Franklin Electric 3-wire control boxes for single-phase submersible motors from 1/3 to 15 HP: QD boxes with the solid-state QD relay, CRC boxes with a run capacitor, and Standard and Deluxe boxes with overloads and line contactor. Replacement capacitors, relays, overloads and contactors are listed by Franklin kit number against the box model. Cerus X-Drive VFD pump panels (3 to 600 HP), stand-alone drives to 770 A, line and load reactors and dV/dt filters cover variable-speed submersible and surface pumps. We also supply Grundfos and A.Y. McDonald boxes and drives, so we match the one that fits your motor. Call 1-888.510.4036.
Franklin 3-wire control boxes (QD, CRC, Standard and Deluxe) and replacement capacitors, relays and overloads for single-phase submersible motors, plus Cerus X-Drive VFD pump panels, stand-alone drives, line and load reactors and dV/dt output filters. U.S. 60 Hz builds, matched to your motor nameplate, compared honestly with Grundfos and A.Y. McDonald.
1/3–15 HP3-wire control boxes
53Box repair kits
3–600 HPX-Drive panels
770 ALargest stand-alone drive
Up to 8Drives in multi-VFD control
This collection covers the Franklin Electric equipment between the power supply and the pump motor. Franklin 3-wire control boxes start and protect Franklin single-phase 3-wire submersible motors from 1/3 to 15 HP, and every capacitor, relay, overload and contactor inside them is listed by Franklin kit number. The Cerus X-Drive is Franklin’s variable frequency drive for variable-torque pumping, sold as an outdoor NEMA 3R pump panel for submersible (SUB) or centrifugal (CEN) pumps, or as a stand-alone NEMA 1 drive for panel builders. Reactors and dV/dt filters protect the drive, the supply and the motor windings. It is built for well drillers, pump contractors, municipal and agricultural water systems, panel shops and facility maintenance teams.
We supply U.S. 60 Hz builds at 115V, 230V, 460V and 575V, including configured-to-order X-Drive panels with factory options, and we also supply the Grundfos and A.Y. McDonald equivalents, so we can tell you which one fits your motor. Our engineering-led selection checks the box, drive or filter against your motor nameplate, supply and cable run before you order — call 1-888.510.4036 or email sales@watermainsupply.com. Genuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Will It Work for Me?
Four checks that rule a Franklin control box or drive in or out before you spend time on part numbers.
Warranty
Cerus X-Drive drives and panels carry Franklin’s standard limited warranty for one year from the date of installation, and in no event more than two years from the date of manufacture, per the Cerus X-Drive Installation and Operation Manual. Franklin’s X-Drive brochure (M1789) adds that drives are eligible for an Extended Warranty when paired with a Franklin-supplied motor and pump.
For control boxes, reactors and filters, we confirm the applicable Franklin term with your quote. Full terms and conditions are in the manufacturer’s manual.
Reliability
In QD and CRC boxes the solid-state QD relay outlasts a voltage relay, and every box is built from components Franklin tests as a matched set for its own motors. The X-Drive trips on overvoltage, undervoltage, overcurrent, ground fault, input phase loss and output phase open, and adds pump protections such as underload, broken pipe and no-flow. Short-circuit rating is 100 kA with suitable Class J fuses.
Fit
Control boxes: for Franklin single-phase 3-wire submersible motors, matched to the motor HP and voltage. A 2-wire motor has its starting parts built in and uses no box.
Drives: the X-Drive runs three-phase induction and MagForce permanent-magnet motors; single-phase input works through UL-listed phase conversion at reduced output. At 460V and 575V, leads past 1,000 ft need a sine wave filter.
Match It Now
Send the motor nameplate (make, HP, voltage, phase, 2- or 3-wire, FLA or SFA), your supply and the cable length. We return a matched part number and the manufacturer submittal.
Three groups cover the collection: single-phase 3-wire control boxes and their parts, X-Drive VFD pump panels and drives, and the filtering and accessories around them.
3-Wire Control Boxes & Parts
QD · CRC · Standard · Deluxe
1/3–15 HPMotor HP
115V / 230VSingle-phase
NEMA 3ROutdoor, IP23
UL listed60 Hz models
A Franklin 3-wire single-phase submersible motor has no starting components in the motor, so the control box supplies them: start capacitor, relay, overloads and, on some boxes, a run capacitor or line contactor. QD and CRC boxes cover 1/3 to 1 HP; Standard and Deluxe cover 1 to 15 HP. Replacement parts are listed by Franklin kit number against the box model.
