Franklin Electric Control Boxes and Drives

Franklin Electric control boxes and drives: Cerus X-Drive variable frequency drives, the reactors and dV/dt filters that protect them, and single-phase 3-wire control boxes with their replacement parts. X-Drive SUB panels run submersible motors and CEN panels run centrifugal surface pumps, both in NEMA 3R enclosures from 3 to 600 HP. The stand-alone NEMA 1 drive (3 to 770 A) is for building into your own panel. QD and CRC control boxes start Franklin 3-wire submersible motors from 1/3 to 1 HP, and Standard and Deluxe boxes cover 1 to 15 HP. Panels include a line reactor or DC choke, 460V and 575V panels add a dV/dt output filter, and single-phase input panels are UL-listed for phase conversion. The 60 Hz control boxes are UL listed for the US and Canada. We supply U.S. 60 Hz builds at 115V, 200-230V, 460V and 575V, including configured-to-order panels, reactors, filters, X-Drive cards and control box parts by Franklin kit number. Our engineering-led sizing matches the drive or control box to your motor nameplate, supply and cable run before you order. Call 1-888.510.4036 or email sales@watermainsupply.com for a quote and the Franklin submittal.

8 products
Sort by:
Most relevant
Sort by:
Most relevant
Franklin Electric X-Drive SUB VFD Panel for Submersible Pumps
Franklin Electric Cerus X-Drive SUB VFD pump panel, NEMA 3R with disconnect

Franklin Electric

Free Shipping $499 or more

Franklin Electric X-Drive SUB VFD Panel for Submersible Pumps

Price
From $5,811.23
Franklin Electric X-Drive Stand-Alone VFD
Franklin Electric Cerus X-Drive variable frequency drive, NEMA 1

Franklin Electric

Free Shipping $499 or more

Franklin Electric X-Drive Stand-Alone VFD

Price
From $1,081.05
Franklin Electric X-Drive CEN VFD Panel for Centrifugal Pumps
Franklin Electric Cerus X-Drive CEN VFD pump panel, NEMA 3R with disconnect

Franklin Electric

Free Shipping $499 or more

Franklin Electric X-Drive CEN VFD Panel for Centrifugal Pumps

Price
From $5,330.53
Franklin Electric X-Drive Accessories

Franklin Electric

Free Shipping $499 or more

Franklin Electric X-Drive Accessories

Price
From $48.58
Franklin Electric VFD Line and Load Reactor

Franklin Electric

Free Shipping $499 or more

Franklin Electric VFD Line and Load Reactor

Price
From $539.84
Franklin Electric VFD dV/dt Output Filter

Franklin Electric

Free Shipping $499 or more

Franklin Electric VFD dV/dt Output Filter

Price
From $815.14
Franklin Electric Control Box Replacement Parts

Franklin Electric

Free Shipping $499 or more

Franklin Electric Control Box Replacement Parts

Price
From $32.05
Franklin Electric Single-Phase 3-Wire Control Box

Franklin Electric

Free Shipping $499 or more

Franklin Electric Single-Phase 3-Wire Control Box

Price
From $143.32

Franklin Electric Control Boxes and Drives

Franklin Electric

Franklin Electric Control Boxes and Drives

Cerus X-Drive VFD pump panels and stand-alone drives, the line reactors and dV/dt output filters that protect them, and the single-phase 3-wire control boxes and replacement parts that start Franklin submersible motors. U.S. 60 Hz builds, matched to your motor nameplate.

Franklin Electric Cerus X-Drive SUB VFD pump panel, NEMA 3R with disconnect
3–600 HPX-Drive panels, motor HP
770 ALargest stand-alone drive
1/3–15 HP3-wire control boxes
2–750 AdV/dt output filters
Up to 8Drives in multi-VFD control

This collection covers the Franklin Electric equipment that sits between the power supply and the pump motor. The Cerus X-Drive is Franklin’s variable frequency drive for variable-torque pumping, sold as an outdoor NEMA 3R pump panel for submersible (SUB) or centrifugal (CEN) pumps, or as a stand-alone NEMA 1 drive for panel builders. Reactors and dV/dt filters protect the drive, the supply and the motor windings. Franklin 3-wire control boxes (QD, CRC, Standard and Deluxe) start and protect single-phase 3-wire submersible motors from 1/3 to 15 HP. It is built for well drillers, pump contractors, municipal and agricultural water systems, panel shops and facility maintenance teams.

