Taco · Double Suction Split Case Pump, Horizontal
TA Series
194 US builds: 18 pump sizes, 1-450 HP, 3 to 12 in flanges, 1160 to 3500 RPM, 60 Hz.
1-450 HP Horizontal
1160, 1760 or 3500 RPM, 60 Hz
3 to 12 in Flanges
175 psig Std, 300 psig with 250# Flanges
250°F Max Liquid
Bronze-Fitted
509-7215 lb Weight
Overview
The TA is Taco’s single-stage, double suction horizontal split case pump for water circulation. The balanced double-entry impeller all but cancels axial thrust, so the heavy-duty grease-lubricated bearings carry less load, and the impeller is designed for low NPSH required and stable performance across its range. The top half of the casing lifts off to service the rotating assembly without disturbing the piping. Each build on this listing is one pump size at one speed with one motor HP; Taco trims the impeller to your duty point when the pump is ordered.
- Rated to 300 psi working pressure with Class 250 flanges
- Replaceable case wear rings, so the casing does not need replacing when the rings wear
- Flanges and casing tapped and plugged for gauges and priming; air release valve and flushing connections in the upper casing
- Drip type base; two rotation options; packed stuffing box or balanced mechanical seals available
What Ships and What It Needs to Run
Included: the TA pump and its NEMA T-frame motor, mounted and aligned on a common drip type steel base, with flexible coupling and coupling guard.
Set when you order: the impeller diameter for your duty point, motor voltage and enclosure (ODP or TEFC), and the rotation, clockwise or counterclockwise viewed from the motor end.
Foundation and grout: a concrete pad, anchor bolts and grout, provided on site.
Ships by freight: about 509-7215 lb by build; plan for a lift at delivery.
Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty
Covered for 1 year from start-up or 18 months from shipment, whichever comes first, under Taco’s limited warranty for commercial pumps. Taco states that the motor is warranted by the motor manufacturer and that seals are not covered.
Specifications
| Pump type |
Single-stage double suction horizontal split case pump, base-mounted |
| Motor |
NEMA standard T-frame motor, ODP or TEFC |
| Speed |
1160, 1760 or 3500 RPM by build, 60 Hz |
| Connections |
ANSI Class 125 flanges (standard) or Class 250, 3 to 12 in |
| Maximum working pressure |
175 psig with Class 125 flanges; 300 psig with Class 250 flanges |
| Maximum liquid temperature |
250°F |
| Mechanical seal |
Mechanical seal; packed stuffing box and balanced mechanical seals optional |
From the Taco submittal data sheets, catalog and IOM.
Models & Performance — Will It Do What You Need?
Each block is one flange size at one speed. Every row is one pump size this listing sells, with the motor HP range Taco offers for it, and every figure is the total head in feet the pump adds at the flow heading the column, on the largest impeller Taco offers for that size. Taco trims the impeller to the duty point you order, which brings the curve down to it; the full family of impeller curves for each size is in the image gallery.
TA 3 x 2 in, 1160 RPM: 0538, 3-10 HP, 102 ft shut-off, 254 GPM
| Model, motor |
0 GPM |
125 |
190 |
254 (Max) |
| 0538, 3-10 HP |
102 |
96 |
89 |
