Taco TA horizontal split case pump on base with motor

Split Case Pumps

Taco double suction split case pumps from 1 to 800 HP: TA, HS and GT horizontal split case and TC and TS vertical split case, with 3 to 18 in flanges, 175 psig standard or 300 psig with 250# flanges. Built to order with the impeller trimmed to your duty.

5 products
Sort by:
Most relevant
Sort by:
Most relevant
Taco TS Vertical Split Case Pump - Double Suction, Stainless Impeller
Taco TS vertical split case pump on base with motor

Taco

Free Shipping $499 or more

Taco TS Vertical Split Case Pump - Double Suction, Stainless Impeller

Price
From $12,997.75
Taco TC Vertical Split Case Pump - Double Suction, Stainless Impeller
Taco TC vertical split case pump on base with motor

Taco

Free Shipping $499 or more

Taco TC Vertical Split Case Pump - Double Suction, Stainless Impeller

Price
From $12,997.75
Taco TA Horizontal Split Case Pump - Double Suction, Bronze-Fitted
Taco TA horizontal split case pump on base with motor

Taco

Free Shipping $499 or more

Taco TA Horizontal Split Case Pump - Double Suction, Bronze-Fitted

Price
From $9,826.33
Taco HS Horizontal Split Case Pump - Double Suction, Bronze-Fitted
Taco HS horizontal split case pump on base with motor

Taco

Free Shipping $499 or more

Taco HS Horizontal Split Case Pump - Double Suction, Bronze-Fitted

Price
From $13,383.12
Taco GT Horizontal Split Case Pump - Double Suction, Bronze-Fitted, Large Flow
Taco GT horizontal split case pump on base with motor

Taco

Free Shipping $499 or more

Taco GT Horizontal Split Case Pump - Double Suction, Bronze-Fitted, Large Flow

Price
From $27,826.26

Split Case Pumps

Taco · Double Suction Split Case Pumps

Split Case Pumps 1 to 800 HP, Double Suction

Single-stage, double suction split case pumps for chilled water, condenser water, heating water, pressure boosting and water supply: Taco TA, HS and GT horizontal split case and TC and TS vertical split case pumps, 60 Hz US builds from 1 to 800 HP with 3 to 18 in flanges.

Taco TA horizontal double suction split case pump
5Series
678US Builds
1-800HP
3-18 inFlanges
300 psigWith 250# Flanges

A split case pump takes water into both sides of one impeller and splits its casing along the shaft, so the rotating assembly lifts out for service. The double-entry impeller all but cancels axial thrust, which keeps bearing loads low and lets the pump run long hours at high flow. That is why split case pumps carry the primary chilled water and condenser water loops in hospitals, data centers, campuses and district plants, and the high-flow transfer and supply duties in industry.

Each build on these listings is one pump size at one speed with one motor HP; Taco trims the impeller to your duty point. Send the flow, head, liquid and voltage and we match the build on the Taco curve before you order. Email sales@watermainsupply.com or call 1-888.510.4036. All products are genuine, factory-new equipment in original manufacturer packaging, sold and supported by Watermain Supply, an independent industrial supplier.

Will It Work for My Plant?

The four questions engineers and facility teams ask first, answered from the data on each listing.

Warranty

Set by Taco under its published terms for commercial pumps. Ask us for the Taco terms document with your quote; it states the term and what it covers.

Reliability

Balanced thrust from the double suction impeller, heavy-duty grease-lubricated bearings on TA, a short rigid shaft on HS and a dry shaft on GT. Every casing opens without disturbing the system piping.

Fit

175 psig standard, 300 psig with 250# flanges, liquid to 250°F. Bronze-fitted (TA, HS, GT) or stainless impeller (TC, TS). 1160, 1760 or 3500 RPM, 60 Hz, three-phase motors.

Size It Now

Work out loop flow from the load and ΔT, then the head, with the HVAC Pump Calculator, or send the duty to 1-888.510.4036.

Product Lines

Three body styles: horizontal split for the widest range, vertical split for a small footprint, and the large GT for the biggest loops.

Taco TA horizontal split case pump

TA Series

Horizontal split case, bronze-fitted

1-450HP
3-12 inflanges
1160-3500RPM
194US builds

Taco's core horizontal split case pump. The impeller is designed for low NPSH required and stable performance across its range, and the balanced double-entry design leaves the grease-lubricated bearings little thrust to carry.