We supply U.S. 60 Hz builds at 115V, 200-230V, 460V and 575V, including configured-to-order X-Drive panels with factory options. Our engineering-led sizing and selection checks the drive, filter or control box against your motor nameplate, supply and cable run before you order — call 1-888.510.4036 or email sales@watermainsupply.com. Genuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.

Will It Work for Me?

Four checks that rule a Franklin drive or control box in or out before you spend time on part numbers.

Warranty

Cerus X-Drive drives and panels carry Franklin’s standard limited warranty for one year from the date of installation, and in no event more than two years from the date of manufacture, per the Cerus X-Drive Installation and Operation Manual. Franklin’s X-Drive brochure (M1789) adds that drives are eligible for an Extended Warranty when paired with a Franklin-supplied motor and pump.

For control boxes, reactors and filters, we confirm the applicable Franklin term with your quote. Full terms and conditions are in the manufacturer’s manual.

Reliability

The X-Drive trips on overvoltage, undervoltage, overcurrent, ground fault, input phase loss and output phase open, and adds pump protections such as underload, broken pipe and no-flow. Short-circuit rating is 100 kA with suitable Class J fuses. In the control boxes, the solid-state QD relay outlasts a voltage relay, and every box is built from components Franklin tests as a matched set.

Fit

Drives: the X-Drive runs three-phase induction and MagForce permanent-magnet motors; single-phase input works through UL-listed phase conversion at reduced output. At 460V and 575V, leads past 1,000 ft need a sine wave filter.

Control boxes: for Franklin single-phase 3-wire submersible motors only. A 2-wire motor has its starting parts built in and uses no box.

Match It Now

Send the motor nameplate (HP, voltage, phase, FLA or SFA), your supply voltage and phase, and the cable length. We return a matched part number and the manufacturer submittal.

Request a quote for a drive or control box
Call 1-888.510.4036
sales@watermainsupply.com

Franklin Electric Drive and Control Box Lines

Three groups cover the collection: X-Drive VFD pump panels and drives, the output and input filtering around them, and single-phase 3-wire control boxes with their replacement parts.

Franklin Electric Cerus X-Drive range of drives and pump panel

Cerus X-Drive VFD Panels & Drives

SUB panel · CEN panel · stand-alone

3–600 HPPanels, motor HP
NEMA 3RPanels, outdoor
NEMA 1Stand-alone drive
1Ph or 3PhInput

The same X-Drive in three forms. The SUB panel is set up for 4, 6 and 8 in submersible motors; the CEN panel for centrifugal and other surface pumps. Both are NEMA 3R with a circuit breaker disconnect, a line reactor or DC choke, and a dV/dt output filter at 460V and 575V. The stand-alone drive is NEMA 1 for indoor mounting or building into your own panel.

Key specs
  • Panels at 200-230V, 460V and 575V; single-phase input panels at 200-230V and 460V
  • Low-harmonic XSLH and XCLH panels at 460V, designed to IEEE-519
  • Stand-alone CXD drives from 3 A to 770 A output
  • Factory options: HOA switch, speed pot, run and fault lights, foot kit

Best forConstant-pressure wells, irrigation, municipal boosting and lift stations, VR booster pumps and panel-shop builds.

Shop X-Drive SUB Panels

Reactors, dV/dt Filters & X-Drive Accessories

Protect the motor, the supply and the drive

3% / 5%Reactor impedance
1/4–500 HPReactors, motor HP
2–750 AdV/dt filters
100/200/300psig transducers

Line reactors smooth the current a drive draws and cut harmonics on the supply. Load reactors and dV/dt filters slow the voltage rise reaching the motor, which protects winding insulation on long cable runs. Which one you need depends on voltage and the drive-to-motor distance. X-Drive accessories add pressure feedback, communications and I/O.

