF/ANSI 61 and 372; cULus NSF/ANSI 61 NSF/ANSI 61 and 372

Verdict. The CD10 matches the CR 10 on maximum head and on the 362 psi rating, and comes with Class 300 flanges as standard and NSF/ANSI 372 plus cULus on the pump. Grundfos CR 10 is the pick when you need NPT oval flanges or a single-phase motor to 3 HP. Franklin 10VR wins where the water calls for 316 stainless throughout or the job needs a single-phase motor to 7-1/2 HP or an ODP motor.

Residential and light commercial boosters

Specification TIGERFLOW Ocelot 25 TIGERFLOW Ocelot 60 DAB Esybox Mini3 DAB Esybox
Max flow 24 GPM 77 GPM 22 GPM 31.7 GPM
Max head 164 ft (70 psi) 230 ft (99 psi) 183 ft (79 psi) 213 ft (92 psi)
Motor 1 HP 2 HP 1.1 HP (P1) 2.1 HP (P1)
Power 120V 1Ph 208-230V 1Ph or 3Ph 115-127V or 208-240V 1Ph 230V 1Ph
Connections 1 in NPT 2 in NPT 1 in NPT 1 in NPT
Self-priming 9 ft standard, to 25 ft 9 ft standard, to 25 ft 26 ft 26 ft
Pump body 304 stainless 304 stainless Glass-filled polypropylene Technopolymer
Water temperature 32°F to 167°F 32°F to 167°F 32°F to 104°F To 104°F
Multi-pump Single unit Ocelot Duplex skid, lead-lag Pairs with one more, wireless Up to four, wireless
App None None H2D app H2D app
Weight 17.6 lb 53 lb 32.2 lb 59.5 lb
Warranty 12 months from purchase 12 months from purchase 24 months from purchase 24 months from purchase

Verdict. The Ocelot 60 carries more than twice the flow of the Esybox, 77 against 31.7 GPM, runs on three-phase power as well as single phase, and takes water to 167°F in a stainless body. The Esybox and Mini3 lead on warranty (24 months), suction lift (26 ft), app control and wireless grouping. The Ocelot 25 is the choice when only 120V is available and the job needs a stainless pump body.

Which TIGERFLOW Pump Do You Need?

Typical selections by job. Demand figures are starting points; send us the duty for an engineering-led selection.

Application Typical duty Recommended Notes
Single home on low city pressure, 120V only Up to 13 GPM at 39 psi boost Ocelot 25 Self-priming; works from a tank or cistern too.
Large home or light commercial, 208-230V Up to 35 GPM at 61 psi boost Ocelot 60 Single or three phase; 2 in NPT.
Multifamily that needs a standby pump Up to 70 GPM at 61 psi boost Ocelot Duplex Two Ocelot 60 pumps, lead-lag with alternation.
Commercial building that needs high boost 22 to 154 GPM, boost to 305 psi Tigercub CD3 to CD20 Simplex; add the expansion tank and purge valve.
Boiler feed, RO, wash-down, industrial boosting 4.4 to 374 GPM nominal CD complete pump Class 300 flanges; NPT companion flange kits available.
Worn pump end on a good motor Same model as installed CD wet end Match motor frame and HP.
Transfer, circulation or irrigation at low head 10 to 92 GPM, up to 56 psi T1HS end suction 304 stainless, 115 psi max working pressure.
Small threaded multistage replacement 1/2 to 10 HP TMHS NPT threaded ports; send the old nameplate.

Sizing a CD Pump

Two numbers pick the pump: the flow you need and the pressure the pump must add at that flow.

1. Pressure the pump must add

Pressure needed at the outlet + 0.433 psi per foot of lift to the highest point + friction losses − pressure already at the pump inlet. Convert to feet of head by multiplying psi by 2.31.

2. Flow

Use the peak simultaneous demand, not the total connected load. Then pick the series whose nominal flow sits at or a little above your duty.

TIGERFLOW CD10 performance curves, head versus flow by stage count
Worked example: 40 GPM at 130 psi of added pressure. 130 psi × 2.31 = 300 ft of head. 40 GPM is inside the CD10 range (44 GPM nominal). On the CD10 curves, the CD10-6 adds 278 ft at 40 GPM, which falls short; the CD10-7 adds 330 ft, about 142 psi, a 12 psi margin, on a 7-1/2 HP motor. Its shut-off head is 371 ft, 160 psi, so with 40 psi at the inlet the casing sees about 200 psi, well inside the 362 psi limit.

3. Check the limits

Inlet pressure plus shut-off pressure below 362 psi. Never run against a closed valve or below the minimum flow. Fill and vent before start; a suction lift works only where NPSH available exceeds NPSH required. Confirm the power: CD10 and larger are three phase.

Booster Sizing CalculatorPressure Tank Calculator

What Sets TIGERFLOW Apart

The construction details that matter on an installation.

Laser-Welded Stainless Hydraulics

Impellers and guide vanes are stamped and laser-welded on robotic equipment and hydraulically balanced, for consistent clearances and lower axial thrust.

Cartridge Seal on Every CD

The carbon, silicon carbide and Viton seal comes out as one cartridge, so a seal change is a short job without disturbing the hydraulics.

Premium-Efficiency TEFC Motors

Standard on every complete CD pump, with a Minimum Efficiency Index up to 0.7 on the pump end.

