Frost-Proof Yard Hydrants & Faucets

Frost-proof yard hydrants and wall faucets from Campbell and Monitor: Campbell Heavy Duty, Compact and Sanitary yard hydrants in 1 to 8 ft bury depths, Campbell frostproof wall faucets and rebuild parts, and Monitor Magnum spool-valve hydrants in cast iron and stainless, 1 to 4 ft bury. Standard and lead free versions.

Choose a bury depth below your frost line. For drinking water use the Campbell Sanitary. Send the frost depth and water use, or call 1-888-510-4036, and we will pick the hydrant.

11 products
Sort by:
Most relevant
Sort by:
Most relevant
Monitor Magnum Stainless Steel Frost Proof Yard Hydrant
Monitor Magnum Stainless Steel Frost Proof Yard Hydrant

Monitor

Free Shipping $499 or more

Monitor Magnum Stainless Steel Frost Proof Yard Hydrant

Price
From $475.01
Monitor Magnum Frost Proof Yard Hydrant - Cast Iron
Monitor Magnum Frost Proof Yard Hydrant - Cast Iron

Monitor

Free Shipping $499 or more

Monitor Magnum Frost Proof Yard Hydrant - Cast Iron

Price
From $261.01
Campbell Frostproof Wall Faucet - 4-14 in Length
Campbell Frostproof Wall Faucet - 4-14 in Length

Campbell

Free Shipping $499 or more

Campbell Frostproof Wall Faucet - 4-14 in Length

Price
From $56
Campbell Frostproof Yard Hydrant Replacement Parts - Sanitary
Campbell Frostproof Yard Hydrant Replacement Parts - Sanitary

Campbell

Free Shipping $499 or more

Campbell Frostproof Yard Hydrant Replacement Parts - Sanitary

Price
From $28.36
Campbell Frostproof Yard Hydrant Replacement Parts - Compact
Campbell Frostproof Yard Hydrant Replacement Parts - Compact

Campbell

Free Shipping $499 or more

Campbell Frostproof Yard Hydrant Replacement Parts - Compact

Price
From $34.79
Campbell Frostproof Yard Hydrant Replacement Parts - Heavy Duty
Campbell Frostproof Yard Hydrant Replacement Parts - Heavy Duty

Campbell

Free Shipping $499 or more

Campbell Frostproof Yard Hydrant Replacement Parts - Heavy Duty

Price
From $6.49
Campbell Frostproof Yard Hydrant Riser Pipe (Galvanized) - 1-8 ft Bury
Campbell Frostproof Yard Hydrant Riser Pipe (Galvanized) - 1-8 ft Bury

Campbell

Free Shipping $499 or more

Campbell Frostproof Yard Hydrant Riser Pipe (Galvanized) - 1-8 ft Bury

Price
From $59.85
Campbell Frostproof Yard Hydrant Steel Rod Assembly - 1-8 ft Bury
Campbell Frostproof Yard Hydrant Steel Rod Assembly - 1-8 ft Bury

Campbell

Free Shipping $499 or more

Campbell Frostproof Yard Hydrant Steel Rod Assembly - 1-8 ft Bury

Price
From $73.78
Campbell Sanitary (Potable) Frostproof Yard Hydrant - 1-6 ft Bury
Campbell Sanitary (Potable) Frostproof Yard Hydrant - 1-6 ft Bury

Campbell

Free Shipping $499 or more

Campbell Sanitary (Potable) Frostproof Yard Hydrant - 1-6 ft Bury

Price
From $2,549.92
Campbell Compact Frostproof Yard Hydrant - 1-8 ft Bury
Campbell Compact Frostproof Yard Hydrant - 1-8 ft Bury

Campbell

Free Shipping $499 or more

Campbell Compact Frostproof Yard Hydrant - 1-8 ft Bury

Price
From $247.36
Campbell Heavy Duty Frostproof Yard Hydrant - 1-8 ft Bury
Campbell Heavy Duty Frostproof Yard Hydrant - 1-8 ft Bury

Campbell

Free Shipping $499 or more

Campbell Heavy Duty Frostproof Yard Hydrant - 1-8 ft Bury

Price
From $294.48

Frost-Proof Yard Hydrants & Faucets

Frost-Proof Hydrants and Faucets

Frost-Proof Yard Hydrants and Wall Faucets

Year-round water at the barn, pasture, garden and wash-down area. Campbell Heavy Duty, Compact and Sanitary yard hydrants and wall faucets, Monitor Magnum spool-valve hydrants, and the parts to rebuild them.

Campbell heavy duty frostproof yard hydrant
11Listings
2Brands
1–8 ftBury depth
PartsHeads, rods, risers
LFLead free options

A frost-proof yard hydrant shuts off at a valve buried below the frost line, then drains the water standing in the riser so nothing is left above ground to freeze. The bury depth is the distance from grade to the supply line and has to reach below the local frost line. Wall faucets do the same job through the wall of a heated building.