Key specs
  • Reactors: 200/230V, 460V and 575V; NEMA 1 or NEMA 3R; line or load duty
  • dV/dt filters: 460V and 575V, V1K series, NEMA 1 or NEMA 3R
  • 4-20 mA pressure transducers PSIG-100-20FT, PSIG-200-20FT, PSIG-300-20FT
  • Modbus TCP/IP card CMC-EIP01; FE Connect card 10000004840; I/O cards

Best forStand-alone drives, retrofits of existing panels, long submersible leads and MagForce permanent-magnet motors.

Shop dV/dt Output Filters

3-Wire Control Boxes & Parts

QD · CRC · Standard · Deluxe

1/3–15 HPMotor HP
115V / 230VSingle-phase
NEMA 3ROutdoor, IP23
UL listed60 Hz models

A Franklin 3-wire single-phase submersible motor has no starting components in the motor, so the control box supplies them: start capacitor, relay, overloads and, on some boxes, a run capacitor or line contactor. QD and CRC boxes cover 1/3 to 1 HP; Standard and Deluxe cover 1 to 15 HP. Replacement parts are listed by Franklin kit order number.

Key specs
  • QD: solid-state QD relay; lid removal disconnects the control components
  • CRC: adds a run capacitor for smoother motor operation
  • Standard: capacitor start/run with overloads, terminals to AWG 2
  • Deluxe: adds a magnetic line contactor matched to the motor rating

Best forResidential and farm wells, livestock water and replacement of a failed box or capacitor on an existing 3-wire motor.

Shop 3-Wire Control Boxes

All Products in This Collection

Product Order numbers (examples) Range
X-Drive SUB VFD Panel for Submersible Pumps XS2BH / XS4BH / XS6BH, XSLH4BH 3–550 HP; 460V low-harmonic 10–500 HP
X-Drive CEN VFD Panel for Centrifugal Pumps XC2BH / XC4BH / XC6BH, XCLH4BH 3–500 HP; 460V low-harmonic 10–600 HP
X-Drive Stand-Alone VFD CXD-005A-2V to CXD-675A-6V 3–770 A output, NEMA 1
X-Drive Accessories PSIG-100-20FT, CMC-EIP01, EMC-D42A, MKC-KPPK Transducers, cards, keypad bracket
VFD Line and Load Reactor KDR series 3% and 5%, 1/4–500 HP
VFD dV/dt Output Filter V1K2A01 to V1K750A03 2–750 A, 460V and 575V
Single-Phase 3-Wire Control Box 280 108 4915, 282 408 5015, 282 300 8110 1/3–15 HP
Control Box Replacement Parts 305 207 913, 305 101 904, 305 347 901 Capacitors, relays, overloads, contactors

X-Drive SUB vs CEN vs Stand-Alone vs 3-Wire Control Box

How the four product families in this collection differ, using Franklin literature and the order numbers listed in each product.

Feature X-Drive SUB panel X-Drive CEN panel Stand-alone X-Drive 3-wire control box
Runs 3-phase submersible motors, 4, 6 and 8 in, incl. MagForce Centrifugal and surface pump motors, e.g. VR Any variable-torque motor within its amp rating Franklin 1Ph 3-wire submersible motor
Speed control Variable Variable Variable Fixed speed, start and protect
Enclosure NEMA 3R NEMA 3R NEMA 1, open-type convertible NEMA 3R, IP23
Supply voltage 200-230V, 460V, 575V 200-230V, 460V, 575V 200-240V, 380-480V, 575V classes 115V or 230V, 60 Hz
Single-phase input 3–30 HP at 200-230V; 3–75 HP at 460V 3–30 HP at 200-230V; 3–100 HP at 460V All ratings except 575V 104 A and up, at reduced output Single-phase only
Range listed 3–550 HP 3–600 HP 3–770 A output 1/3–15 HP
Input harmonics Line reactor or DC choke included Line reactor or DC choke included DC choke built in from 50 HP at 230V, 60 HP at 460/575V —
Output filter dV/dt filter included at 460/575V dV/dt filter included at 460/575V Add load reactor or dV/dt filter by lead length —
Low-harmonic build XSLH4BH, 460V, 10–500 HP XCLH4BH, 460V, 10–600 HP — —
Disconnect Circuit breaker, service-entrance provisions Circuit breaker, service-entrance provisions Supplied by panel builder —
Factory options HOA, speed pot, pilot lights, foot kit HOA, speed pot, pilot lights Comm and I/O cards Deluxe adds magnetic contactor
Protection Underload, broken pipe, backspin timer Pipe fill, overpressure, no-flow, pump prime Same firmware as panels Overloads (Standard, Deluxe)
Communications Modbus RTU/ASCII, BACnet MS/TP Modbus RTU/ASCII, BACnet MS/TP Modbus, BACnet; optional Modbus TCP/IP, FE Connect —
Example part no. XS4BH025-3A XC4BH100-3A CXD-032A-4V 280 108 4915
Match on Motor HP, voltage, SFA Motor HP, voltage, FLA Motor amps and voltage class Motor HP, voltage, 3-wire