Key specs
QD: solid-state QD relay; lid removal disconnects the control components
CRC: adds a run capacitor for smoother, cooler motor operation
Standard: capacitor start/run with overloads, terminals to AWG 2
Best forResidential and farm wells, livestock water, and replacing a failed box, capacitor or relay on an existing Franklin 3-wire motor.
The same X-Drive in three forms. The SUB panel is set up for 4, 6 and 8 in submersible motors; the CEN panel for centrifugal and other surface pumps. Both are NEMA 3R with a circuit breaker disconnect, a line reactor or DC choke, and a dV/dt output filter at 460V and 575V. The stand-alone drive is NEMA 1 for indoor mounting or building into your own panel.
Key specs
Panels at 200-230V, 460V and 575V; single-phase input panels at 200-230V and 460V
Low-harmonic XSLH and XCLH panels at 460V, designed to IEEE-519
Stand-alone CXD drives from 3 A to 770 A output
Best forConstant-pressure wells, irrigation, municipal boosting and lift stations, VR booster pumps and panel-shop builds.
Line reactors smooth the current a drive draws and cut harmonics on the supply. Load reactors and dV/dt filters slow the voltage rise reaching the motor, which protects winding insulation on long cable runs. X-Drive accessories add pressure feedback, communications and I/O.
Key specs
Reactors: 200/230V, 460V and 575V; NEMA 1 or NEMA 3R; line or load duty
dV/dt filters: 460V and 575V, V1K series, NEMA 1 or NEMA 3R
4-20 mA pressure transducers PSIG-100-20FT, PSIG-200-20FT, PSIG-300-20FT
Best forStand-alone drives, retrofits of existing panels, long submersible leads and MagForce permanent-magnet motors.
Find your box by motor HP and voltage. Every box below is a 60 Hz, single-phase model on our 3-wire control box listing.
Motor HP / volts
QD
CRC (run capacitor)
Standard
Deluxe (contactor)
1/3 HP, 115V
280 102 4915 2801024915
—
—
—
1/3 HP, 230V
280 103 4915 2801034915
—
—
—
1/2 HP, 115V
280 104 4915 2801044915
—
—
—
1/2 HP, 230V
280 105 4915 2801054915
282 405 5015 2824055015
—
—
3/4 HP, 230V
280 107 4915 2801074915
282 407 5015 2824075015
—
—
1 HP, 230V
280 108 4915 2801084915
282 408 5015 2824085015
—
—
1-1/2 HP, 230V
—
—
282 300 8110 2823008110
—
2 HP, 230V
—
—
282 301 8110 2823018110
282 301 8310 2823018310
3 HP, 230V
—
—
282 302 8110 2823028110
282 302 8310 2823028310
5 HP, 230V
—
—
282 113 8110 2821138110
282 113 9310 2821139310
7-1/2 HP, 230V
—
—
282 201 9210 2822019210
282 201 9310 2822019310
10 HP, 230V
—
—
282 202 9230 2822029230
282 202 9330 2822029330
15 HP, 230V
—
—
—
282 203 9330 2822039330
The listing also carries 220V Standard boxes (282 350 8110, 282 351 8110, 282 352 8110, 282 253 9010), which Franklin catalog M1748 lists as 50 Hz models. For U.S. 60 Hz service choose the 230V box. Source: Franklin Motors and Control Boxes Catalog M1748.
3-Wire Control Box vs X-Drive SUB vs CEN vs Stand-Alone
How the four product families in this collection differ, using Franklin literature and the order numbers listed in each product.
Feature
3-wire control box
X-Drive SUB panel
X-Drive CEN panel
Stand-alone X-Drive
Runs
Franklin 1Ph 3-wire submersible motor
3-phase submersible motors, 4, 6 and 8 in, incl. MagForce
Centrifugal and surface pump motors, e.g. VR
Any variable-torque motor within its amp rating
Speed control
Fixed speed, start and protect
Variable
Variable
Variable
Single-phase input
Single-phase only
3–30 HP at 200-230V; 3–75 HP at 460V
3–30 HP at 200-230V; 3–100 HP at 460V
Most ratings, at reduced output
Range listed
1/3–15 HP
3–550 HP
3–600 HP
3–770 A output
Filtering
—
Reactor or DC choke; dV/dt filter at 460/575V
Reactor or DC choke; dV/dt filter at 460/575V
Add reactor or dV/dt filter by lead length
Match on
Motor HP, voltage, 3-wire
Motor HP, voltage, SFA
Motor HP, voltage, FLA
Motor amps and voltage class
Ranges are the base part numbers listed in our product pages from the Franklin price list; Franklin rates the X-Drive family from 1 HP. Sources: Cerus X-Drive brochure M1789, Low Harmonics spec sheet M5055, Motors and Control Boxes Catalog M1748.