Send the frost depth, the water use and the supply size to sales@watermainsupply.com or call 1-888.510.4036 and we will pick the hydrant. All products are genuine, factory-new equipment in original manufacturer packaging, sold and supported by Watermain Supply, an independent industrial supplier.

Will It Work for Me?

Three things decide the hydrant.

Bury depth

Choose a depth that puts the valve below your frost line. Campbell YH and CYH run 1 to 8 ft, the Sanitary 1 to 6 ft and the Monitor Magnum 1 to 4 ft.

Drinking water

For a potable supply or where code forbids drain-back to the soil, use the Campbell Sanitary. The Monitor Magnum is not for potable water.

Lead free

Both brands offer lead free versions; the option is on each listing.

Size It Now

Work out flow and head in a few minutes, or send the duty to 1-888.510.4036 or sales@watermainsupply.com.

Well and Irrigation CalculatorAll Calculators

Campbell Hydrants and Faucets

Watermain Supply is an Authorized Campbell Manufacturing Distributor.

Campbell heavy duty frostproof yard hydrant

Campbell Heavy Duty Frostproof Yard Hydrant

YH Series

1–8ft bury
3/4in inlet
Cast ironHead
LFOption

Cast iron head and handle for farm, stock watering and domestic use. The valve shuts off below the frost line and a bleeder drains the riser so the head will not freeze.

  • Bury depth 1 to 8 ft
  • Standard or lead free
  • Brass rod, Kevlar packing
Best for Farms and livestock.
Shop Heavy Duty
Campbell compact frostproof yard hydrant

Campbell Compact Frostproof Yard Hydrant

CYH Series

1–8ft bury
3/4in inlet
CompactHead
LFOption

Same internals as the Heavy Duty in a compact head: below-frost shutoff, self-draining bleeder, one-piece Buna-N plunger and snap-lock handle.

  • Bury depth 1 to 8 ft
  • Standard or lead free
  • 3/4 in brass hose connection
Best for Homes, gardens and barns.
Shop Compact
Campbell sanitary frostproof yard hydrant

Campbell Sanitary Frostproof Yard Hydrant

CSYH Series

1–6ft bury
SealedCanister
SSConstruction
PotableUse

Drains into a sealed canister instead of the soil, so no ground water reaches the supply; venturi action empties the canister when opened. Stainless construction for potable water.

  • Bury depth 1 to 6 ft
  • Standard or lead free
  • Pollution-proof design
Best for Potable supplies and code-required installs.
Shop Sanitary
Campbell frostproof wall faucet

Campbell Frostproof Wall Faucet

WF-A, WF-B, AWF-A

4–14in lengths
CopperOr FPT inlet
AWFAnti-siphon
VBVacuum breakers

Wall hydrants that shut off inside the heated wall: copper or FPT inlets, anti-siphon models and brass vacuum breakers.

  • 4 to 14 in lengths
  • Anti-siphon version
  • Vacuum breakers
Best for Exterior walls of heated buildings.
Shop Wall Faucets
Campbell yard hydrant replacement parts

Campbell Yard Hydrant Replacement Parts

YH Heavy Duty

HP-18Head assembly
HPK-1Parts kit
18Components
PacksSmall parts

Heads, plungers, links, packing, nuts, hose adapters and the HPK-1 kit for YH Heavy Duty hydrants. Many parts also fit the Compact.

  • Complete head HP-18
  • HPK-1 service kit
  • Plungers and packing
Best for Rebuilding a leaking hydrant.
Shop Hydrant Parts
Campbell hydrant steel rod assembly

Campbell Hydrant Steel Rod Assembly

HP-13

7/16in rod
1–8ft depths
HP-5Plunger incl.
YH / CYHFits

Rod with plunger, extension and coupling, ordered by the hydrant bury depth.

  • Includes plunger
  • Extension and coupling
  • YH and CYH
Best for Replacing a bent or broken rod.
Shop Rod Assemblies

Monitor Magnum Hydrants

Cast iron and stainless spool-valve yard hydrants.

Watermain Supply is an Authorized Monitor Distributor. The Magnum uses a balanced spool valve in place of a plunger and rod, so there is nothing to adjust and routine service is three O-rings.

Monitor Magnum cast iron yard hydrant

Monitor Magnum Yard Hydrant

Cast iron, spool valve

1–4ft bury
25+GPM at 4 ft, 30 psi
SpoolBalanced valve
LFOption

Balanced spool-valve hydrant with a brass valve body, acetal spool and 3/4 in Sch. 80 PVC wet pipe. No packing nut, valve rod or linkage to adjust; routine service is three standard O-rings.