  • 18 pump sizes
  • 509 to 7,215 lb
  • The widest speed range of the five series
Best forPrimary chilled and condenser water, and high-flow boosting
View TA
Taco TC vertical split case pump

TC Series

Vertical split case, stainless impeller

2-800HP
5-16 inflanges
1160 or 1760RPM
195US builds

A vertically split, base-mounted pump with top suction and discharge connections that keep the footprint small, and integrally cast feet so the pump can be serviced without disturbing the piping.

  • 22 pump sizes
  • 948 to 7,347 lb
  • Stainless steel impeller
Best forTight plant rooms that still need large flow
View TC
Taco GT large horizontal split case pump

GT Series

Large horizontal split case

30-800HP
12-18 inflanges
1160 or 1760RPM
56US builds

Taco's largest split case pump. A dry shaft design keeps the pumped fluid off the shaft, and integrally cast feet let the casing be serviced without disturbing the piping connections.

  • 6 pump sizes
  • 4,037 to 13,161 lb
  • Bronze-fitted
Best forDistrict plants, campus loops and the largest data center plants
View GT

Also in the range

Watermain Supply is an Authorized Taco Distributor.

Compare the Five Series

Ranges are the limits across each listing, not one duty point. The curve on each listing shows what one build does at your flow.

Series Casing HP Flanges Speeds Construction Builds
TA Horizontal split 1-450 3-12 in 1160, 1760, 3500 Bronze-fitted 194
HS Horizontal split 3-100 6 in 1160, 1760 Bronze-fitted 42
GT Horizontal split 30-800 12-18 in 1160, 1760 Bronze-fitted, dry shaft 56
TC Vertical split 2-800 5-16 in 1160, 1760 Stainless impeller 195
TS Vertical split 2-800 5-16 in 1160, 1760 Stainless impeller 191
Quick rule: up to 100 HP on 6 in connections, HS is the compact choice. Up to 450 HP with the most speed options, TA. Where floor space is tight, TC or TS. Above 450 HP or on 14 to 18 in mains, TC, TS or GT.

Pressure and temperature ratings are the same for all five: 175 psig standard, 300 psig with 250# flanges, liquid to 250°F.

Split Case Against End Suction

The closest alternatives on our site are end suction pumps. Below about 200 HP they often do the same job for less money and floor space; above it, split case takes over.

Pump Type HP Published range Speeds Construction
Taco TA Double suction, horizontal split 1-450 Per-build curve 1160, 1760, 3500 RPM Bronze-fitted, 300 psig option
Taco TC / TS Double suction, vertical split 2-800 Per-build curve 1160, 1760 RPM Stainless impeller
Grundfos NBS 1750 End suction, split-coupled 1-200 To 4,596 GPM, 257 ft 1750 RPM Cast iron, liquid to 284°F
Grundfos NBS 3500 End suction, split-coupled 3-125 To 2,030 GPM, 448 ft 3500 RPM Cast iron, liquid to 284°F
Taco FI End suction, base-mounted 1-150 Per-build curve 1160, 1760, 3500 RPM Bronze-fitted, dry shaft

Verdict: under about 200 HP, a Grundfos NBS or Taco FI end suction pump is usually the lower-cost choice with a smaller footprint, and NBS reaches the highest head here (448 ft at 3500 RPM) and the hotter liquid (284°F). Choose split case when the duty is above 200 HP, when the available NPSH is low, when the pump runs around the clock and bearing life matters most, or when one pump must carry flows beyond what an end suction pump publishes.

Selection Guide by Application

Start from the loop and the hours it runs. The series named is where we would start; the curve decides the build.

Application Duty Start with Notes
Primary chilled water, one pump per chiller Constant flow, 24/7 TA, TC 1160 or 1760 RPM for quiet running and long seal life
Condenser water to cooling towers Constant flow, high flow TA, GT Check NPSH available at the tower basin level
District and campus distribution Large flow, variable GT, TC Run on a SmartDrive for variable flow
Plant room with little floor space Constant or variable TC, TS Top suction and discharge shorten the piping run
Mid-size heating or cooling loop Up to 100 HP HS 6 in connections; compare against an end suction pump
Pressure boosting and water supply High flow TA at 3500 RPM Bronze-fitted; confirm suction pressure

Sizing and Best Practices

Two numbers pick the pump: the flow the load needs and the head the loop takes at that flow. A third, NPSH, decides whether it will run quietly.

Flow from load. For water, GPM = BTU/h ÷ (500 × ΔT), where ΔT is the supply-to-return difference in °F. A ton of cooling is 12,000 BTU/h. Glycol carries less heat per gallon, so it needs more flow for the same load.

