Menu
The world's first fully integrated, intelligent submersible wastewater pumping system — clog-free performance, IE4 energy efficiency, and adaptive control with the variable-speed drive built inside the pump. Models 6020 and 6030, plus retrofit upgrades for existing stations.
The Flygt Concertor is not a conventional pump with a drive bolted on. The power electronics that run its IE4 permanent-magnet motor live inside the pump unit, so it self-adjusts across a broad performance field without external VFD cabinets or impeller trimming. The result is clog-free wastewater pumping, lower lifecycle cost, and dramatically simpler selection across municipal, commercial, and industrial lift stations.
It is part of our authorized Xylem and Flygt pump lineup. For dewatering and drainage submersibles, see our Flygt dewatering pumps.
Concertor combines advanced software with state-of-the-art hardware to protect against unscheduled downtime, eliminate nuisance clog callouts, and cut energy use — while keeping setup and operation simple.
User-adjustable performance with self-monitoring anti-clogging countermeasures helps prevent motor failure, clogging, and overflows.
Engineered to start pumping instantly in on/off systems. Advanced configurations with gateways, SCADA, or Nexicon arrive pre-programmed for a fast launch.
Virtually eliminates unplanned site visits and reduces pump and parts inventory. Built from efficient, long-life components.
Tunes to precise duty points and, with Nexicon, draws the least power possible — lowering the station's overall carbon footprint.
Four technologies do the heavy lifting — together delivering the clog-free, energy-efficient, low-touch operation the Concertor is known for.

Concertor Cutaway — Adaptive N Hydraulic & Integrated Drive
The drive is built into the pump. One unit covers a broad performance field, self-adjusting to changing flow and head — no external VFD, no cabinet cooling, no VFD trips on hot days.
The semi-open N-hydraulic guides rags, wipes, and fibrous solids through the pump. On sensing a clog, it runs an automatic cleaning sequence and resumes — ending vacuum-truck callouts.
A synchronous PM motor delivers the highest efficiency class, running cool with liquid-free or closed-loop conduction and finding the most efficient operating point each duty cycle.
Plug-in double mechanical seal with Active Seal, plus leakage and dual temperature sensors. Always-correct rotation means the pump is impossible to wire backwards.
Figures published by Xylem across deployed Concertor systems. Actual results depend on station conditions and configuration.
Start with the intelligent pump and scale the control layer to the station. Energy minimizing, multi-pump coordination, and sump and pipe cleaning are XPC-tier functions — know what each tier unlocks before you spec.

Scalable Control — Gateway, HMI & Nexicon Options
Start Here — The Smart Pump
For high-solids sites where clogs are constant — airports, residential communities, universities. Standalone on/off duty with constant power, soft start, clog detection, and automatic pump cleaning built in. Accepts a 4–20 mA signal or simple run command from third-party controllers.
Add Gateway — SCADA Integration
For systems that already have process-control algorithms and need an affordable way to use them. Gateways find the optimal duty point per pump, cutting operating costs and site visits. Modbus RTU/TCP, optional HMI. A strong fit for limited CapEx/OpEx budgets or tight cabinet space.
Add Xylem HMI + Nexicon — Full Station Control
For a complete overhaul. Concertor with MultiSmart powered by Nexicon ships pre-programmed with pump-station logic: manages up to four pumps, energy minimizer, sump and pipe cleaning, DNP3 and IEC-104, and ISA/IEC 62443-4-1 cybersecurity. Customizable via Codesys.
Both share the same intelligence, Adaptive N hydraulics, and PM IE4 motor. The 6020 covers small-to-mid stations; the 6030 steps up to higher power, an 8 in discharge, and roughly half again the head and flow. Confirm exact ratings and approvals at time of quote.