Quick rule. Single-phase 3-wire submersible at fixed speed: a Franklin control box matched to the motor HP and voltage. Three-phase motor and you want variable speed: X-Drive — SUB panel for a submersible, CEN panel for a surface pump, stand-alone drive if it goes inside your own enclosure. The one mistake we see most: choosing a drive on horsepower alone when the motor amps are higher than the drive rating.
Franklin vs Grundfos vs A.Y. McDonald (Baker)
We supply all three brands, so here is how they really compare. Figures for Grundfos and A.Y. McDonald come from our own product pages for those lines; price positions are from our current prices.
Single-phase 3-wire control boxes
Feature
Franklin QD, CRC, Standard, Deluxe
Grundfos SA-SPM6
A.Y. McDonald 4 in and 6 in boxes
Built for
Franklin 1Ph 3-wire submersible motors
Grundfos 4 in 1Ph 3-wire submersible motors
1Ph 3-wire submersible motors
HP range
1/3–15 HP
1/2–15 HP
1/2–5 HP (4 in); 7-1/2–15 HP (6 in Deluxe)
Box types
4: QD, CRC, Standard, Deluxe
2: Standard, Deluxe
3: Standard capacitor start, Standard capacitor start and run, Deluxe
Starting relay
Solid-state QD relay (QD, CRC); relay in Standard and Deluxe
Potential relay
Relay; replacement relay kits listed
Motor protection
Overloads in Standard and Deluxe
Motor protective circuit breaker in Standard
Starting and running overloads
Run capacitor at 1 HP and under
Yes, CRC box
Not listed
No; start and run from 1-1/2 HP
Line contactor
Deluxe, 2–15 HP
Deluxe, 1-1/2–15 HP
Deluxe, 1-1/2–15 HP
Voltage
115V (1/3–1/2 HP) and 230V
115V (1/2 HP) and 230V
115V (1/2 HP) and 230V
Enclosure
NEMA 3R, IP23; UL listed US and Canada
IP42 / NEMA 3R; -4 to 140 °F ambient
See product page
Buy one at a time
Every size
1/2–1 HP in 10-packs only; single boxes from 1-1/2 HP
Honest verdict. The motor decides first: each maker builds its box around the starting components its own 3-wire motor needs, so buy the box that matches the brand on the motor nameplate, or send us the nameplate and we will confirm a match. After that: Franklin wins on choice and on single small boxes — it is the only one of the three with a 1/3 HP box, a run-capacitor box (CRC) at 1 HP and under, and the solid-state QD relay. Grundfos wins on price from 1-1/2 HP up, and its Standard box uses a motor protective circuit breaker, but its 1/2 to 1 HP boxes come only in packs of ten, which suits a contractor stocking a truck better than a homeowner. A.Y. McDonald covers 1/2 to 15 HP at prices close to Franklin and sells every capacitor, relay, overload and contactor as a separate part.