79 |
TA 3 x 2 in, 1760 RPM: 0538, 7 1/2-30 HP, 233 ft shut-off, 458 GPM
| Model, motor |
0 GPM |
230 |
345 |
458 (Max) |
| 0538, 7 1/2-30 HP |
233 |
218 |
195 |
160 |
TA 3 x 2-1/2 in, 1160 RPM: 0624, 1-3 HP, 40 ft shut-off, 218 GPM
| Model, motor |
0 GPM |
110 |
165 |
218 (Max) |
| 0624, 1-3 HP |
40 |
39 |
36 |
31 |
TA 3 x 2-1/2 in, 1760 RPM: 0624, 3-10 HP, 93 ft shut-off, 333 GPM
| Model, motor |
0 GPM |
165 |
250 |
333 (Max) |
| 0624, 3-10 HP |
93 |
91 |
84 |
72 |
TA 3 x 2-1/2 in, 3500 RPM: 0624, 20-75 HP, 372 ft shut-off, 655 GPM
| Model, motor |
0 GPM |
330 |
490 |
655 (Max) |
| 0624, 20-75 HP |
372 |
364 |
340 |
295 |
TA 4 x 3 in, 1160 RPM: 0824, 0830, 0838, 1 1/2-15 HP, 39-109 ft shut-off, 444 GPM
| Model, motor |
0 GPM |
220 |
335 |
444 (Max) |
| 0824, 1 1/2-5 HP |
39 |
35 |
28 |
— |
| 0830, 2-5 HP |
63 |
53 |
— |
— |
| 0838, 3-15 HP |
109 |
102 |
92 |
78 |
TA 4 x 3 in, 1760 RPM: 0830, 0838, 5-50 HP, 149-255 ft shut-off, 775 GPM
| Model, motor |
0 GPM |
390 |
580 |
775 (Max) |
| 0830, 5-20 HP |
149 |
111 |
— |
— |
| 0838, 10-50 HP |
255 |
230 |
197 |
152 |
TA 4 x 3 in, 3500 RPM: 0824, 30-100 HP, 366 ft shut-off, 1,118 GPM
| Model, motor |
0 GPM |
560 |
840 |
1,118 (Max) |
| 0824, 30-100 HP |
366 |
341 |
297 |
232 |
TA 5 x 4 in, 1160 RPM: 1030, 1038, 3-20 HP, 67-98 ft shut-off, 800 GPM
| Model, motor |
0 GPM |
400 |
600 |
800 (Max) |
| 1030, 3-10 HP |
67 |
57 |
— |
— |
| 1038, 7 1/2-20 HP |
98 |
86 |
71 |
47 |
TA 5 x 4 in, 1760 RPM: 1030, 1038, 10-75 HP, 157-226 ft shut-off, 1,160 GPM
| Model, motor |
0 GPM |
580 |
870 |
1,160 (Max) |
| 1030, 10-40 HP |
157 |
134 |
84 |
— |
| 1038, 25-75 HP |
226 |
201 |
171 |
123 |
TA 6 x 4 in, 1160 RPM: 1024, 2-7 1/2 HP, 40 ft shut-off, 695 GPM
| Model, motor |
0 GPM |
350 |
520 |
695 (Max) |
| 1024, 2-7 1/2 HP |
40 |
38 |
32 |
23 |
TA 6 x 4 in, 1760 RPM: 1024, 7 1/2-20 HP, 92 ft shut-off, 1,079 GPM
| Model, motor |
0 GPM |
540 |
810 |
1,079 (Max) |
| 1024, 7 1/2-20 HP |
92 |
87 |
73 |
52 |
TA 8 x 6 in, 1160 RPM: 1524, 1530, 1538, 1548, 7 1/2-100 HP, 44-164 ft shut-off, 2,112 GPM
| Model, motor |
0 GPM |
1,060 |
1,580 |
2,112 (Max) |
| 1524, 7 1/2-15 HP |
44 |
34 |
— |
— |
| 1530, 7 1/2-25 HP |
72 |
58 |
42 |
— |
| 1538, 15-40 HP |
101 |
92 |
77 |
— |
| 1548, 25-100 HP |
164 |
155 |
140 |
99 |
TA 8 x 6 in, 1760 RPM: 1524, 1530, 1538, 1548, 25-300 HP, 100-376 ft shut-off, 3,221 GPM
| Model, motor |
0 GPM |
1,610 |
2,400 |
3,221 (Max) |
| 1524, 25-40 HP |
100 |
79 |
— |
— |
| 1530, 25-75 HP |
168 |
136 |
— |
— |
| 1538, 50-150 HP |
232 |
213 |
177 |
— |
| 1548, 100-300 HP |
376 |
358 |
323 |
225 |
TA 10 x 8 in, 1160 RPM: 2030, 2038, 2048, 10-125 HP, 83-166 ft shut-off, 2,870 GPM
| Model, motor |
0 GPM |
1,440 |
2,150 |
2,870 (Max) |
| 2030, 10-40 HP |
83 |
72 |
— |
— |
| 2038, 25-50 HP |
100 |
90 |
74 |
— |
| 2048, 50-125 HP |
166 |
160 |
150 |
134 |
TA 10 x 8 in, 1760 RPM: 2030, 2038, 2048, 40-450 HP, 191-382 ft shut-off, 4,467 GPM
| Model, motor |
0 GPM |
2,250 |
3,350 |
4,467 (Max) |
| 2030, 40-125 HP |
191 |
166 |
— |
— |
| 2038, 100-200 HP |
230 |
210 |
172 |
— |
| 2048, 150-450 HP |
382 |
369 |
344 |
302 |
TA 10 x 10 in, 1160 RPM: 2524, 2530, 10-50 HP, 46-74 ft shut-off, 3,396 GPM
| Model, motor |
0 GPM |
1,700 |
2,550 |
3,396 (Max) |
| 2524, 10-20 HP |