Class 300 Flanges

ANSI Class 300 flanged suction and discharge, in line, 1-1/4 to 4 in. NPT companion flange kits in 304 stainless or A105 carbon steel are listed separately.

Packaged and Listed

The Tigercub is prefabricated and factory tested as one UL / cUL listed packaged pumping system with a UL 508A listed disconnect panel.

Permanent Magnet Boosters

The Ocelot pairs a permanent magnet motor with an integrated drive; the pump slows as demand falls and stops at no flow.

Stainless End Suction

The T1HS has a 304 stainless pump body, diffuser and impeller, closed-coupled to an IP55 / NEMA 4 TEFC motor.

Drinking Water Certified

CD and T1HS pumps are certified to NSF/ANSI 61 and NSF/ANSI 372 and are cULus Listed.

TIGERFLOW Parts and Accessories

Order them with the pump so the job ships together.

Also listed: CD cartridge mechanical seals, NPT companion flange kits, CD connection options and Ocelot Duplex accessories.

Why Buy TIGERFLOW from Watermain Supply

Engineering-Led Sizing

Send the duty and we select the series, stage count and motor from TIGERFLOW’s published curves, with the margin shown.

Same-Day Quote

Flow, pressure and power in the morning; a sized selection, accessories and ship date back the same day.

We Verify Your Duty Point

Every order is checked against the curve for your flow, inlet pressure and set point before it ships. Submittals on request.

Multi-Brand Honesty

We also sell Grundfos, Franklin Electric, DAB, Goulds and A.Y. McDonald. If TIGERFLOW is not the right fit, we will say so and quote the one that is.

Account Terms Available

Net-30 for qualified contractor, industrial and municipal accounts. PO and credit applications handled in-house.

Parts and Aftermarket

Seals, wet ends, motors, flange kits and tanks, cross-referenced by model number.

Frequently Asked Questions

Common questions from engineers, contractors and facility teams selecting a TIGERFLOW pump.

What warranty comes with TIGERFLOW pumps?

CD vertical multistage pumps and wet ends carry TIGERFLOW’s one-year guarantee under normal operating conditions, as stated in the CD Series installation, operation and maintenance manual; wearable parts are not covered. Tigercub, Ocelot, T1HS, TMHS, motors and parts are covered for 12 months from the date of purchase.

Are TIGERFLOW pumps approved for drinking water?

Yes. CD and T1HS pumps are certified to NSF/ANSI 61 and NSF/ANSI 372 and are cULus Listed. The Tigercub is a UL / cUL listed packaged pumping system built on a CD pump.

How does the TIGERFLOW CD compare with Grundfos CR and Franklin Electric VR?

All three are in-line vertical multistage pumps with cartridge seals and stainless hydraulics. The CD ships with ANSI Class 300 flanges and a 362 psi maximum working pressure, and carries NSF/ANSI 61 and 372 plus cULus. Grundfos CR offers NPT oval flanges and single-phase builds to larger frames; Franklin VR offers all-316 stainless wetted parts and ODP motors.

Does a CD pump prime itself?

No. Fill and vent the CD before it starts and never run it dry or against a closed valve. The Ocelot 25 and Ocelot 60 are the self-priming TIGERFLOW pumps, 9 ft standard and up to 25 ft depending on installation conditions.

What is the difference between a complete CD pump and a CD wet end?

A complete pump ships with the TEFC motor coupled to the pump end. A wet end is the pump end only, for a customer who already has a good NEMA C-face motor or is replacing a worn pump end. Match the motor frame and horsepower to the wet end model.

Which TIGERFLOW booster is right for a house?

The Ocelot 25 runs on 120V and adds 39 psi at 13 GPM, which covers most single homes on city water. The Ocelot 60 runs on 208-230V single or three phase and adds 61 psi at 35 GPM, for larger homes and light commercial use.

What does a Tigercub booster system include?

A CD vertical multistage pump and TEFC motor on a stainless base and manifold, a variable frequency drive, a UL 508A listed disconnect panel, a non-slam stainless check valve, low suction alarm, gauges, vibration isolators and union-ball valves, factory tested as one unit. The expansion tank and thermal purge valve are options.

What is the maximum working pressure of a CD pump?

362 psi. Inlet pressure plus the pump’s shut-off pressure must stay below that figure. The T1HS end suction pump is rated to 115 psi.

Can a CD pump run on single-phase power?

CD1, CD3 and CD5 have single-phase builds: CD1, CD3 and CD5 up to 2 HP at 115/230V, and CD3 and CD5 at 3 HP on 230V. CD10 and larger are three phase, 230/460V.

Ready to Size Your TIGERFLOW Pump?

Send your flow, the pressure you need, the inlet pressure and the power available. We will reply the same day with a sized selection, accessories and ship date.

Technical data on this page is taken from TIGERFLOW Systems product literature (CD Series catalog 2023 and manual, Tigercub catalog 2022, T1HS 2022, Ocelot brochure April 2025) and is subject to change by the manufacturer. Confirm against the current installation manual before specifying.
TIGERFLOW, CD, Tigercub, Ocelot, T1HS and TMHS are trademarks of TIGERFLOW Systems, LLC; Grundfos and CR of Grundfos Holding A/S; Franklin Electric and VR of Franklin Electric Co., Inc.; DAB, Esybox and Esybox Mini3 of DAB Pumps S.p.A. All are used here for product identification only.
Watermain Supply is a DBA of E4 Industrial LLC, an independent industrial supplier based in Houston, Texas.