Variable-speed drives for pumps
Feature
Franklin Cerus X-Drive
Grundfos CUE
Grundfos CUE 100
A.Y. McDonald AutoDRIVE
What it is
VFD for variable-torque pumping: outdoor SUB or CEN panel, or stand-alone drive
Wall-mounted frequency converter with E-pump functions, engineered for Grundfos pumps
Constant-pressure drive for Grundfos SP 3-phase submersibles
VFD for submersible motors with constant pressure
Range
Panels 3–600 HP; stand-alone 3–770 A
0.75–300 HP; 14.5–443 A (NEMA 1 or 12); IP66 version 1.6–170 A
4 sizes, 6–18.5 A motor SF amps
2–5 HP 3-phase output; 1/2–2 HP single-phase output
Supply
200-240V, 380-480V, 575V; single-phase input at reduced output
200-240V 1Ph (1.5–7.5 HP) or 3Ph; 380-500V 3Ph
200-240V 1Ph in, 3Ph out
Single-phase output 115/230V; 3-phase output 230V
Motors it runs
3-phase induction and MagForce permanent-magnet motors
Grundfos pumps and motors
Grundfos SP 3-phase motors
2-wire and 3-wire single-phase and 230V 3-phase submersibles
Enclosure
Panels NEMA 3R; stand-alone NEMA 1
NEMA 1, NEMA 12 or IP66
NEMA 4X / IP66
See product page
Pressure sensor
100, 200 or 300 psig transducer, accessory
Sold separately
Included
Transducer model or pressure switch model
Control and protection
Underload, broken pipe, pipe fill, no-flow, multi-VFD control of up to 8 drives
Constant pressure, differential pressure, level and temperature; dry-run protection; duty/standby
Constant pressure
Soft start and stop, overload and dry-run protection
Networking
Modbus RTU/ASCII and BACnet MS/TP built in; Modbus TCP/IP and FE Connect Bluetooth cards
Multiple I/O and network options
—
—
Output filtering
Panels include reactor or choke and, at 460/575V, a dV/dt filter; reactors and filters also listed
Honest verdict. For a homeowner well with a Grundfos SP pump on single-phase power, the Grundfos CUE 100 is the simplest buy: transducer included, NEMA 4X outdoor box, four sizes. The A.Y. McDonald AutoDRIVE is the only drive here that gives variable speed to a single-phase 2-wire or 3-wire motor, up to 2 HP, which saves replacing the motor. The Grundfos CUE is the natural choice when the pump is Grundfos and you want its level, temperature and differential-pressure modes. The Franklin X-Drive wins everywhere else: Franklin and other-brand motors, MagForce permanent-magnet motors, sizes to 600 HP, packaged outdoor panels with the disconnect and filtering already inside, Modbus and BACnet without an add-on card, and multi-pump control across up to eight drives.
Control box repair parts and starters
Feature
Franklin control box parts
A.Y. McDonald control box components
Grundfos
What is listed
53 kits in one listing: start and run capacitors, relays, overloads, contactors
Separate listings for start and run capacitors, relays, starting and running overloads, contactors, plus 1/2–1 HP kits
No box parts; MP 204 electronic motor protector for 1Ph and 3Ph motors to 75 HP
How you order
By Franklin kit number against the box model on the label
By motor HP, 230V, 1/2–15 HP
—
3-phase motor starting
X-Drive panels (variable speed)
Starter kits for 3-phase submersibles, 5–75 HP; IEC starter kits 1/2–10 HP
Honest verdict. Repair parts follow the box, not the brand you prefer: order Franklin kits for a Franklin box and A.Y. McDonald parts for an A.Y. McDonald box, and match capacitor microfarad and voltage exactly. For a three-phase submersible started across the line, A.Y. McDonald’s starter kits are the only packaged option on our site; for variable speed, the X-Drive panel replaces the starter.
Selection Guide: Which Control Box or Drive
Start from the job. We confirm the final part number against the manufacturer submittal and your motor nameplate.
Sizing and Matching Franklin Drives and Control Boxes
Controls are matched, not guessed. Every part here is chosen from the motor nameplate, the power supply and the cable run.
3-Wire Control Box: Match Brand, HP, Voltage and Wires
Read the motor nameplate. It must say 3-wire, single-phase. The control box HP and voltage must equal the motor HP and voltage; a box for a larger or smaller motor carries the wrong capacitor and overload values. Use the box brand that matches the motor.
Worked example (control box and part). 1 HP, 230V, 3-wire Franklin submersible on a pressure switch. Franklin offers the QD box 280 108 4915, the CRC box 282 408 5015 (adds a 23 MFD, 370 V run capacitor), or the Standard 282 300 8110 that covers 1 to 1-1/2 HP. If an existing QD box 280 108 4915 fails to start the motor, the M1748 parts table lists start capacitor 105-126 MFD, 220 V (kit 305 207 913) and QD relay (kit 305 101 904) for that box. Match the capacitor MFD and voltage exactly.
X-Drive: Match the Motor, Then the Supply, Then the Cable
1. Motor. X-Drive panels are horsepower-rated: the HP in the part number (XS4BH025-3A = 25 HP) should match the motor nameplate HP, and the voltage code (2 = 200-230V, 4 = 460V, 6 = 575V) the motor voltage. Stand-alone drives are amp-rated: the drive output must be at least the motor FLA, or SFA for a submersible.
2. Supply. The input suffix -3A is three-phase, -1A single-phase. On single-phase input a stand-alone drive delivers reduced output: about half the three-phase rating on smaller frames and about one third on larger frames, as listed per model.
