Davey BT Series Booster Pump

GPM: 14 GPM
Pressure: 30 PSI
Phase: Single Phase 110V 60Hz

Product variant with selected options does not exist!

Price
$1,381.20
SKU: BT14-30
Weight : 26.5 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Davey · Booster Pump
Davey BT Series Booster Pump
All-stainless pressure booster with the Torrium2 controller built in — no pressure tank, no pressure switch, no cycling. Five models from 14 to 30 gpm nominal and 40 to 80 psi of boost.
14 – 30 GPM Nominal
40 – 80 PSI Boost
120V & 220-240V 1Ph
Torrium2 Controller
All-Stainless Hydraulics
IP55 · 130°F Ambient
25 ft Suction Lift
WQA to NSF/ANSI 61
Overview

The BT is a robust centrifugal pump fitted with Davey’s Torrium2 water pressure controller, sold as one assembly. Torrium2 reads pressure and flow together rather than pressure alone, so the pump runs while water is being drawn and stops when it is not — which is why the BT holds a seemingly constant pressure where a pressure-switch system hunts between cut-in and cut-out.

Davey specifies it for homes where the incoming municipal supply is inadequate, for underground or surface water supplies, automatic water transfer, installations where the supply may be interrupted, and domestic and light industrial irrigation. All-stainless construction handles water to 176°F.

Installation is plug-in: a 6 ft power cord with a standard NEMA plug — 5-15P on the 120V models, 6-15P on the 240V — and a discharge outlet that rotates a full 360° so the outlet plumbing can run vertically or at a right angle. The coupling wrench is in the box.

Genuine Davey equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial distributor.
12-Month Warranty

Covered for 12 months from the date of purchase.

Single Unit Only

The BT is supplied as a single pump with its controller. Davey does not publish a paired or duty/standby configuration for this series.

Where a building needs a second pump for backup or for more flow, the drive-controlled models do it. The EvoDrive pairs two units in duty/standby or parallel from a single connection cable, and the DynaDrive daisy-chains two pumps in parallel. Choose one of those at purchase if the installation may need redundancy.

The Torrium2 Controller

Constant flow operation — Torrium2 senses pressure and flow together. It starts on a pressure drop and stops when flow falls below 0.26 gpm, which is what removes the cycling a pressure switch gives you in the shower.

Adaptive cut-in pressure — Cut-in is set to 80 percent of the last shut-off head, every stop. The controller follows seasonal supply variation and changing demand without anyone adjusting it.

Low head loss — Large internal water pathways mean Torrium2 costs less head than comparable pressure controllers, so more of what the pump makes reaches the fixture.

Adjustable setting range — Settable from 15 psi to 80 psi.

No pressure tank required — The controller replaces the pressure switch and tank in a conventional booster installation.

Specifications
Model Nominal duty Max inlet pressure Max boost Voltage P1 kW P2 kW FLA LRA Inlet Weight
BT14-30 14 gpm at 30 psi 60 psi 40 psi 120V single phase 0.92 0.73 7.80 38.00 1-1/4 in F 26.50 lbs
BT14-45 14 gpm at 45 psi 40 psi 60 psi 120V single phase 0.86 0.68 7.30 38.00 1 in F 25.40 lbs
BT20-30 20 gpm at 30 psi 50 psi 50 psi 120V single phase 0.98 0.78 8.20 38.00 1-1/4 in F 27.30 lbs
BT20-40 20 gpm at 40 psi 20 psi 80 psi 220-240V single phase 1.10 0.92 4.70 23.00 1 in F 27.30 lbs
BT30-30 30 gpm at 30 psi 50 psi 50 psi 220-240V single phase 1.44 1.12 7.00 23.71 1-1/4 in F 16.25 lbs
Capacity to 45 gpm
Maximum total head 76 psi
Cut-in pressure Adapts to 80% of last shut-off head
Setting range 15 psi minimum, 80 psi maximum
Cut-out flow rate 0.26 gpm
Maximum suction lift 25 ft
Maximum liquid temperature 176°F pump; 158°F at the Torrium2
Maximum ambient temperature 130°F motor; 120°F at the Torrium2
Maximum pump casing pressure 116 psi
Maximum system pressure 100 psi
Outlet 1 in M, rotates 360°
Power connection 6 ft cord, NEMA 5-15P (120V) or NEMA 6-15P (240V)
Motor 2 pole, Class F insulation, IP55, TEFC
Impellers, casing, backplate, lock nut, stage body 304 stainless steel
Pump shaft 316 stainless steel
Neckrings Teflon
Mechanical seal Ceramic stationary, synthetic carbon rotating, 304 stainless spring
O-rings Nitrile rubber
Torrium2 body Glass-filled nylon
Torrium2 check valve Nylon stem assembly, 304 stainless spring, nitrile seal
Motor shell, lantern and endshield Marine grade aluminium, baked polyester finish
Approvals UL 778; UL 61800-5-1; CSA-C22.2 No. 108-14; NSF/ANSI 61 (WQA certified)
Performance — Will It Do What You Need?