Ranges are the base part numbers listed in our product pages from the Franklin price list; Franklin rates the X-Drive family from 1 HP. Sources: Cerus X-Drive brochure M1789, Low Harmonics spec sheet M5055, Motors and Control Boxes Catalog M1748.

Quick rule. Three-phase motor and you want variable speed: X-Drive — SUB panel for a submersible, CEN panel for a surface pump, stand-alone drive if it goes inside your own enclosure. Single-phase 3-wire submersible at fixed speed: a Franklin control box matched to the motor HP and voltage. The one mistake we see most: choosing a drive on horsepower alone when the motor amps are higher than the drive rating.

Selection Guide: Which Franklin Drive or Control Box

Start from the job. This is guidance; we confirm the final part number against the Franklin submittal and your motor nameplate.

Application Typical need Recommended Notes
Municipal or ag well, 3-phase submersible Constant pressure or flow, outdoor pad X-Drive SUB panel dV/dt filter included at 460/575V; match 4, 6 or 8 in motor
Well on single-phase utility service Run a 3-phase submersible from 1Ph supply SUB panel, -1A input (XS2BH / XS4BH) 200-230V to 30 HP, 460V to 75 HP
VR booster or centrifugal surface pump Constant pressure, variable demand X-Drive CEN panel Add a 4-20 mA pressure transducer
Large pump, utility harmonic limits IEEE-519 compliance XSLH or XCLH low-harmonic panel 460V 3Ph, built-in passive harmonic filter
Panel shop or indoor MCC Drive only, own enclosure Stand-alone X-Drive Open type raises ambient limit to 122 °F
460/575V drive, 45–100 ft to motor Protect motor windings Load reactor Size on motor FLA and voltage
460/575V drive, 100–1,000 ft to motor Limit peak voltage at motor dV/dt output filter Past 1,000 ft: sine wave filter
MagForce permanent-magnet motor Any lead length dV/dt output filter Output filter required on PM motors; sine wave past 800 ft (M1748)
Drive on constant-pressure control Pressure feedback PSIG transducer 100, 200 or 300 psig range above max system pressure
SCADA or BMS over Ethernet; phone setup Networking, remote support CMC-EIP01 or FE Connect card FE Connect needs firmware 1.2 or later
Residential 3-wire submersible, 1/3–1 HP Simple, long-life start QD or CRC control box CRC adds a run capacitor, 1/2–1 HP
3-wire submersible, 1–15 HP Pressure or level switch control Standard or Deluxe control box Deluxe includes the line contactor
Existing box failed to start the motor Replace capacitor, relay or overload Control box parts Match to the box model number on the label

Sizing and Matching Franklin Drives and Control Boxes

Controls are matched, not guessed. Every part in this collection is chosen from the motor nameplate, the power supply and the cable run.

X-Drive: Match the Motor, Then the Supply, Then the Cable

1. Motor. X-Drive panels are horsepower-rated: the HP in the part number (XS4BH025-3A = 25 HP) should match the motor nameplate HP, and the voltage code (2 = 200-230V, 4 = 460V, 6 = 575V) the motor voltage. Stand-alone drives are amp-rated: the drive output must be at least the motor FLA, or SFA for a submersible.

2. Supply. The input suffix -3A is three-phase, -1A single-phase. On single-phase input a stand-alone drive delivers reduced output: about half the three-phase rating on smaller frames and about one third on larger frames, as listed per model.

