Included: the motor with its lead; lead length per model is in the Models table.
Pump end required, ordered separately: a Baker pump end of the same horsepower with a NEMA 8 in motor bracket.
Motor control: Three-phase motors need a starter kit or drive. Overload protection must be provided by the user.
Drop cable and splice kit: sized to your setting depth and ordered separately.
Baker’s 8 in asynchronous two-pole submersible motors run from 40 to 150 HP. They are the rewindable type: the copper, PVC-insulated stator sits in an AISI 304 stainless steel outer shell, with painted cast iron supports and an 8 in NEMA shaft end.
A Kingsbury-type thrust bearing with graphite tilting pads and a ceramic disc carries the load, and a ceramic and carbon mechanical seal closes the motor. Overload protection must be provided by the user.
Covered for 3 years from the date of manufacture under A.Y. McDonald’s published terms for Baker submersible motors. The terms add a 5-year term from the date of manufacture for Baker submersible motors, including assembled pumps with pump ends up to 25 GPM, in potable water applications.
One motor per pump end, matched by horsepower. Need more head or flow later? Pair a larger pump end with the matching larger motor: Baker 8 in motors run from 40 to 150 HP in this listing, all on the same NEMA 8 in flange.
| Model | Part No. | HP | Power | kW | Service Factor | Rated Amps | SF Amps | Downward Thrust | Lead | Length | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SM0833 40HP460V | 3132-716 | 40 | 460V 3Ph | 30 | 1.15 | 51 A | 58.7 A | 10100 lbf | 13 ft | 41.6 in | 284 lb |
| SM0833 50HP460V | 3132-717 | 50 | 460V 3Ph | 37 | 1.15 | 61.4 A | 70.6 A | 10100 lbf | 13 ft | 43.9 in | 305 lb |
| SM0833 60HP460V | 3132-718 | 60 | 460V 3Ph | 45 | 1.15 | 74.8 A | 86.0 A | 10100 lbf | 13 ft | 47.3 in | 326 lb |
| SM0833 75HP460V | 3132-719 | 75 | 460V 3Ph | 55 | 1.15 | 90.2 A | 103.7 A | 10100 lbf | 13 ft | 50.6 in | 396 lb |
| SM0833 100HP460V | 3132-720 | 100 | 460V 3Ph | 75 | 1.15 | 123.1 A | 141.6 A | 10100 lbf | 13 ft | 54.7 in | 431 lb |
| SM0833 125HP460V | 3132-721 | 125 | 460V 3Ph | 92 | 1.15 | 152.8 A | 175.7 A | 10100 lbf | 13 ft | 60.5 in | 483 lb |
| SM0833 150HP460V | 3132-722 | 150 | 460V 3Ph | 110 | 1.15 | 182.6 A | 210.0 A | 10100 lbf | 13 ft | 63 in | 538 lb |
Electrical, thrust and lead figures from the catalog motor tables; length and weight from the catalog dimension tables by horsepower. — where the catalog prints no figure. Sources: Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 185-187, 194-195; Baker Pumps and Accessories price list, effective 7/1/2026.
| Included | Motor with lead |
| Flange | NEMA 8 in |
| Insulation class | Y |
| Degree of protection | IP68 |
| Cooling flow past the motor | 0.66 ft/sec (40-75 HP); 1.64 ft/sec (100-150 HP) |
| Voltage tolerance | +10% |
| Maximum starts | 15 per hour (40-100 HP); 10 per hour (125-150 HP) |
| Maximum operating depth | 984 ft |
| Maximum operating pressure | 425 PSI |
| Water temperature rating | 85°F |
| Speed | Two-pole, about 3450 RPM at 60 Hz |
| Frequency | 60 Hz |
| App connection | None |
Source: Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 185-187, 194-195.
A submersible motor is sized to the pump end: the same horsepower, the same flange, and enough downward thrust capacity for the pump. The figures below are the catalog electrical data, for sizing the breaker, starter or drive and the drop cable.
| HP | Power | Efficiency (%) | Power Factor | Locked Rotor / Rated Amps | Lead Conductors |
|---|---|---|---|---|---|
| 40 | 460V 3Ph | 82 | 0.86 | 4.7 | 3x16+1x6 |
| 50 | 460V 3Ph | 84 | 0.86 | 4.7 | 3x16+1x6 |
| 60 | 460V 3Ph | 84 | 0.86 | 4.7 | 3x16+1x6 |
| 75 | 460V 3Ph | 84 | 0.87 | 4.7 | 3x16+1x6 |
| 100 | 460V 3Ph | 84 | 0.86 | 4.7 | 3x25+1x25 |
| 125 | 460V 3Ph | 84 | 0.86 | 4.4 | 3x25+1x25 |
| 150 | 460V 3Ph | 84 | 0.86 | 4.4 | 3x25+1x25 |
Electrical data at 60 Hz as printed. Source: Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 185-187, 194-195.
| Well size | Built for 8 in diameter or larger water wells |
| Cooling | 0.66 ft/sec (40-75 HP); 1.64 ft/sec (100-150 HP) of water flow past the motor |
| Water temperature | Rated to 85°F |
| Starts | 15 per hour (40-100 HP); 10 per hour (125-150 HP) |
| Setting depth | Up to 984 ft operating depth; up to 425 PSI operating pressure |
| Control | Three-phase motors need a starter kit or drive |
| Voltage | Match voltage and phase to your service; tolerance +10% |
| Application | Water wells; the manufacturer excludes use in swimming areas |
| Shaft | Stainless steel |
| Shaft end | Stainless steel AISI 304 |
| Mechanical seal | Ceramic and carbon |
| Bearing ring | Carbon |
| Cable | NBR |
| Structural parts | Cast iron |
| External sleeve | Stainless steel AISI 304 |
| Thrust bearing, rotating | Carbon with antimony |
| Thrust bearing, stationary | AISI 420 |
| Diaphragm | NBR-EPDM |
| Bolts and screws | Stainless steel AISI 304 |
Source: Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 185-187, 194-195.