3. Cable. Franklin’s X-Drive Quick Start for 460V and 575V: load reactor from 45 to 100 ft drive-to-motor, dV/dt filter from 100 to 1,000 ft, sine wave filter beyond that. For submersible pumps the guide calls for the dV/dt filter at 800 ft, and catalog M1748 requires an output filter on any permanent-magnet motor (dV/dt to 800 ft, sine wave beyond). Output reactors and filters are not required at 200/230V. Size power wire for less than 2% voltage drop.
Worked example (stand-alone drive). 20 HP, 460V, 6 in submersible. Franklin lists a service factor amp figure of 30.3 A for this motor in the X-Drive Low Harmonics sheet M5055. Three-phase supply: CXD-032A-4V is rated 32 A, and 32 A ≥ 30.3 A, so it covers the motor. Single-phase supply: CXD-032A-4V drops to 16 A and CXD-060A-4V to 30 A, both under 30.3 A; CXD-073A-4V delivers 36.5 A on single-phase and covers it. A 600 ft cable route sits in the 100–1,000 ft band, so add a dV/dt filter rated at least 30.3 A: V1K35A03 (35 A, NEMA 3R) outdoors. The panel alternative is XS4BH020-3A, which already includes the reactor or choke and the dV/dt filter.
Franklin X-Drive and Control Box Ratings
Documented manufacturer figures only. Motor HP is nameplate HP.
3-Wire Control Box Specifications
Box type
Frequency
Motor HP
Terminals
Magnetic contactor
QD
60 Hz
1/3–1
5, to AWG 10
No
CRC
60 Hz
1/2–1
5, to AWG 10
No
Standard
60 Hz
1–10
5, to AWG 2
No
Deluxe
60 Hz
1–15
6, to AWG 2
Yes
Source: Franklin Motors and Control Boxes Catalog M1748. All boxes NEMA 3R, IP23, UL listed for the US and Canada.
Cerus X-Drive range: 1–100 HP at 200-208V, 1–125 HP at 230V (322 A max), 1–600 HP at 480V (770 A max) and 1–700 HP at 575V (675 A max), per Franklin brochure M1789.
In QD and CRC boxes the solid-state QD relay outlasts a voltage relay, and removing the lid disconnects the control components for safer troubleshooting.
Deluxe Line Contactor
Deluxe control boxes carry a magnetic line contactor matched to the motor rating, so a pressure or level switch can pilot the motor with no external contactor.
Application Firmware
Presets for submersible pumps, centrifugal pumps, cooling towers and circulating pumps load the right protections at startup, so commissioning takes minutes rather than a parameter-by-parameter build.
Multi-Pump Control
One X-Drive system coordinates up to 8 drives, with pre-PID pipe fill, a second PID loop, dual demand and pipe leak protection — the functions a booster or lift station actually uses.
Filtering Built In
Every panel has a line reactor or DC choke, and 460V and 575V panels add a dV/dt output filter. XSLH and XCLH panels add a passive harmonic filter designed to IEEE-519.
FE Connect App
With the optional Bluetooth card and firmware 1.2 or later: phone-based setup, commissioning reports, logs and One-to-One live support sessions with Franklin or your own team.
Related Franklin Electric Pumps, Motors and Parts
Drives and control boxes are one part of the system. These pages cover the pumps and motors they run.
Packaged drive panel for VR and other surface pumps.
Every drive, filter, control box and replacement part we supply is genuine Franklin Electric, factory-new, ordered by Franklin part or kit number so the component matches the original.
Why Buy Control Boxes and Drives from Watermain Supply
Engineering-Led Sizing
We check drive amps, input phase, lead length and control box model against your motor nameplate before you order, and send the Franklin submittal.
Three Brands, One Answer
We supply Franklin Electric, Grundfos and A.Y. McDonald control boxes and drives. If Franklin is not the right fit for your motor, we will say so and quote the one that is.
Account Terms Available
Net-30 for qualified contractor, property-management and municipal accounts.
Parts & Aftermarket
Capacitors, relays, overloads, contactors, reactors, filters and X-Drive cards by Franklin kit number, for the equipment you already run.
Correct U.S. 60 Hz Build
We match 115V, 230V, 460V or 575V and single- or three-phase input to your service, and flag 50 Hz models before they ship.