Concertor 6020 — 3.0 to 10.0 HP

Concertor 6030 — 11 to 18 HP
| Parameter | Concertor 6020 | Concertor 6030 |
|---|---|---|
| Rated Power | 3.0 to 10.0 HP (2.2–7.3 kW) | 11 to 18 HP (8.2–13.4 kW) |
| Voltage | 200–240 V and 380–480 V | 400–480 V |
| Discharge Sizes | 3, 4, 6 in (80, 100, 150 mm) | 3, 4, 6, 8 in (80, 100, 150, 200 mm) |
| Max Head (approx) | Up to ~130 ft | Up to ~200 ft |
| Max Flow (approx) | Up to ~1,900 US gpm | Up to ~2,500 US gpm |
| Speed Range | 500–3000 rpm (LV); 500–3600 rpm (HV) | 800–3000 rpm |
| Motor | PM synchronous, IE4 (IEC/TS 60034-30-2), 50/60 Hz | PM synchronous, IE4 (IEC/TS 60034-30-2), 50/60 Hz |
| Hydraulic / Impeller | Adaptive N; Hard-Iron or duplex SS | Adaptive N; Hard-Iron or duplex SS |
| Seal System | Plug-in double mechanical seal, Active Seal (WCCR/WCCR or RSiC/WCCR) | Plug-in double mechanical seal, Active Seal (WCCR/WCCR or RSiC/WCCR) |
| Cooling System | Liquid-free heat-conduction | Closed-loop cooling |
| Cable | Screened SUBCAB, 30 / 50 / 60 / 100 ft | Screened SUBCAB, 30 / 50 / 60 / 100 ft |
| Sensors | Stator-housing leakage + two temp sensors | Inspection-chamber leakage + two temp sensors + cable-cut protection |
| Approvals | CE, FM, ATEX, IECEx, CSA, UKCA, UKEX | CE, CSA, UKCA |
| Typical Fit | Small-to-mid lift stations, commercial buildings | Mid-to-large municipal and high-flow industrial |

6020 Performance Field — N080 / N100 / N150

6030 Performance Field — N080 / N100 / N150 / N200
Hazardous-location ratings (FM, ATEX, IECEx) are listed for the 6020. If your application is in a classified or explosive environment, confirm the rated configuration for the 6030 before specifying. We provide engineering-led sizing to match either model to your duty point, voltage, and installation type.
A conventional submersible wins on sticker price. The Concertor wins on lifecycle cost — energy, callouts, and inventory. Here is where the difference shows up.
| Consideration | Conventional Submersible | Flygt Concertor |
|---|---|---|
| Speed Control | Fixed speed, or external VFD cabinet | Variable speed integrated in the pump |
| Motor | Induction | Permanent-magnet, IE4 efficiency |
| Clog Handling | Manual clearing, vacuum-truck visits | Automatic detection and self-cleaning |
| Selection | Exact duty point, impeller trims | Broad self-adjusting performance field |
| Inventory | Many model and impeller-trim SKUs | Few SKUs cover the range |
| Control Panel | Separate VFD; may need cabinet cooling | No external VFD; no VFD heat trips |
| Setup | Engineered wiring, rotation checks | Set-up wizard; cannot be wired backwards |
| Lifecycle Cost | Lower CapEx, higher OpEx | Higher CapEx, lower OpEx |
Anywhere solids-laden flow threatens conventional impellers — from a single commercial wet well to a multi-pump municipal station.
Documented Concertor XPC deployments reported by Xylem.
A 40-plus-year-old station could no longer handle resident volume or solids, driving up energy, maintenance, and labor costs. Replaced with a Concertor XPC system using a control building, valve vault, and TOP sump insert.
Recurring pump failure and flooding plagued the port. A Concertor XPC system with Avensor cloud monitoring was integrated into the port's existing SCADA.
A utility serving 5.4 million people across 30,000-plus miles of pipe needed to cut callouts and operating cost under a net-zero pledge. A turnkey Concertor XPC solution with a level pressure transducer delivered.
“We've improved our overall pumping performance, but also reduced our energy bill by 53% at one of our pumping stations.”
“We used to call the vacuum truck once a month to manually remove sediment and grease. That is now a thing of the past.”
You don't need a new station to get Concertor intelligence. Retrofit DP and XPC kits connect to a Flygt Concertor N pump, adding gateway, HMI (touchscreen or basic), and Nexicon control to existing infrastructure.
Built-in pump cleaning and integrated sump and pipe cleaning end manual station cleaning and nuisance clog service calls, improving operator safety.
Adaptive flow automatically targets the optimal speed. Xylem cites at least 25% energy savings on retrofit, with quick ROI and no VFD trips on hot days.
Pre-engineered with a set-up wizard for quick start-up. Impossible to wire backwards, and compatible with third-party controllers via 4–20 mA or a simple run command.
Clog-free guarantee for 24 months and an extended system warranty of 5 years apply to qualifying Concertor system configurations.
Download the manufacturer literature. Contact us for full submittals, curves, and quote-specific data sheets.
Full authorized Xylem and Flygt dealer — genuine product, factory warranty, supported service.
We match the 6020 or 6030 to your duty point, voltage, and installation type. The right configuration the first time.
Lift stations, dry pits, high-solids industrial flow, and full station overhauls — we map the right pump and control tier to the job.
Talk to a person who knows the product. Fast quotes, clear lead times, and aftermarket support.
Send us your flow, head, voltage, and installation type. We'll return an engineering-led sizing and pricing — for a new station, a single pump, or a retrofit of what you already run.