The figures below are the pressure this pump adds. That is what a pump curve measures — the impeller does not know what pressure is already on its inlet.

BT14-30 — 14 gpm at 30 psi nominal, 40 psi maximum boost

Flow — GPM 0 5 10 14 20 25 30 39.1
Pressure Added — PSI 40 35 33 30 26 21 16 4
Pressure Added — ft of head 92.4 80.8 76.2 69.3 60 48.5 37 9.2

BT14-45 — 14 gpm at 45 psi nominal, 60 psi maximum boost

Flow — GPM 0 5 10 14 20 25 26.5
Pressure Added — PSI 60 53 48 45 26 9 3
Pressure Added — ft of head 138.6 122.4 110.9 103.9 60 20.8 6.9

BT20-30 — 20 gpm at 30 psi nominal, 50 psi maximum boost

Flow — GPM 0 5 10 15 20 25 30 39.7
Pressure Added — PSI 50 44 39 34 30 23 17 4
Pressure Added — ft of head 115.5 101.6 90.1 78.5 69.3 53.1 39.3 9.2

BT20-40 — 20 gpm at 40 psi nominal, 80 psi maximum boost

Flow — GPM 0 5 10 15 20 22 24 26.5
Pressure Added — PSI 80 70 63 53 40 30 20 5
Pressure Added — ft of head 184.8 161.7 145.5 122.4 92.4 69.3 46.2 11.5

BT30-30 — 30 gpm at 30 psi nominal, 50 psi maximum boost

Flow — GPM 0 5 10 15 20 30 40 51.4
Pressure Added — PSI 50 45 42 39 36 30 24 4
Pressure Added — ft of head 115.5 103.9 97 90.1 83.1 69.3 55.4 9.2

Drawing from a tank, cistern or well — nothing arrives with pressure, so what the pump adds is what you get. Read the table straight through: a BT30-30 delivers about 30 gpm at 30 psi.

Fed by a city main — the pump adds on top of what already arrives, and Davey publishes a maximum inlet pressure per model because incoming plus boost has to stay under the 100 psi system limit. The BT20-40 makes the most boost at 80 psi and therefore accepts the least inlet, 20 psi; the BT14-30 accepts 60 psi inlet and adds 40. Incoming pressure buys you more flow, not more pressure.

Best operating range: 10 to 18 gpm on the 14 gpm models, 15 to 25 gpm on the 20 gpm models and 22 to 38 gpm on the BT30-30. This is where the pump turns the most electricity into water pressure. Ask for more flow than it can deliver at your setting and it runs at full speed continuously, which is where motors and seals wear out. Sizing a booster to the building rather than to the headline numbers is what makes it last.

Zero flow is the shut-off point — a ceiling, not a working point. Davey publishes the family capacity as 45 gpm and maximum total head as 76 psi; the per-model maximum boost figures in the table above are from Davey’s own performance table and govern selection. Curves read from the published plot in the Davey BT Series datasheet DWP0116-4/0323; best operating range is derived from those points, as Davey publishes no efficiency curve for this series.

The Motor

130°F ambient rating — Higher than the usual motor rating, which Davey publishes as giving longer life and better tolerance to voltage variation. That margin is the one that matters in a Houston plant room.

TEFC, corrosion-resistant — Totally enclosed fan-cooled motor built from corrosion-resistant materials, with a marine-grade aluminium shell and endshield.

IP55 — Rated against dust ingress and low-pressure water jets.

Auto-resetting thermal overload — Built-in protection against both high operating temperature and high current draw, resetting itself rather than needing a trip out to the site.

Designed for frequent starts — Motor and pump are specified for frequent starting, which is what a demand-led booster actually does all day.

Fail-safe capacitor — Permanently split P2 capacitor design.

Before You Buy — The Limits That Decide the Fit
Maximum inlet pressure Published per model, from 20 psi on the BT20-40 to 60 psi on the BT14-30. Check yours against the main before selecting on boost alone.
Maximum system pressure 100 psi. Incoming plus added must stay below it.
Suction lift To 25 ft. On a lift installation Davey requires a good quality foot valve, and the system is primed through the priming port with the PRIME button held in.
Power 120V single phase on the BT14-30, BT14-45 and BT20-30; 220-240V single phase on the BT20-40 and BT30-30. Not field-convertible.
Best operating range 10–18 gpm (14 gpm models); 15–25 gpm (20 gpm models); 22–38 gpm (BT30-30).
Pressure tank Not required — Torrium2 replaces the tank and switch. On any system with a storage water heater a separate thermal expansion tank is still required at the heater.
Pairing Single unit only.
Water temperature To 176°F at the pump; the Torrium2 limit is 158°F.
Reading the Model Number

B is the stainless steel booster series, T means Torrium2 equipped, and the two numbers are flow at nominal pressure. BT14-30 is 14 gpm at 30 psi; BT20-40 is 20 gpm at 40 psi.

For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

App & Connectivity

This system has no app or remote connectivity. It runs from the Torrium2 controller and needs no network connection.

You May Also Like