3. Cable. Franklin’s X-Drive Quick Start for 460V and 575V: load reactor from 45 to 100 ft drive-to-motor, dV/dt filter from 100 to 1,000 ft, sine wave filter beyond that. For submersible pumps the guide calls for the dV/dt filter at 800 ft, and catalog M1748 requires an output filter on any permanent-magnet motor (dV/dt to 800 ft, sine wave beyond). Output reactors and filters are not required at 200/230V. Size power wire for less than 2% voltage drop, and use the Franklin AIM Manual for submersible cable gauge.

Worked example (stand-alone drive). 20 HP, 460V, 6 in submersible. Franklin lists a service factor amp figure of 30.3 A for this motor in the X-Drive Low Harmonics sheet M5055. Three-phase supply: CXD-032A-4V is rated 32 A, and 32 A ≥ 30.3 A, so it covers the motor. Single-phase supply: CXD-032A-4V drops to 16 A and CXD-060A-4V to 30 A, both under 30.3 A; CXD-073A-4V delivers 36.5 A on single-phase and covers it. Cable route 600 ft sits in the 100–1,000 ft band, so add a dV/dt filter rated at least 30.3 A: V1K35A03 (35 A, NEMA 3R) outdoors. The panel alternative is XS4BH020-3A, which already includes the reactor or choke and the dV/dt filter. We confirm the final selection against your motor nameplate and the Franklin submittal.

3-Wire Control Box: Match HP, Voltage and Wires

Read the motor nameplate. It must say 3-wire, single-phase. The control box HP and voltage must equal the motor HP and voltage; a box for a larger or smaller motor carries the wrong capacitor and overload values. The 220V Standard boxes on our listing (282 350 8110, 282 351 8110, 282 352 8110, 282 253 9010) are 50 Hz models in Franklin catalog M1748 — for U.S. 60 Hz service choose the 230V box.

Worked example (control box and part). 1 HP, 230V, 3-wire Franklin submersible on a pressure switch. Franklin offers the QD box 280 108 4915, the CRC box 282 408 5015 (adds a 23 MFD, 370 V run capacitor), or the Standard 282 300 8110 and Deluxe 282 300 8310 that cover 1 to 1.5 HP. If an existing QD box 280 108 4915 fails to start the motor, the M1748 parts table lists start capacitor 105-126 MFD, 220 V (kit 305 207 913) and QD relay (kit 305 101 904) for that box. Match the capacitor MFD and voltage exactly.

What to Send Us

Item Where to find it Why it matters
Motor HP and voltage Motor nameplate Sets the panel HP rating or control box model
Motor FLA or SFA Nameplate; SFA for submersibles Drives are sized on amps, not HP alone
Motor type and wires Nameplate; 2-wire or 3-wire, induction or MagForce 3-wire needs a control box; PM motors need an output filter
Supply voltage and phase Service panel or utility bill Picks -1A (single-phase) or -3A (three-phase) input
Cable run, drive to motor Measured route, including drop pipe length Load reactor, dV/dt filter or sine wave filter
Existing box or drive model Label inside the lid or on the drive Replacement parts match the box, not the motor
Serial number or date code Box label or drive nameplate Confirms revision and warranty start

Franklin X-Drive and Control Box Ratings

Documented manufacturer figures only. Motor HP is nameplate HP.

Cerus X-Drive Performance Range

Voltage Motor HP Max amps
200-208V 1–100 HP 322 A
230V 1–125 HP 322 A
480V 1–600 HP 770 A
575V 1–700 HP 675 A

Source: Franklin Electric Cerus X-Drive brochure M1789. 700 HP models are 575V only.

Low-Harmonic Panel Ratings (460V, 3-Phase)

Model Application Motor HP Rated motor amps
XSLH4BH010-3A SUB, 4 in motor 10 17.3 A SFA
XSLH4BH020-3A SUB, 6 in motor 20 30.3 A SFA
XSLH4BH060-3A SUB, 6 in motor 60 92.3 A SFA
XSLH4BH100-3A SUB, 8 in motor 100 142 A SFA
XSLH4BH200-3A SUB, 8 in motor 200 282 A SFA
XCLH4BH050-3A CEN 50 65 A FLA
XCLH4BH100-3A CEN 100 124 A FLA
XCLH4BH200-3A CEN 200 240 A FLA
XCLH4BH600-3A CEN 600 720 A FLA

Source: Cerus X-Drive Low Harmonic Pump Panels spec sheet M5055, ordering information (selected rows). SUB rows list max service factor amps by motor size; CEN rows list motor FLA.

