Campbell sewage pump disconnect systems for submersible sewage and effluent pumps. Lift-out service for wet wells, septic tanks, and lift stations — no need to enter the wet well to service the pump. 1 1/4 in through 3 in discharge.
A sewage pump disconnect lets you lift the pump out of a wet well without entering the well or breaking the discharge piping. Two configurations — guide rail (continuous alignment) and non-guide rail (simpler, less expensive).
Continuous Alignment · Heavy-Duty Lift Stations
Two stainless guide rails run from grade down to a base elbow on the wet-well floor. The pump slides down the rails into a sealed connection on the base. Pull a chain and the pump lifts straight up the rails — no diving, no alignment hassle. Standard for municipal lift stations and commercial sewage.
Simpler Install · Smaller Wet Wells
Eliminates the rails. The pump connects directly to a wall-mounted disconnect plate via a pull rod. Best for residential and light-commercial wet wells where the pump is small enough to lift straight up without rail guidance. Lower cost, faster install, fewer parts.
3 in Heavy-Duty · Municipal
SPD300BA — 3 in brass sewage disconnect with separate foot piece (SD FOOT 1 1/4 LF). Used on larger municipal lift stations and high-flow effluent service. Heavy bronze body for chemical resistance to municipal wastewater. Modular — order disconnect and foot piece separately.
Service Hardware · Brackets · Foot Pieces
Stainless and mild-steel pull rods (PR series) in 2 1/2, 3 1/2, 4 1/2, 5 1/2 ft lengths for non-guide-rail systems. Guide rail brackets (MM-19, MM-14, IGRB3), foot pieces, and check-valve disconnects (CVD5). Bantam concrete sewage adapters (BF-20XA, SF-70XA) for direct-thread sewage applications.
SPDS = complete system (disconnect + foot + brackets). GRD = disconnect only. MGRD = modular disconnect. Match discharge size to your sewage pump outlet.
| Part Number | Discharge | Type | Application |
|---|---|---|---|
| SPDS5 | 1 1/4 in | Complete System | Effluent · small sewage pumps |
| SPDS6 | 1 1/2 in | Complete System | Standard residential / light commercial sewage |
| SPDS6-LF | 1 1/2 in | Complete · Lead-Free .05 max | Potable-adjacent / regulated installs |
| SPDS8 | 2 in | Complete System | Larger sewage pumps · commercial |
| SPDS8-LF | 2 in | Complete · Lead-Free .05 max | Lead-free 2 in commercial |
| SPD300BA | 3 in | Brass Disconnect Only | Municipal lift station · high flow |
| GRD5 | 1 1/4 in | Disconnect Only | Replacement / partial upgrade |
| GRD6 | 1 1/2 in | Disconnect Only | Replacement / partial upgrade |
| GRD8 | 2 in | Disconnect Only | Replacement / partial upgrade |
| MGRD5 | 1 1/4 in | Modular Disconnect | Field-assembled custom installs |
| MGRD6 | 1 1/2 in | Modular Disconnect | Field-assembled custom installs |
| MGRD8 | 2 in | Modular Disconnect | Field-assembled custom installs |
Simpler design for residential and light commercial. Lower cost than guide rail; suitable for smaller wet wells where rail alignment isn't critical.
| Part Number | Discharge | Lead-Free | Application |
|---|---|---|---|
| NGRD5 | 1 1/4 in | Standard | Effluent · small residential sewage |
| NGRD6 | 1 1/2 in | Standard | Residential sewage / sump |
| NGRD6-LF | 1 1/2 in | LF .05 max | Lead-free residential sewage |
| NGRD8 | 2 in | Standard | Larger residential / light commercial |
| NGRD8-LF | 2 in | LF .05 max | Lead-free 2 in commercial |
| CVD5 | 1 1/4 in | w/ check valve | Built-in check valve disconnect |
| BF-20XA | 1 1/4 in | Concrete-set | Sewage adapter for concrete penetration |
| SF-70XA | 2 in | Concrete-set | Larger concrete penetration |
Pull rods lift the pump from the disconnect. Stainless rods are corrosion-immune and standard for sewage; mild steel costs less for sump and effluent.
| Stainless | Mild Steel | Length | Wet Well Depth Range |
|---|---|---|---|
| PR25SS | PR25MS | 2 1/2 ft | Shallow wet wells · sumps |
| PR35SS | PR35MS | 3 1/2 ft | Standard residential |
| PR45SS | PR45MS | 4 1/2 ft | Deeper residential / light commercial |
| PR55SS | — | 5 1/2 ft | Commercial · deep wet wells |
Always specify stainless for sewage and septic service. Mild steel rods rust quickly in raw wastewater — they fail at the worst possible moment, when the pump needs service.
A properly designed disconnect saves hours per pump pull and eliminates confined-space entry — a critical safety win on every wet well.
If the wet well services greywater, septic effluent that may contact potable lines, or any installation where local code mandates LF on wastewater fittings, specify SPDS6-LF or SPDS8-LF. Cost premium is roughly 50% but eliminates code rejection.
Disconnect size = pump discharge size. Don't downsize to save cost — restricting the discharge raises pump head, drops flow, and can overheat the motor. 1 1/2 in pump = SPDS6, 2 in pump = SPDS8.
For sewage, septic, or any wastewater service, mild-steel pull rods rust through within 2–5 years. Stainless costs more upfront but lasts the life of the wet well. The PR series is standard 304 stainless.
The MM-14 standoff bracket holds the guide rails parallel and prevents the pump body from contacting the wet-well wall. Required on every guide-rail install — specify one bracket every 5 ft of rail length.
Properly installed disconnects eliminate the need to enter the wet well for routine pump service — OSHA 1910.146 confined-space entry permits, atmospheric testing, and rescue plans become moot. Disconnects are a worker safety win, not just a convenience.
The CVD5 integrates a check valve into the disconnect — eliminates the separate check valve in the discharge line and reduces leak paths. Specify on residential sewage where space is tight.
Use NGRD6 (1 1/2 in non-guide rail). Match to most residential sewage ejector pumps. Add PR25SS or PR35SS stainless pull rod sized to wet-well depth.
Use SPDK1, SPDK2, SPDK3, or SPDK4 sump discharge kits. Pre-assembled with check valve and union for fast install. Match to your sump pump discharge size.
Use NGRD5 (1 1/4 in) or NGRD6 (1 1/2 in). Effluent pumps are typically smaller than full sewage — non-guide-rail is sufficient. Always stainless pull rod.
Use SPDS6 or SPDS8 guide-rail system. Restaurant, retail, or light commercial wet wells with daily duty cycles. Add MM-14 standoffs every 5 ft of rail.
Use SPDS8 or SPD300BA (3 in brass) with full guide-rail kit. High-cycle, heavy-duty service. Specify lead-free where local code applies.
Use multiple SPDS systems — one per pump. Each disconnect is independent so pumps can be pulled individually for service while the others stay in operation.
Pair guide-rail SPDS with SJE-Rhombus alarm panel. Disconnect enables rapid pump removal and replacement post-flood — critical recovery capability on the Gulf Coast.
Use BF-20XA (1 1/4 in) or SF-70XA (2 in) sewage adapter for concrete-set discharge penetrations. Threaded into a core-drilled hole in the wet-well wall.
Tell us your pump make/model, discharge size, wet-well depth, and whether it's residential, commercial, or municipal. We'll spec the exact Campbell SKUs — disconnect, foot piece, brackets, and pull rod — and ship from Houston same day.