Menu
Davey
Davey
Davey
Australian-built pressure boosting with the Torrium2 controller, all-stainless hydraulics and a 130°F ambient motor rating. Five families covering 14 to 36 gpm and up to 95 psi — sized to your building by our technical desk in Houston.
Davey Water Products is an Australian pump manufacturer whose booster range is built around one idea most of the market still does not use: read flow as well as pressure. A conventional booster runs on a pressure switch, which starts the pump at cut-in and stops it at cut-out, and the gap between those two numbers is what you feel in the shower. Davey’s Torrium2 controller senses pressure and flow together — the pump runs while water is being drawn and stops when it is not, at a cut-out flow of 0.26 gpm.
Five families sit on this page. BT and BIT are Torrium2 boosters for pressurized mains and for cistern supply. DynaDrive and EvoDrive are drive-controlled constant-pressure systems with the tank built in, both of which pair for duty/standby. Torrium2 is the controller on its own, for retrofitting a pump that is sound but whose switch and tank are not.
Genuine Davey equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial distributor. Send your flow, pressure and supply arrangement to 1-888.510.4036 and we will size it against Davey’s published data before you order.
Five things Davey publishes that most booster datasheets do not.
The pump starts on a pressure drop and stops when flow falls below 0.26 gpm. That single design decision is why a Davey booster holds a steady pressure through a shower where a pressure-switch system sawtooths between cut-in and cut-out. It also means no pressure tank and no pressure switch in the installation — two fewer parts, and the two most likely to fail.
After every stop, Torrium2 sets the cut-in point to 80 percent of the last shut-off head. Seasonal supply variation, a main that weakens over the summer, a system that changes as the building does — the controller follows it. Nobody goes back to adjust anything.
304 stainless impellers, casing, backplate, lock nut and stage body; 316 stainless pump shaft; Teflon neck rings; ceramic and carbon seal faces; marine-grade aluminium motor shell with a baked polyester finish. Every wetted part is specified for corrosion resistance, and the pump handles water to 176°F.
Davey publishes the BT motor at a 130°F ambient rating — which it states gives longer life and better tolerance to voltage variation — with IP55 ingress protection, TEFC corrosion-resistant construction and an automatically re-setting thermal overload. In an un-ventilated Texas plant room in August, the ambient rating is the number that matters.
WQA certified to NSF/ANSI 61, listed to UL 778, UL 61800-5-1 and CSA-C22.2 No. 108-14. Davey specifies motor and pump for frequent starts, which is what a demand-led booster does all day and what kills equipment that was not built for it.
No hard wiring on the BT range — a 6 ft cord with a standard NEMA plug, 5-15P on 120V and 6-15P on 240V. The discharge outlet rotates a full 360° so the outlet plumbing runs vertically or at a right angle, and the coupling wrench is in the box.
Match the situation to the family. If none of these is quite it, call us — that is the part we are good at.
| The situation | What is going on | The family |
|---|---|---|
| Weak city pressure | Municipal supply arriving at 20–40 psi, showers falling off when a second fixture opens. The supply is pressurized; it is just not enough. | BT Series |
| Tank, cistern or rainwater | Drawing from stored water that arrives at little or no pressure, on a supply that can be interrupted. | BIT Cistern Series |
| Constant pressure, higher flow | Household, farm, irrigation or turf watering needing steady pressure across the whole flow range, with the tank already in the package. | DynaDrive |
| Quiet, efficient, medium home | Medium-sized home or a café, small office or retail unit where noise matters and demand varies all day. | EvoDrive |
| Below-ground storage tank | Pulling clean water up from a tank below the pump — EvoDrive lifts 13 ft, the BT range 25 ft. | EvoDrive or BT Series |
| Duty / standby redundancy | The installation cannot be down. EvoDrive pairs from one cable for duty/standby or parallel; DynaDrive daisy-chains two pumps in parallel. | EvoDrive or DynaDrive |
| Failed switch, waterlogged tank | The pump is sound but the pressure switch has failed or the tank has lost its charge. Replacing the controller is a smaller job than replacing the set. | Torrium2 controller |
| RO or filtration make-up | Boosting downstream of a reverse osmosis or filtration system that has taken its share of the available pressure. | EvoDrive |
Two Torrium2 boosters, two drive-controlled constant-pressure systems, and the controller on its own.