46 |
36 |
— |
— |
| 2530, 15-50 HP |
74 |
65 |
53 |
29 |
TA 10 x 10 in, 1760 RPM: 2524, 2530, 40-150 HP, 108-166 ft shut-off, 4,595 GPM
| Model, motor |
0 GPM |
2,300 |
3,450 |
4,595 (Max) |
| 2524, 40-75 HP |
108 |
88 |
63 |
— |
| 2530, 50-150 HP |
166 |
153 |
134 |
99 |
TA 12 x 10 in, 1160 RPM: 2538, 40-100 HP, 115 ft shut-off, 3,778 GPM
| Model, motor |
0 GPM |
1,890 |
2,850 |
3,778 (Max) |
| 2538, 40-100 HP |
115 |
109 |
97 |
76 |
TA 12 x 10 in, 1760 RPM: 2538, 125-300 HP, 269 ft shut-off, 5,802 GPM
| Model, motor |
0 GPM |
2,900 |
4,350 |
5,802 (Max) |
| 2538, 125-300 HP |
269 |
252 |
225 |
169 |
Head in feet at the flow in GPM heading each column: 50% and 75% of the largest curve in the block, then its end. Bold = the last column that curve reaches; — = beyond its curve. Maximum-impeller curves digitized from the Taco TA 60 Hz performance curves and rounded down. PSI = feet ÷ 2.31.
For 0824 at 1760 RPM and 1024 at 3500 RPM, Taco publishes no 60 Hz curve we could read: email your duty point and we will confirm the selection with Taco.
Before You Buy — The Limits That Decide the Fit
| Duty point |
Pick the size whose curve passes through your flow and head; send it to us and we will confirm the impeller trim with Taco before you order |
| Liquid |
Water or other suitable HVAC media; not for hazardous, corrosive or flammable liquids |
| Mounting |
On a grouted concrete foundation, base level, with the piping supported independently of the pump |
| Priming |
Fill and vent the pump before starting; never run it dry |
| Pressure |
175 psig with Class 125 flanges; order Class 250 flanges for up to 300 psig |
Installation Notes
- Install the pump as near the liquid source as possible, with the shortest and most direct suction pipe practical, and leave headroom for a hoist to lift the unit
- Pour the foundation without interruption, set the anchor bolts in the concrete, shim the base about 1 in above the pad, then grout the base completely and let the grout dry (about 24 hours) before connecting the piping
- Check pump-to-motor coupling alignment before grouting, after the piping is connected and the system is filled, and after any service; the flexible coupling does not make up for misalignment
- Support the suction and discharge piping independently so it lines up with the pump flanges without strain; use eccentric reducers on the suction and straight taper reducers on the discharge
- Vent the casing and never run the pump dry; jog the motor to check rotation, and do not run for long periods against a closed discharge valve
From the Taco TA Base Mounted Pumps Instruction and Operating Manual 302-013.
Applications
HVAC heating and cooling water circulation, condenser and chilled water, pressure boosting and water transfer.
Materials of Construction
| Part |
Bronze-fitted (standard) |
| Casing |
Cast iron ASTM A48 Class 30A |
| Impeller |
Bronze ASTM B584-836 |
| Wear ring |
Bronze ASTM B584-836, replaceable |
| Shaft |
Carbon steel AISI 1045 (stainless steel AISI 420 optional) |
| Shaft sleeve |
Bronze ASTM B584-836 (stainless steel AISI 420 optional) |
Options: stainless steel shaft and shaft sleeve AISI 420, seal flush line with filter or abrasive separator. From the Taco TA submittal data sheets.