X-Drive Drive Ratings

Rating Value
Overload, variable torque 120% of rated current for 1 min every 5 min
Overload, constant torque 150% for 1 min every 5 min; 160% for 3 s every 25 s
Short-circuit rating 100 kA with suitable Class J fuses
Operating ambient, open type 14–122 °F (-10 to 50 °C)
Altitude Full rating to 3,300 ft (1,000 m), derate above
Input efficiency 97–98% or better by frame and voltage
Control method V/F and sensorless vector; PM and MagForce control
Approvals UL508C, UL/cUL, CE

Source: Cerus X-Drive Specification Table (binder document 089) and X-Drive Quick Start.

3-Wire Control Box Specifications

Box type Frequency Motor HP Terminals Magnetic contactor Agency
QD 60 Hz 1/3–1 5, to AWG 10 No UL listed US and Canada
CRC 60 Hz 1/2–1 5, to AWG 10 No UL listed US and Canada
Standard 60 Hz 1–10 5, to AWG 2 No UL listed US and Canada
Deluxe 60 Hz 1–15 6, to AWG 2 Yes UL listed US and Canada

Source: Franklin Electric Motors and Control Boxes Catalog M1748. All boxes NEMA 3R, IP23, suitable for outdoor mounting. For drive performance at your duty point, request the Franklin submittal for your exact model.

Features That Matter on the Install

Application Firmware

Presets for submersible pumps, centrifugal pumps, cooling towers and circulating pumps load the right protections at startup, so commissioning takes minutes rather than a parameter-by-parameter build.

Multi-Pump Control

One X-Drive system coordinates up to 8 drives, with pre-PID pipe fill, a second PID loop, dual demand and pipe leak protection — the functions a booster or lift station actually uses.

Filtering Built In

Every panel has a line reactor or DC choke, and 460V and 575V panels add a dV/dt output filter recommended for leads up to about 1,000 ft. Fewer loose parts to size on site.

Low-Harmonic Option

XSLH and XCLH panels add a passive harmonic filter designed to IEEE-519, for utilities and facilities that limit supply distortion on large pumps.

Single-Phase Input

UL-listed phase conversion lets a panel run a three-phase motor from single-phase service, which opens rural wells to three-phase motors.

FE Connect App

With the optional Bluetooth card and firmware 1.2 or later: phone-based setup, commissioning reports, logs and One-to-One live support sessions with Franklin or your own team.

QD Relay and Quick Disconnect

In QD and CRC boxes the solid-state QD relay outlasts a voltage relay, and removing the lid disconnects the control components for safer troubleshooting.

Deluxe Line Contactor

Deluxe control boxes carry a magnetic line contactor matched to the motor rating, so a pressure or level switch can pilot the motor with no external contactor.

Related Franklin Electric Pumps, Motors and Parts

Drives and control boxes are one part of the system. These pages cover the pumps and motors they run.

Franklin Electric 10VR vertical multistage pump with motor and flanged connections

10VR Vertical Multistage Pump

A common load for the CEN panel on constant-pressure boosting.

Franklin Electric 10VR pump end without motor

10VR Pump End Kit

Rebuild the pump the drive runs, without the motor.

VR Series Replacement Motor

Match the drive or panel HP to the new motor nameplate.

Bare-Shaft Centrifugal Pump

Surface pump for drive-controlled transfer duty.

Repair Parts and Accessories

Seal kits, repair kits and flanges for Franklin pumps.

VR Vertical Multistage Pumps

1VR to 95VR booster pumps for X-Drive CEN panels.

Every drive, filter, control box and replacement part we supply is genuine Franklin Electric, factory-new, ordered by Franklin part or kit number so the component matches the original.

Why Buy Franklin Controls from Watermain Supply

Engineering-Led Sizing

We check drive amps, input phase, lead length and control box model against your motor nameplate before you order, and send the Franklin submittal.