Pressurized mains · five models
The core Torrium2 booster. All-stainless hydraulics, 130°F ambient motor, IP55, and a controller that needs no tank and no switch. Davey publishes a maximum inlet pressure per model — from 20 psi on the BT20-40 to 60 psi on the BT14-30 — so the model is chosen on inlet as much as on boost.

Tank & cistern supply · three models
The same Torrium2 intelligence configured for stored water — rainwater tanks, cisterns and bore storage where the source arrives at little or no pressure. Dry-run protection and automatic restart are the features that matter on a supply that can empty.

All-in-one constant pressure · 2-year warranty
Pump, controller and pressure tank in one assembly, holding a constant pressure instead of cycling. Horizontal multistage with all hydraulic parts in stainless, impellers on an extended motor shaft, and an air purging valve on the DD60 and DD90. Two units daisy-chain in parallel.

VSD · permanent magnet · 2-year warranty
A variable speed drive and a permanent magnet motor holding one outlet pressure from a dripping tap to full flow, quietly and at low energy. Illuminated touch panel showing operating and set pressure. Two units pair from one cable for duty/standby or parallel, alternating cycles to share the load.

Retrofit · three variants
The controller from the BT and BIT, sold on its own to fit a compatible centrifugal pump. Replaces the pressure switch, the pressure tank and the non-return valve with one unit, and Davey publishes it as having lower head loss than comparable controllers because the internal water pathways are large.
The two axes that decide it: whether the supply arrives pressurized, and whether the installation needs a second pump.
| Family | Supply | Control | Flow | Pressure | Tank | Pairing | Warranty |
|---|---|---|---|---|---|---|---|
| BT Series | Pressurized main | Torrium2, pressure + flow | 14–30 gpm nominal | 40–80 psi boost | Not required | Single unit | 12 months |
| BIT Cistern | Tank, cistern, rainwater | Torrium2, pressure + flow | 14–20 gpm nominal | 30–45 psi nominal | Not required | Single unit | 12 months |
| DynaDrive | Either | Drive, constant pressure | to 36 gpm | to 91 psi head | Built in, 42 psi pre-charge | Two, daisy chain | 24 months |
| EvoDrive | Either, 13 ft lift | VSD, permanent magnet | 28 gpm | 95 psi maximum | Built in, 47–50 psi | Two, duty/standby or parallel | 24 months |
| Torrium2 | Any — retrofit | Pressure + flow | Set by the pump | 15–80 psi setting | Replaces it | n/a | 12 months |
Davey tabulates DynaDrive and EvoDrive as flow at stated pressures. These are the manufacturer’s own figures, not readings off a plot.
| Pressure held | DD15-35NPT | DD60-10NPT | DD90-11NPT |
|---|---|---|---|
| 43 psi | 12 gpm | 16 gpm | 24 gpm |
| 58 psi | 5 gpm | 13 gpm | 19 gpm |
| 73 psi | — | 8 gpm | 9 gpm |
| Maximum head, zero flow | 65 psi | 91 psi | 80 psi |
| Stages | 5 | 6 | 5 |
| Voltage | 110–120V | 220–240V | 220–240V |
| Maximum casing pressure | 116 psi | 145 psi | 145 psi |
Maximum set pressure is 87 psi on all three, but no model holds more than the head it can make — on the DD15-35NPT the 65 psi head is the real ceiling. Source: Davey DynaDrive datasheet DWP1940-6/0625.