  • Standard or lead-free
  • Outlet about 24 in above grade
  • Not for potable water
Best for Barns, pastures and yards where adjustment-free service matters.
Shop Magnum Cast Iron
Monitor Magnum stainless yard hydrant

Monitor Magnum Stainless Yard Hydrant

Stainless stand pipe

1–4ft bury
1-1/2 inSS stand pipe
25+GPM at 4 ft, 30 psi
LFOption

The same balanced spool valve as the cast iron Magnum with a 1-1/2 in stainless steel stand pipe for added corrosion resistance.

  • Standard or lead-free
  • Brass valve body, acetal spool
  • Not for potable water
Best for Corrosive soils and wash-down areas.
Shop Magnum Stainless

Campbell or Monitor?

How the two hydrant lines differ.

Campbell Monitor Magnum
Valve design Plunger valve below frost line, bleeder drains the riser Balanced spool valve; no packing nut, rod or linkage
Bury depths 1 to 8 ft (YH, CYH); 1 to 6 ft (Sanitary CSYH) 1 to 4 ft
Potable water Sanitary CSYH with sealed canister Not for potable water
Lead free Standard or lead free Standard or lead-free (NSF/ANSI 372)
Service Heads, plungers, packing, rods and risers listed Three standard O-rings
Wall faucets Frostproof wall faucets, anti-siphon models Not offered

Quick rule. Campbell for deep frost lines, potable supply (Sanitary) and wall faucets; Monitor Magnum for a spool valve with nothing to adjust, at bury depths to 4 ft.

Which One Do I Need?

Start from the job.

Job Choose
Farm, livestock, hard use Campbell Heavy Duty YH or Monitor Magnum
Home and garden Campbell Compact CYH
Potable water, sanitary code Campbell Sanitary CSYH
Frost line deeper than 4 ft Campbell YH or CYH, up to 8 ft bury
Corrosive soil or wash-down Monitor Magnum Stainless
Hose bibb on a heated building Campbell frostproof wall faucet
Leaking or stiff Campbell hydrant Campbell replacement parts, rods and risers

Quick rule. Bury depth at or below the frost line; when in doubt, go one size deeper.

How to Size and Order

Measure first, then pick.

Frost depth: check the local frost line; the valve sits at the bury depth.
Drain rock: set the base in gravel so the hydrant can drain the riser.
Supply: note the supply line size and pressure; the Magnum is rated over 25 GPM at 4 ft bury and 30 psi.
Rebuild: order Campbell parts by hydrant model and bury depth; rods and risers are depth specific.

Sizing the pump that feeds it? Use the Well and Irrigation Calculator or see all calculators.

Related

More well and plumbing collections.

What You Get

Across both lines.

Below-frost shutoff

The valve closes where it cannot freeze.

Self-draining

The riser empties after each use.

Sanitary option

Campbell CSYH keeps soil water out of the supply.

Spool valve

Monitor Magnum has no packing nut or rod to adjust.

Rebuildable

Campbell heads, plungers, packing, rods and risers.

Lead free

Lead free versions in both brands.

Why Buy From Watermain Supply

Engineering-led sizing

Send the frost depth and the water use. We pick the hydrant and bury depth before you order.

Straight answers across brands

We list two hydrant brands. If one fits your job better, we will say so.

Account terms

Contractor, driller, mechanical and municipal accounts on approved credit. Ask us to set one up.

Parts and aftermarket

Campbell repair parts, rods and risers are listed beside the hydrants.

Whole system in one order

Hydrant, pipe, fittings and pump on one order.

Houston based, Gulf Coast service

We size, quote and support from Houston for contractors, engineers, drillers and utilities.

Frequently Asked Questions

How do I choose bury depth?

Pick the depth that puts the valve at or below the local frost line. If you are between sizes, go one deeper.

Which hydrant can I use for drinking water?

The Campbell Sanitary CSYH, which drains into a sealed canister instead of the soil. The Monitor Magnum is not for potable water.

Campbell or Monitor Magnum?

Campbell covers deeper bury depths, a sanitary model and wall faucets. The Magnum uses a balanced spool valve with nothing to adjust and is serviced with three O-rings.

Heavy Duty or Compact?

Same Campbell internals. Heavy Duty has a larger cast iron head for farm use; Compact has a smaller head for homes and gardens.

My hydrant will not shut off fully. Why?

On a Campbell hydrant it is usually a worn plunger; order the plunger or the HPK-1 kit. On a Magnum, replace the O-rings.

Can you help me choose?

Yes. Send the frost depth, water use and supply size to sales@watermainsupply.com or call 1-888-510-4036.

Need a Hydrant or Parts?

Send the frost depth, or the hydrant model and depth for parts.

Technical data on this page is taken from Campbell and Monitor product literature and is subject to change by the manufacturer. Confirm against the current installation manual before specifying.

Campbell is a trademark of Campbell Manufacturing, Inc. Monitor and Magnum are trademarks of Monitor Manufacturing. Names are used here for product identification only.

Watermain Supply is a DBA of E4 Industrial LLC, an independent industrial supplier based in Houston, Texas.