Year-round water at the barn, pasture, garden and wash-down area. Campbell Heavy Duty, Compact and Sanitary yard hydrants and wall faucets, Monitor Magnum spool-valve hydrants, and the parts to rebuild them.

A frost-proof yard hydrant shuts off at a valve buried below the frost line, then drains the water standing in the riser so nothing is left above ground to freeze. The bury depth is the distance from grade to the supply line and has to reach below the local frost line. Wall faucets do the same job through the wall of a heated building.
Send the frost depth, the water use and the supply size to sales@watermainsupply.com or call 1-888.510.4036 and we will pick the hydrant. All products are genuine, factory-new equipment in original manufacturer packaging, sold and supported by Watermain Supply, an independent industrial supplier.
Three things decide the hydrant.
Choose a depth that puts the valve below your frost line. Campbell YH and CYH run 1 to 8 ft, the Sanitary 1 to 6 ft and the Monitor Magnum 1 to 4 ft.
For a potable supply or where code forbids drain-back to the soil, use the Campbell Sanitary. The Monitor Magnum is not for potable water.
Both brands offer lead free versions; the option is on each listing.
Work out flow and head in a few minutes, or send the duty to 1-888.510.4036 or sales@watermainsupply.com.
Well and Irrigation CalculatorAll CalculatorsWatermain Supply is an Authorized Campbell Manufacturing Distributor.

YH Series
Cast iron head and handle for farm, stock watering and domestic use. The valve shuts off below the frost line and a bleeder drains the riser so the head will not freeze.

CYH Series
Same internals as the Heavy Duty in a compact head: below-frost shutoff, self-draining bleeder, one-piece Buna-N plunger and snap-lock handle.

CSYH Series
Drains into a sealed canister instead of the soil, so no ground water reaches the supply; venturi action empties the canister when opened. Stainless construction for potable water.

WF-A, WF-B, AWF-A
Wall hydrants that shut off inside the heated wall: copper or FPT inlets, anti-siphon models and brass vacuum breakers.

YH Heavy Duty
Heads, plungers, links, packing, nuts, hose adapters and the HPK-1 kit for YH Heavy Duty hydrants. Many parts also fit the Compact.

HP-13
Rod with plunger, extension and coupling, ordered by the hydrant bury depth.
Cast iron and stainless spool-valve yard hydrants.
Watermain Supply is an Authorized Monitor Distributor. The Magnum uses a balanced spool valve in place of a plunger and rod, so there is nothing to adjust and routine service is three O-rings.

Cast iron, spool valve
Balanced spool-valve hydrant with a brass valve body, acetal spool and 3/4 in Sch. 80 PVC wet pipe. No packing nut, valve rod or linkage to adjust; routine service is three standard O-rings.

Stainless stand pipe
The same balanced spool valve as the cast iron Magnum with a 1-1/2 in stainless steel stand pipe for added corrosion resistance.
How the two hydrant lines differ.
| Campbell | Monitor Magnum | |
|---|---|---|
| Valve design | Plunger valve below frost line, bleeder drains the riser | Balanced spool valve; no packing nut, rod or linkage |
| Bury depths | 1 to 8 ft (YH, CYH); 1 to 6 ft (Sanitary CSYH) | 1 to 4 ft |
| Potable water | Sanitary CSYH with sealed canister | Not for potable water |
| Lead free | Standard or lead free | Standard or lead-free (NSF/ANSI 372) |
| Service | Heads, plungers, packing, rods and risers listed | Three standard O-rings |
| Wall faucets | Frostproof wall faucets, anti-siphon models | Not offered |
Quick rule. Campbell for deep frost lines, potable supply (Sanitary) and wall faucets; Monitor Magnum for a spool valve with nothing to adjust, at bury depths to 4 ft.
Start from the job.
| Job | Choose |
|---|---|
| Farm, livestock, hard use | Campbell Heavy Duty YH or Monitor Magnum |
| Home and garden | Campbell Compact CYH |
| Potable water, sanitary code | Campbell Sanitary CSYH |
| Frost line deeper than 4 ft | Campbell YH or CYH, up to 8 ft bury |
| Corrosive soil or wash-down | Monitor Magnum Stainless |
| Hose bibb on a heated building | Campbell frostproof wall faucet |
| Leaking or stiff Campbell hydrant | Campbell replacement parts, rods and risers |
Quick rule. Bury depth at or below the frost line; when in doubt, go one size deeper.
Measure first, then pick.
Sizing the pump that feeds it? Use the Well and Irrigation Calculator or see all calculators.
More well and plumbing collections.
Across both lines.
The valve closes where it cannot freeze.
The riser empties after each use.
Campbell CSYH keeps soil water out of the supply.
Monitor Magnum has no packing nut or rod to adjust.
Campbell heads, plungers, packing, rods and risers.
Lead free versions in both brands.
Send the frost depth and the water use. We pick the hydrant and bury depth before you order.
We list two hydrant brands. If one fits your job better, we will say so.
Contractor, driller, mechanical and municipal accounts on approved credit. Ask us to set one up.
Campbell repair parts, rods and risers are listed beside the hydrants.
Hydrant, pipe, fittings and pump on one order.
We size, quote and support from Houston for contractors, engineers, drillers and utilities.
Pick the depth that puts the valve at or below the local frost line. If you are between sizes, go one deeper.
The Campbell Sanitary CSYH, which drains into a sealed canister instead of the soil. The Monitor Magnum is not for potable water.
Campbell covers deeper bury depths, a sanitary model and wall faucets. The Magnum uses a balanced spool valve with nothing to adjust and is serviced with three O-rings.
Same Campbell internals. Heavy Duty has a larger cast iron head for farm use; Compact has a smaller head for homes and gardens.
On a Campbell hydrant it is usually a worn plunger; order the plunger or the HPK-1 kit. On a Magnum, replace the O-rings.
Yes. Send the frost depth, water use and supply size to sales@watermainsupply.com or call 1-888-510-4036.
Send the frost depth, or the hydrant model and depth for parts.
Technical data on this page is taken from Campbell and Monitor product literature and is subject to change by the manufacturer. Confirm against the current installation manual before specifying.
Campbell is a trademark of Campbell Manufacturing, Inc. Monitor and Magnum are trademarks of Monitor Manufacturing. Names are used here for product identification only.
Watermain Supply is a DBA of E4 Industrial LLC, an independent industrial supplier based in Houston, Texas.