Taco TC Vertical Split Case Pump - Double Suction, Stainless Impeller

HP - Speed: 2 HP - 1160 RPM
Suction x Discharge: 5 x 3 in
Model: TC050308

Product variant with selected options does not exist!

Price
$12,997.75
Coupon 5% off applied automatically in your cart. No code needed.
SKU: TC050308-1160-2HP
Weight : 948.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Taco · Double Suction Split Case Pump, Vertical Split
TC Series
195 US builds: 22 pump sizes, 2-800 HP, 5 to 16 in flanges, 1160 to 1760 RPM, 60 Hz.
2-800 HP Vertical Split
1160 or 1760 RPM, 60 Hz
5 to 16 in Flanges
175 psig Std, 300 psig with 250# Flanges
250°F Max Liquid
Stainless Steel Impeller
948-7347 lb Weight
Overview

The TC is Taco’s single-stage, double suction vertically split case pump, base-mounted with the motor, for heating, air conditioning, pressure boosting, cooling water transfer and water supply. The casing has top suction and discharge connections to keep the footprint small, integrally cast feet so the pump can be serviced without disturbing the piping, and a dry shaft design that keeps the pumped fluid off the shaft. Each build on this listing is one pump size at one speed with one motor HP; Taco trims the impeller to your duty point when the pump is ordered.

  • Double suction impeller dynamically balanced to ANSI Grade G6.3 and keyed to the shaft
  • Replaceable wear ring and replaceable shaft sleeve
  • Structural steel base with integral drip pan and 3/4 in drain
  • Flexible coupler rated for across-the-line starting and variable frequency drive duty
What Ships and What It Needs to Run

Included: the TC pump and its motor, mounted and aligned on a common structural steel base with drip pan, flexible coupler and coupler guard.

Set when you order: the impeller diameter for your duty point, motor voltage and enclosure (ODP or TEFC), and the rotation, clockwise or counterclockwise viewed from the motor end.

Foundation and grout: a concrete pad, anchor bolts and grout, provided on site.

Ships by freight: about 948-7347 lb by build; plan for a lift at delivery.

Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty

Covered for 1 year from start-up or 18 months from shipment, whichever comes first, under Taco’s limited warranty for commercial pumps. Taco states that the motor is warranted by the motor manufacturer and that seals are not covered.

Specifications
Pump type Single-stage double suction vertically split case pump, base-mounted
Motor NEMA standard T-frame motor, ODP or TEFC; larger builds use 5000-series frames
Speed 1160 or 1760 RPM by build, 60 Hz
Connections ANSI Class 125 flanges (standard) or Class 250, 5 to 16 in
Maximum working pressure 175 psig with Class 125 flanges; 300 psig with Class 250 flanges
Maximum liquid temperature 250°F
Mechanical seal Carbon / silicon carbide mechanical seal, Viton elastomers

From the Taco submittal data sheets, catalog and IOM.

Models & Performance — Will It Do What You Need?

Each block is one flange size at one speed. Every row is one pump size this listing sells, with the motor HP range Taco offers for it, and every figure is the total head in feet the pump adds at the flow heading the column, on the largest impeller Taco offers for that size. Taco trims the impeller to the duty point you order, which brings the curve down to it; the full family of impeller curves for each size is in the image gallery.

