Menu
Product variant with selected options does not exist!
The MAP view should only be displayed when the product vendor matches A.Y. McDonald. For all other vendors, the MAP section should remain hidden.
files/Deluxcontrolbox.png
03:50 PM
Included: the control box with its start and run capacitors, relay and overloads, and the magnetic line contactor.
Motor: a Baker 4 in single-phase three-wire motor of the same horsepower and voltage; the Models table gives the motor model each box matches.
Wiring and conduit: sized at install; the box has 1/2 in and 1 in conduit knockouts.
Baker control boxes run Baker single-phase three-wire pump and motor assemblies. The Deluxe box adds a magnetic line contactor to capacitor start and capacitor run, for 1 1/2 through 5 HP motors.
Every box has a metal casing and auxiliary contacts for control by probes, with thermal protection and an external manual reset.
Covered for 2 years from the date of manufacture or 1 year from the date of installation, whichever comes first, under A.Y. McDonald’s standard limited warranty for Baker products.
| Model | Part No. | HP | Voltage | kW | Start Capacitor | Run Capacitor | Weight |
|---|---|---|---|---|---|---|---|
| SC0413 1.5HP230VD | 6619-013 | 1 1/2 | 230V | 1.1 | 105-126 µF, 250V | 10 µF, 370V | 6 lb |
| SC0413 2HP230VD | 6619-010 | 2 | 230V | 1.5 | 105-126 µF, 250V | 20 µF, 370V | 6 lb |
| SC0413 3HP230VD | 6619-011 | 3 | 230V | 2.2 | 208-250 µF, 250V | 45 µF, 370V | 6 lb |
| SC0413 5HP230VD | 6619-016 | 5 | 230V | 3 | 270-324 µF, 250V | 80 µF, 370V | 9 lb |
Sources: Pumps by Baker catalog (Sept 2025, rev 3/26), p. 130; weights from the Baker Pumps and Accessories price list, effective 7/1/2026.
| Motor type | Baker 4 in single-phase three-wire submersible motors |
| Frequency | 60 Hz |
| Casing | Metal |
| Controls | Auxiliary contacts for control by probes; thermal protection with external manual reset |
| Dimensions (A x B x C) | 8.3 x 9.8 x 5.9 in; 5 HP: 8.3 x 15.4 x 6.3 in (B1 16.5 in) |
| App connection | None |
Source: Pumps by Baker catalog (Sept 2025, rev 3/26), p. 130.
Match the box to the motor: same horsepower and voltage, and a Baker single-phase three-wire motor. Two-wire motors need no control box; three-phase motors take a starter kit instead.
| Box Model | Starting Capacitor | Running Capacitor | Starting Overload | Running Overload | Control Relay | Contactor |
|---|---|---|---|---|---|---|
| SC0413 1.5HP230VD | 3132-665 | 3132-673 | 3132-681 | 3132-689 | 3132-697 | 3132-705 |
| SC0413 2HP230VD | 3132-667 | 3132-675 | 3132-683 | 3132-691 | 3132-699 | 3132-707 |
| SC0413 3HP230VD | 3132-669 | 3132-677 | 3132-685 | 3132-693 | 3132-701 | 3132-709 |
| SC0413 5HP230VD | 3132-671 | 3132-679 | 3132-687 | 3132-695 | 3132-703 | 3132-711 |
Starting Capacitor · Running Capacitor · Starting Overload · Running Overload · Control Relay · Contactor
Replacement part numbers from the Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 130 and 343. These parts fit Baker control boxes only.
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.
Sign up for our newsletter and be the first to know about coupons and special promotions.
© 2026, Watermainsupply