Multi-Brand Perspective

We work across pump, motor and drive brands. If Franklin Electric is not the right fit, we will say so and quote the one that is.

Account Terms Available

Net-30 for qualified contractor, property-management and municipal accounts.

Parts & Aftermarket

Capacitors, relays, overloads, contactors, reactors, filters and X-Drive cards by Franklin kit number, for the equipment you already run.

Correct U.S. 60 Hz Build

We match 115V, 230V, 460V or 575V and single- or three-phase input to your service, and flag 50 Hz models before they ship.

One Order, Whole System

Pump, motor, drive, filter and control box on one order from one supplier based in Houston, serving the Gulf Coast.

Franklin Control Box and X-Drive FAQ

What warranty comes with a Franklin X-Drive?

Franklin covers the Cerus X-Drive under its standard limited warranty for one year from the date of installation, and in no event more than two years from the date of manufacture, per the Cerus X-Drive Installation and Operation Manual. Franklin also states that drives paired with a Franklin-supplied motor and pump are eligible for an Extended Warranty. Full terms and conditions are in the manufacturer's manual.

What is the difference between the X-Drive SUB and CEN panels?

Both use the same Cerus X-Drive in a NEMA 3R panel with a disconnect. The SUB panel is set up for 4, 6 and 8 in submersible motors and listed from 3 to 550 HP; the CEN panel is set up for centrifugal and surface pumps and listed from 3 to 600 HP. Choose by where the motor is: down the well or on the pad.

Can an X-Drive panel run a three-phase motor from single-phase power?

Yes. Panels with the -1A suffix take single-phase input through UL-listed phase conversion: 3 to 30 HP at 200-230V, and at 460V up to 75 HP for SUB and 100 HP for CEN panels. A stand-alone drive also runs on single-phase input at a reduced output listed for each model.

Do I need a separate line reactor with an X-Drive?

Every X-Drive panel already includes a line reactor or DC choke. The drive itself has a built-in DC choke from 50 HP at 230V and 60 HP at 460V and 575V. Below those ratings, a stand-alone drive can take a 3 or 5 percent line reactor where the supply is stiff or noisy.

When do I need a load reactor or a dV/dt filter?

At 460V and 575V, Franklin calls for a load reactor from 45 to 100 ft between drive and motor, a dV/dt filter from 100 to 1,000 ft, and a sine wave filter beyond 1,000 ft. On MagForce permanent-magnet motors an output filter is required at any length: dV/dt up to 800 ft, sine wave beyond, per catalog M1748. At 200/230V output filtering is not required.

Why does a 3-wire submersible motor need a control box?

A Franklin 3-wire single-phase motor has no starting components inside it. The control box supplies the start capacitor, relay and overload protection, and on CRC boxes a run capacitor. The box must match the motor HP and voltage on the nameplate. A 2-wire motor has its starting parts built in and uses no control box.

QD, CRC, Standard or Deluxe: which control box do I need?

QD boxes cover 1/3 to 1 HP with the solid-state QD relay. CRC boxes cover 1/2 to 1 HP and add a run capacitor for smoother operation. Standard boxes cover 1 to 10 HP at 60 Hz, and Deluxe boxes cover 1 to 15 HP and add a magnetic line contactor so no external contactor is needed.

How do I order the right control box replacement part?

Read the model number on the control box label, not the motor, and send it to us. Franklin lists every capacitor, relay, overload and contactor by kit order number against that box model. Match capacitor microfarad and voltage ratings exactly; the same microfarad rating at a different voltage is not a substitute.

How do I size a stand-alone X-Drive?

Size on motor amps, not horsepower alone. The drive rated output must be at least the motor FLA, or SFA for a submersible, in the right voltage class. On single-phase input use the reduced single-phase output listed for the model. Send us the nameplate and we confirm the drive against the Franklin submittal.

What is the lead time on X-Drive panels and control boxes?

Lead time depends on the model and configuration. Configured-to-order X-Drive panels with factory options follow Franklin build lead times, which vary. We confirm lead time on your quote before you order.

Ready to Match Your Drive or Control Box?

Send the motor nameplate, supply voltage and phase, and cable length. We return the matched Franklin part number and submittal.