Included: the pump with stainless steel housing and cast iron base, carrying handle, 25 ft cord and, on the CTEFH25 models, a tethered float switch.
Float or control panel required on the 5050CUEFH25, ordered separately. Use a piggyback float or a dosing control panel.
Sized at install: pump tank, check valve and discharge pipe.
This pump features a stainless steel housing and a cast iron base, built-in thermal overload protection and a permanent split capacitor, continuous-duty motor. A carrying handle is attached.
Covered for 3 years from the date of installation under Baker Manufacturing’s published limited warranty (A.Y. McDonald Pumps & Accessories price list, effective 7/1/26). Per Baker’s terms, the warranty does not cover failure caused by sand or abrasive materials in the water.
Single pump. For heads above 50 ft see the 1/2 to 2 HP high head effluent pumps (to 123 ft).
| Model | Part No. | HP | Switch | Amps | Max Head | Max Flow | Weight |
|---|---|---|---|---|---|---|---|
| 5040CTEFH25 | 6191-125 | 4/10 | Tethered | 7.5 | 35 ft | 78 GPM | 26 lb |
| 5050CTEFH25 | 6191-127 | 1/2 | Tethered | 12 | 50 ft | 100 GPM | 31 lb |
| 5050CUEFH25 | 6191-126 | 1/2 | No switch | 12 | 50 ft | 100 GPM | 29 lb |
Source: A.Y. McDonald Pumps by Baker catalog, rev 3/26, and Pumps & Accessories price list, effective 7/1/26.
| Voltage | 120V, 1 phase, 60 Hz |
| Construction | Cast iron / stainless steel |
| Discharge | 2 in or 1-1/2 in FNPT with adapter |
| Solids | 3/4 in |
| Cord | 25 ft |
| Total head → | 0 ft | 5 ft | 10 ft | 15 ft | 20 ft | 25 ft | 30 ft | 35 ft | 40 ft | 45 ft | 50 ft |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 5040CTEFH25 | 78 | 69 | 60 | 50 | 41 | 29 | 18 | 5 | — | — | — |
| 5050CUEFH25 / 5050CTEFH25 | 100 | 91 | 82 | 72 | 63 | 54 | 44 | 34 | 25 | 16 | 7 |
Gallons per minute at each total head, as printed by A.Y. McDonald. Total head is the vertical lift from the water level to the highest point of the discharge, plus pipe and fitting friction. A dash is a head the pump does not reach. Source: A.Y. McDonald Pumps by Baker catalog, rev 3/26, p. 310.
| Water | Septic effluent and gray water with up to 3/4 in solids. Non-potable. |
| Head | Up to 35 ft (4/10 HP) or 50 ft (1/2 HP). |
| Power | 120V single phase. |
| Pairing | Single pump. |
| Housing | Stainless steel |
| Base | Cast iron |
| Impeller | Stainless steel vortex |
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.