Worked example: a 1,200-ton primary loop at a 10°F ΔT. 1,200 × 12,000 = 14,400,000 BTU/h. 14,400,000 ÷ (500 × 10) = 2,880 GPM. Split across three chillers with one pump each, that is 960 GPM per pump. Add the friction of the chiller, piping and fittings at that flow for the head, or run the HVAC Pump Calculator.

NPSH. The net positive suction head available at the pump must exceed the NPSH required on the curve, with margin. Condenser pumps drawing from a tower basin are the usual problem; the double suction impeller's low NPSH required is a main reason split case pumps are chosen there.

Speed. At the same duty, a 1160 or 1760 RPM build is larger and costs more than a 3500 RPM build but runs quieter with longer seal and bearing life. Most 24/7 HVAC plants choose 1760 or 1160 RPM.

Before you order: confirm the liquid and glycol percentage, the system working pressure (above 175 psig needs the 250# flange option), the supply voltage, and whether the pump runs on a drive.

What Sets These Pumps Apart

Common to the Taco split case range, from each listing.

Double Suction Impeller

Water enters both sides of the impeller, so axial thrust all but cancels and bearings carry less load.

Service Without Re-Piping

The casing splits along the shaft (horizontal) or opens with cast feet left in place (vertical), so the piping stays connected.

Low NPSH Required

The TA impeller is designed for low NPSH required and stable performance across its range.

Dry Shaft on GT

The GT keeps the pumped fluid off the shaft, protecting it from corrosion.

Bronze or Stainless

Bronze-fitted TA, HS and GT; stainless steel impellers on TC and TS.

Trimmed to Your Duty

Taco trims the impeller to the duty point on your order, so the pump does not run far out on its curve.

Why Order from Watermain Supply

Engineering-Led Selection

We read your duty point on the published curve and check voltage, liquid and site conditions before the order is placed.

Honest Across Brands

We supply Taco, Grundfos, Franklin Electric, DAB and A.Y. McDonald. If one is not the right fit for the duty, we will say so and show you what is.

The Right US Build

Every listing is a 60 Hz US build with the part number the manufacturer orders against, so what arrives matches the submittal.

One Order for the Plant Room

Pumps, drives, valves, sensors and tanks on one quote and one purchase order.

Account Terms

Contractors, engineers and facility teams can buy on account. Ask for a credit application with your first quote.

Houston and Gulf Coast Service

Based in Houston and serving the Gulf Coast and the US, with parts and aftermarket support after start-up.

Frequently Asked Questions

What is a split case pump?

A pump whose casing is split along the shaft so the rotating assembly can be removed for service. Most, including all five Taco series here, use a double suction impeller that takes water in from both sides.

Horizontal or vertical split case?

Horizontal split case (TA, HS, GT) opens from the top and suits most plant rooms. Vertical split case (TC, TS) has top suction and discharge connections and a smaller footprint where floor space is tight.

When is split case better than end suction?

Above about 200 HP, at low NPSH available, for 24/7 primary duty where bearing life matters most, or for flows beyond what an end suction pump publishes. Below that, end suction is usually cheaper and smaller.

What pressure and temperature are they rated for?

175 psig standard and 300 psig with 250# flanges, with liquid to 250°F, for all five series.

Can a split case pump run on a VFD?

Yes. Pair it with a Taco SmartDrive sized to the motor, with a bypass panel if the pump must keep running when the drive is out of service.

Which speed should I choose?

1160 or 1760 RPM for quiet, long-life 24/7 HVAC duty; 3500 RPM (TA only) for a smaller, lower-cost pump where noise and seal life matter less.

What warranty comes with Taco split case pumps?

Taco's published terms for commercial pumps. Ask us for the terms document with your quote.

How do I order and what is the lead time?

Order online by build or request a quote. Split case pumps are built to order with the impeller trimmed to your duty; lead time is confirmed with your quote.

Ready to Size Your Split Case Pump?

Send the flow, head, liquid and voltage. We match the build on the Taco curve and quote the pump, drive and valves together.

Technical data on this page is taken from manufacturer literature as published on our listings and is subject to change by the manufacturer. Confirm against the current submittal and installation manual before specifying. Taco is a trademark of Taco, Inc.; Grundfos and NBS are trademarks of Grundfos Holding A/S. Names are used here for product identification only. Watermain Supply is a DBA of E4 Industrial LLC, an independent industrial supplier based in Houston, Texas.