One Order, Whole System
Pump, motor, drive, filter and control box on one order from one supplier based in Houston, serving the Gulf Coast.
Franklin Control Box and X-Drive FAQ
Why does a 3-wire submersible motor need a control box?
A Franklin 3-wire single-phase motor has no starting components inside it. The control box supplies the start capacitor, relay and overload protection, and on CRC boxes a run capacitor. The box must match the motor HP and voltage on the nameplate. A 2-wire motor has its starting parts built in and uses no control box.
QD, CRC, Standard or Deluxe: which control box do I need?
QD boxes cover 1/3 to 1 HP with the solid-state QD relay. CRC boxes cover 1/2 to 1 HP and add a run capacitor for smoother operation. Standard boxes cover 1 to 10 HP at 60 Hz, and Deluxe boxes cover 1 to 15 HP and add a magnetic line contactor so no external contactor is needed.
Can I use a Grundfos or A.Y. McDonald control box on a Franklin motor?
Match the box to the brand on the motor nameplate. Each maker builds its box around the starting capacitor, relay and overload values its own 3-wire motor needs, and Franklin boxes are listed for Franklin motors. If the old box is a different brand from the motor, send us both nameplates and we will confirm the right replacement before you order.
How do I order the right control box replacement part?
Read the model number on the control box label, not the motor, and send it to us. Franklin lists every capacitor, relay, overload and contactor by kit order number against that box model. Match capacitor microfarad and voltage ratings exactly; the same microfarad rating at a different voltage is not a substitute.
What warranty comes with a Franklin X-Drive?
Franklin covers the Cerus X-Drive under its standard limited warranty for one year from the date of installation, and in no event more than two years from the date of manufacture, per the Cerus X-Drive Installation and Operation Manual. Franklin also states that drives paired with a Franklin-supplied motor and pump are eligible for an Extended Warranty. Full terms and conditions are in the manufacturer's manual.
Franklin X-Drive or Grundfos CUE: which drive should I buy?
Choose the Grundfos CUE when the pump is Grundfos, since Grundfos engineers the CUE for its own pumps, and the CUE 100 for a Grundfos SP well on single-phase power with the transducer included. Choose the Franklin X-Drive for Franklin and other-brand motors, MagForce permanent-magnet motors, packaged outdoor panels with the filtering inside, sizes to 600 HP, and Modbus or BACnet without an add-on card. We supply both.
What is the difference between the X-Drive SUB and CEN panels?
Both use the same Cerus X-Drive in a NEMA 3R panel with a disconnect. The SUB panel is set up for 4, 6 and 8 in submersible motors and listed from 3 to 550 HP; the CEN panel is set up for centrifugal and surface pumps and listed from 3 to 600 HP. Choose by where the motor is: down the well or on the pad.
Can an X-Drive panel run a three-phase motor from single-phase power?
Yes. Panels with the -1A suffix take single-phase input through UL-listed phase conversion: 3 to 30 HP at 200-230V, and at 460V up to 75 HP for SUB and 100 HP for CEN panels. A stand-alone drive also runs on single-phase input at a reduced output listed for each model.
When do I need a load reactor or a dV/dt filter?
At 460V and 575V, Franklin calls for a load reactor from 45 to 100 ft between drive and motor, a dV/dt filter from 100 to 1,000 ft, and a sine wave filter beyond 1,000 ft. On MagForce permanent-magnet motors an output filter is required at any length: dV/dt up to 800 ft, sine wave beyond, per catalog M1748. At 200/230V output filtering is not required.
Ready to Match Your Control Box or Drive?
Send the motor nameplate, supply voltage and phase, and cable length. We return the matched part number and submittal, and tell you if a Grundfos or A.Y. McDonald unit fits your motor better.
Technical data on this page is taken from Franklin Electric U.S. 60 Hz product literature and, for other brands, from our product pages; it is subject to change by the manufacturer. Confirm against the current installation manual before specifying. Franklin Electric, Cerus, X-Drive, MagForce, FE Connect and One-to-One are trademarks of Franklin Electric Co., Inc. Grundfos, CUE, SP and MP 204 are trademarks of Grundfos Holding A/S. A.Y. McDonald, Baker and AutoDRIVE are trademarks of A.Y. McDonald Mfg. Co. Modbus, BACnet, Bluetooth and IEEE are trademarks of their respective owners. All are used here for product identification only. Watermain Supply is a DBA of E4 Industrial LLC, an independent industrial supplier based in Houston, Texas.