TC 5 x 3 in, 1160 RPM: 050308, 050310, 050314, 2-15 HP, 28-90 ft shut-off, 533 GPM
Model, motor 0 GPM 265 400 533 (Max)
050308, 2-3 HP 28 24 — —
050310, 3-7 1/2 HP 45 43 36 —
050314, 7 1/2-15 HP 90 88 82 66
TC 5 x 3 in, 1760 RPM: 050308, 050310, 050314, 7 1/2-50 HP, 66-207 ft shut-off, 809 GPM
Model, motor 0 GPM 405 610 809 (Max)
050308, 7 1/2-10 HP 66 57 — —
050310, 10-20 HP 105 99 83 —
050314, 25-50 HP 207 202 188 153
TC 6 x 4 in, 1160 RPM: 060410, 060412, 5-25 HP, 51-72 ft shut-off, 921 GPM
Model, motor 0 GPM 460 690 921 (Max)
060410, 7 1/2-15 HP 51 50 45 36
060412, 5-20 HP 72 68 59 —
TC 6 x 4 in, 1760 RPM: 060410, 060412, 060416, 10-100 HP, 119-250 ft shut-off, 1,398 GPM
Model, motor 0 GPM 700 1,050 1,398 (Max)
060410, 10-50 HP 119 115 104 84
060412, 30-60 HP 167 157 136 —
060416, 40-100 HP 250 232 175 —
TC 8 x 5 in, 1160 RPM: 080510, 080512, 080515, 080520, 5-75 HP, 42-169 ft shut-off, 1,555 GPM
Model, motor 0 GPM 780 1,170 1,555 (Max)
080510, 5-10 HP 42 33 23 —
080512, 10-20 HP 65 54 43 —
080515, 20-50 HP 113 108 98 81
080520, 40-75 HP 169 163 136 —
TC 8 x 5 in, 1760 RPM: 080510, 080512, 080515, 080520, 15-250 HP, 98-389 ft shut-off, 2,360 GPM
Model, motor 0 GPM 1,180 1,770 2,360 (Max)
080510, 15-40 HP 98 76 53 —
080512, 30-75 HP 149 126 100 —
080515, 75-150 HP 261 249 226 188
080520, 125-250 HP 389 375 315 —
TC 8 x 6 in, 1160 RPM: 080612, 080614, 080618, 080622, 15-200 HP, 56-240 ft shut-off, 2,305 GPM
Model, motor 0 GPM 1,150 1,730 2,305 (Max)
080612, 15-25 HP 56 50 41 —
080614, 20-50 HP 91 86 71 —
080618, 40-100 HP 155 149 136 —
080622, 75-200 HP 240 237 226 193
TC 8 x 6 in, 1760 RPM: 080612, 080614, 080618, 080622, 40-600 HP, 130-551 ft shut-off, 3,495 GPM
Model, motor 0 GPM 1,750 2,600 3,495 (Max)
080612, 40-100 HP 130 116 95 —
080614, 60-200 HP 209 198 166 —
080618, 125-300 HP 357 343 316 —
080622, 300-600 HP 551 545 523 446
TC 10 x 8 in, 1160 RPM: 100813, 100816, 100821, 25-200 HP, 71-226 ft shut-off, 3,488 GPM
Model, motor 0 GPM 1,740 2,600 3,488 (Max)
100813, 25-60 HP 71 66 55 —
100816, 40-100 HP 133 125 106 —
100821, 75-200 HP 226 218 204 179
TC 10 x 8 in, 1760 RPM: 100813, 100816, 100821, 100-800 HP, 163-520 ft shut-off, 5,296 GPM
Model, motor 0 GPM 2,650 3,950 5,296 (Max)
100813, 100-200 HP 163 153 128 —
100816, 125-300 HP 306 287 246 —
100821, 300-800 HP 520 502 469 412
TC 12 x 10 in, 1160 RPM: 121014, 121018, 60-200 HP, 98-162 ft shut-off, 4,805 GPM
Model, motor 0 GPM 2,400 3,600 4,805 (Max)
121014, 60-100 HP 98 90 77 —
121018, 100-200 HP 162 154 134 106
TC 12 x 10 in, 1760 RPM: 121014, 121018, 200-600 HP, 226-372 ft shut-off, 7,397 GPM
Model, motor 0 GPM 3,700 5,550 7,397 (Max)
121014, 200-350 HP 226 208 176 —
121018, 300-600 HP 372 353 306 239
TC 14 x 12 in, 1160 RPM: 141213, 40-75 HP, 60 ft shut-off, 4,674 GPM
Model, motor 0 GPM 2,350 3,500 4,674 (Max)
141213, 40-75 HP 60 55 50 33
TC 14 x 12 in, 1760 RPM: 141213, 125-250 HP, 140 ft shut-off, 7,092 GPM
Model, motor 0 GPM 3,550 5,300 7,092 (Max)
141213, 125-250 HP 140 127 116 76
TC 16 x 12 in, 1160 RPM: 161217, 100-250 HP, 145 ft shut-off, 7,242 GPM
Model, motor 0 GPM 3,600 5,450 7,242 (Max)
161217, 100-250 HP 145 133 118 80
TC 16 x 12 in, 1760 RPM: 161217, 350-800 HP, 334 ft shut-off, 10,996 GPM
Model, motor 0 GPM 5,500 8,250 10,996 (Max)
161217, 350-800 HP 334 306 273 186
TC 16 x 14 in, 1160 RPM: 161415, 60-125 HP, 96 ft shut-off, 7,242 GPM
Model, motor 0 GPM 3,600 5,450 7,242 (Max)
161415, 60-125 HP 96 84 70 31
TC 16 x 14 in, 1760 RPM: 161415, 250-450 HP, 219 ft shut-off, 10,996 GPM
Model, motor 0 GPM 5,500 8,250 10,996 (Max)
161415, 250-450 HP 219 194 163 71

Head in feet at the flow in GPM heading each column: 50% and 75% of the largest curve in the block, then its end. Bold = the last column that curve reaches; — = beyond its curve. Maximum-impeller curves digitized from the Taco TC 60 Hz performance curves and rounded down. PSI = feet ÷ 2.31.

For 060416 at 1160 RPM, Taco publishes no 60 Hz curve we could read: email your duty point and we will confirm the selection with Taco.

Before You Buy — The Limits That Decide the Fit
Duty point Pick the size whose curve passes through your flow and head; send it to us and we will confirm the impeller trim with Taco before you order
Liquid Water or other suitable HVAC media; not for hazardous, corrosive or flammable liquids
Mounting On a grouted concrete foundation, base level, with the piping supported independently of the pump
Priming Fill and vent the pump before starting; never run it dry
Pressure 175 psig with Class 125 flanges; order Class 250 flanges for up to 300 psig
Installation Notes
  • Install the pump as near the liquid source as possible, with the shortest and most direct suction pipe practical, and leave headroom for a hoist to lift the unit
  • Pour the foundation without interruption, set the anchor bolts in the concrete, shim the base about 1 in above the pad, then grout the base completely and let the grout dry (about 24 hours) before connecting the piping
  • Check pump-to-motor coupling alignment before grouting, after the piping is connected and the system is filled, and after any service; the flexible coupling does not make up for misalignment
  • Support the suction and discharge piping independently so it lines up with the pump flanges without strain; use eccentric reducers on the suction and straight taper reducers on the discharge
  • Vent the casing and never run the pump dry; jog the motor to check rotation, and do not run for long periods against a closed discharge valve

From the Taco TC and TS Series Pumps Instruction and Operating Manual 302-055.

Applications

Heating, air conditioning, pressure boosting, cooling water transfer and water supply.

Materials of Construction
Part Standard
Casing Cast iron ASTM A48 Class 30A
Impeller Stainless steel AISI 304
Wear ring Stainless steel AISI 420
Shaft Carbon steel AISI 1045 (stainless steel AISI 420 optional)
Shaft sleeve Stainless steel AISI 420
Mechanical seal Carbon / silicon carbide, Viton
Seal flush line Copper (optional)

Per the current Taco TC submittal data sheets (2024); older Taco catalogs list a bronze impeller as standard, so confirm the fitting with us when you order. From the Taco TC submittal data sheets.

For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

You May Also Like