| Pressure held | 20 psi | 40 psi | 60 psi | 95 psi |
|---|---|---|---|---|
| Flow — ED16-40NPT | 22 gpm | 16 gpm | 10.5 gpm | 0 |
| Note | — | Best efficiency point | Factory set point | Maximum pressure |
Davey publishes the best efficiency point for EvoDrive rather than leaving it to be derived — 16 gpm at 40 psi. In faucets: from a tank at a 60 psi setting, 10.5 gpm or about five faucets; boosting a 35 psi city main at the same setting, 21 gpm or about ten, based on 2.2 gpm average per outlet running together. Source: Davey EvoDrive datasheet DWP3267-1/1025.
| Model | Nominal duty | Maximum inlet | Maximum boost | Voltage | P1 kW | FLA | Weight |
|---|---|---|---|---|---|---|---|
| BT14-30 | 14 gpm at 30 psi | 60 psi | 40 psi | 120V | 0.92 | 7.80 | 26.50 lbs |
| BT14-45 | 14 gpm at 45 psi | 40 psi | 60 psi | 120V | 0.86 | 7.30 | 25.40 lbs |
| BT20-30 | 20 gpm at 30 psi | 50 psi | 50 psi | 120V | 0.98 | 8.20 | 27.30 lbs |
| BT20-40 | 20 gpm at 40 psi | 20 psi | 80 psi | 220–240V | 1.10 | 4.70 | 27.30 lbs |
| BT30-30 | 30 gpm at 30 psi | 50 psi | 50 psi | 220–240V | 1.44 | 7.00 | 16.25 lbs |
Four checks, in the order that catches the most mistakes.
On the BT range this decides as much as the boost figure does. Davey publishes a maximum inlet pressure per model, and incoming plus added must stay under the 100 psi system limit. A 55 psi main rules out the BT20-40 and the BT14-45 before you look at anything else.
Required boost = target pressure at the highest fixture + 0.433 psi per foot of elevation + friction loss − inlet pressure. A two-story house wanting 45 psi at the top, 22 ft up, with 5 psi of friction and 30 psi arriving: 45 + 9.5 + 5 − 30 = 29.5 psi of boost. A BT14-30 or BT20-30 covers that; the BT20-40 is more pump than the job needs and accepts a lower inlet.
WSFU and Hunter’s curve (IPC Table 604.3) for residential. Davey’s own rule of thumb is useful for a sanity check: about 2.2 to 3 gpm per faucet running at the same time, so a three-bath house with a couple of outlets open lands around 12–16 gpm, not the 30 a fixture-unit count can suggest.
The BT range lifts 25 ft with a good quality foot valve fitted; EvoDrive lifts 13 ft. And pairing is a purchase decision — only DynaDrive and EvoDrive pair, so if the installation may ever need a second pump, that is the fork in the road.
We sell both, so we can be straight about it. These two ranges overlap, and the right answer depends on what the building needs next.
| Consideration | Davey EvoDrive | Davey DynaDrive | DAB Esybox |
|---|---|---|---|
| Control | VSD, permanent magnet motor | Drive, constant pressure | VSD, constant pressure |
| Maximum flow | 28 gpm | 36 gpm | 32 gpm |
| Maximum pressure added | 95 psi | 91 psi | 92 psi at shut-off |
| Self-priming | No — 13 ft lift | No | Yes, to 26 ft |
| Tank | Built in | Built in | Built in, 0.5 gal |
| Maximum units in a group | 2 | 2 | 4, wireless |
| Adding a pump later | Cable, sold separately | Daisy chain | Wireless pairing, no controller |
| Noise | Quiet — permanent magnet | Quiet running | 43 dB published |
| App | None | None | Yes |
| Warranty | 24 months | 24 months | 24 months |
The honest verdict. EvoDrive is the quieter, more efficient machine of the two Davey drives and publishes its best efficiency point, which most manufacturers do not; DynaDrive carries more water and more stages. Where Davey wins outright is the Torrium2 retrofit — there is no DAB equivalent to fitting one controller to a pump you already own. Where DAB wins is growth and self-priming: the Esybox pairs up to four units wirelessly with no controller and no rewiring, and it lifts 26 ft where neither Davey drive is self-priming at all. If the building may outgrow one pump, or the supply is a tank below the pump, look at the DAB Esybox range before you commit. Competitor figures from our own DAB product pages and curve data.
