Taco HS Horizontal Split Case Pump - Double Suction, Bronze-Fitted

HP - Speed: 3 HP - 1160 RPM
Suction x Discharge: 6 x 5 in
Model: HS060509

Product variant with selected options does not exist!

Price
$13,383.12
Coupon 5% off applied automatically in your cart. No code needed.
SKU: HS060509-1160-3HP
Weight : 780.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Taco · Double Suction Split Case Pump, Horizontal
HS Series
42 US builds: 4 pump sizes, 3-100 HP, 6 in flanges, 1160 to 1760 RPM, 60 Hz.
3-100 HP Horizontal
1160 or 1760 RPM, 60 Hz
6 in Flanges
175 psig Std, 300 psig with 250# Flanges
250°F Max Liquid
Bronze-Fitted
725-1952 lb Weight
Overview

The HS is Taco’s single-stage, double suction horizontal split case pump for heating, air conditioning, pressure boosting, cooling water transfer and water supply. A short, rigid shaft keeps deflection low at every operating point, which cuts seal wear, bearing load and vibration, and the mechanical seal and bearings can be reached without lifting the top casing. The top half still comes off to service the rotating unit without disturbing the piping. Each build on this listing is one pump size at one speed with one motor HP; Taco trims the impeller to your duty point when the pump is ordered.

  • High-efficiency double suction bronze impeller, hydraulically and dynamically balanced
  • Replaceable case wear rings separate from the casing
  • Fully welded, reinforced structural steel base with drip pan
  • Cast iron casing for 125# flanges; ductile iron casing and cover for 250# flanges
What Ships and What It Needs to Run

Included: the HS pump and its NEMA T-frame motor, mounted and aligned on a common welded steel base with drip pan, flexible coupler and coupler guard.

Set when you order: the impeller diameter for your duty point, motor voltage and enclosure (ODP or TEFC), and the rotation, clockwise or counterclockwise viewed from the motor end.

Foundation and grout: a concrete pad, anchor bolts and grout, provided on site.

Ships by freight: about 725-1952 lb by build; plan for a lift at delivery.

Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty

Covered for 1 year from start-up or 18 months from shipment, whichever comes first, under Taco’s limited warranty for commercial pumps. Taco states that the motor is warranted by the motor manufacturer and that seals are not covered.

Specifications
Pump type Single-stage double suction horizontal split case pump, base-mounted
Motor NEMA standard T-frame motor, ODP or TEFC
Speed 1160 or 1760 RPM by build, 60 Hz
Connections ANSI Class 125 flanges (standard) or Class 250, 6 in
Maximum working pressure 175 psig with Class 125 flanges; 300 psig with Class 250 flanges
Maximum liquid temperature 250°F
Mechanical seal Mechanical seal, Ni-Resist seat and carbon rotor with EPT elastomers, rated to 250°F

From the Taco submittal data sheets, catalog and IOM.

Models & Performance — Will It Do What You Need?

Each block is one flange size at one speed. Every row is one pump size this listing sells, with the motor HP range Taco offers for it, and every figure is the total head in feet the pump adds at the flow heading the column, on the largest impeller Taco offers for that size. Taco trims the impeller to the duty point you order, which brings the curve down to it; the full family of impeller curves for each size is in the image gallery.

HS 6 x 5 in, 1160 RPM: 060509, 060511, 060512, 060515, 3-30 HP, 44-108 ft shut-off, 1,397 GPM
Model, motor 0 GPM 700 1,050 1,397 (Max)
060509, 3-7 1/2 HP 44 31 — —
060511, 3-15 HP 65 48 — —
060512, 7 1/2-20 HP 72 61 51 33
060515, 7 1/2-30 HP 108 88 — —
HS 6 x 5 in, 1760 RPM: 060509, 060511, 060512, 060515, 10-100 HP, 101-249 ft shut-off, 1,996 GPM
Model, motor 0 GPM 1,000 1,500 1,996 (Max)
060509, 10-25 HP 101 76 — —
060511, 15-50 HP 151 116 — —
060512, 20-75 HP 166 144 122 90
060515, 25-100 HP 249 210 — —

Head in feet at the flow in GPM heading each column: 50% and 75% of the largest curve in the block, then its end. Bold = the last column that curve reaches; — = beyond its curve. Maximum-impeller curves digitized from the Taco HS 60 Hz performance curves and rounded down. PSI = feet ÷ 2.31.

Before You Buy — The Limits That Decide the Fit
Duty point Pick the size whose curve passes through your flow and head; send it to us and we will confirm the impeller trim with Taco before you order
Liquid Water or other suitable HVAC media; not for hazardous, corrosive or flammable liquids
Mounting On a grouted concrete foundation; Taco notes that the Hydraulic Institute and ASHRAE always recommend grouting the base
Priming Fill and vent the pump before starting; never run it dry
Pressure 175 psig with Class 125 flanges; order Class 250 flanges for up to 300 psig
Installation Notes
  • Install the pump as near the liquid source as possible, with the shortest and most direct suction pipe practical, and leave headroom for a hoist to lift the unit
  • Pour the foundation without interruption, set the anchor bolts in the concrete, shim the base about 1 in above the pad, then grout the base completely and let the grout dry (about 24 hours) before connecting the piping
  • Check pump-to-motor coupling alignment before grouting, after the piping is connected and the system is filled, and after any service; the flexible coupling does not make up for misalignment
  • Support the suction and discharge piping independently so it lines up with the pump flanges without strain; use eccentric reducers on the suction and straight taper reducers on the discharge
  • Vent the casing and never run the pump dry; jog the motor to check rotation, and do not run for long periods against a closed discharge valve

From the Taco HS Base Mounted Pumps IOM 302-376.

Applications

Heating, air conditioning, pressure boosting, cooling water transfer and water supply.

Materials of Construction
Part Bronze-fitted (standard)
Casing and cover Cast iron ASTM A48 Class 30A (125# flanges); ductile iron ASTM A536 65-45-12 (250# flanges)
Impeller Bronze ASTM B584 C83600, C84400 or C87500
Wear ring Bronze ASTM B584 C93200
Shaft sleeve Bronze ASTM B584 C93200
Shaft Carbon steel AISI 1045 (stainless steel Type 416 or 410 optional)

Options: seal flushing line with filter or abrasive separators, stainless steel shaft. From the Taco HS submittal data sheets.

For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

You May Also Like