60 Hz models with NPT connections and standard NEMA plugs — 5-15P on 120V, 6-15P on 240V — not an import variant that needs a transformer and an adapter to run.
We hold the published curve and duty-point data for this range. Send inlet pressure, required flow, building height and supply type and you get a sized selection and the data sheet, not a catalogue page.
If Davey is not the right fit, we will say so and quote the one that is — see the comparison above. We supply DAB, Grundfos, Goulds, Franklin Electric and A.Y. McDonald alongside it.
Pump, controller, tank where one is needed and the fittings to go with it, on a single purchase order rather than three vendors and three lead times.
A live technical sales desk in Houston, Monday to Friday, and nationwide delivery.
Net-30 for qualified contractor, property-management and municipal accounts.
What our technical desk gets asked most about this range.
Not on the BT, BIT or Torrium2 — the controller replaces the pressure switch and the tank. DynaDrive and EvoDrive carry a tank inside the package already. On any system with a storage water heater a separate thermal expansion tank is still required at the heater, whatever booster you fit.
Because it adds the most — 80 psi — and incoming plus added has to stay under the 100 psi maximum system pressure. Davey publishes a maximum inlet figure for every model, from 20 psi on the BT20-40 to 60 psi on the BT14-30. Measure your main before choosing on boost.
It reads flow as well as pressure. The pump starts on a pressure drop and stops when flow falls below 0.26 gpm, rather than stopping at a fixed cut-out pressure. It also resets its own cut-in point to 80 percent of the last shut-off head after every stop, so it follows a supply that changes without anyone adjusting it.
Yes, on a compatible centrifugal pump — that is what the standalone variants are for. The controller has to be matched to both the pressure band and the motor rating, so send us the pump make, model and nameplate and we will confirm which variant fits before you order.
DynaDrive daisy-chains two pumps in parallel, and EvoDrive pairs two units for duty/standby or parallel from a single connection cable, alternating cycles to share the load and combining output at peak demand. The BT and BIT are single-unit only. It is a purchase decision, so decide before you order.
The BT range lifts to 25 ft, and Davey requires a good quality foot valve on a lift installation, with the PRIME button held in while the pump establishes prime. EvoDrive lifts to 13 ft. Where the lift is deeper than that, a self-priming machine is the better answer.
Yes. The BT, DynaDrive and EvoDrive ranges are WQA certified to NSF/ANSI 61, and listed to UL 778, UL 61800-5-1 and CSA-C22.2 No. 108-14.
The BT motor carries a 130°F ambient rating, which Davey publishes as giving longer life and better tolerance to voltage variation, with IP55 ingress protection and an automatically re-setting thermal overload. The Torrium2 controller itself is rated to 120°F ambient, which is the lower of the two figures and the one to design against.
Twelve months from the date of purchase as standard, and 24 months on DynaDrive and EvoDrive, which Davey publishes a two-year term for on its own data sheets. Keep your invoice — it is the document a claim is evidenced by.
Possibly. If the building may outgrow one pump, the DAB Esybox pairs up to four units wirelessly with no controller and no rewiring, where the Davey drives cap at two. If the supply is a tank below the pump, the Esybox is self-priming to 26 ft and neither Davey drive is self-priming at all. If you are retrofitting a controller to an existing pump, Davey wins and DAB has no equivalent. Tell us the job and we will say which.
Send inlet pressure, required flow, building height, supply type and whether the installation needs a second pump. We will come back with a sized selection, the data sheet and a lead time — and an honest note if a different brand fits better.