Included: the control box with its start and run capacitors, relay and overloads.
Motor: a Baker 4 in single-phase three-wire motor of the same horsepower and voltage; the Models table gives the motor model each box matches.
Wiring and conduit: sized at install; the box has 1/2 in and 1 in conduit knockouts.
Baker control boxes run Baker single-phase three-wire pump and motor assemblies. The Standard capacitor start and run box covers 1 1/2 through 5 HP motors.
Every box has a metal casing and auxiliary contacts for control by probes, with thermal protection and an external manual reset.
Covered for 2 years from the date of manufacture or 1 year from the date of installation, whichever comes first, under A.Y. McDonald’s standard limited warranty for Baker products.
| Model | Part No. | HP | Voltage | kW | Start Capacitor | Run Capacitor | Weight |
|---|---|---|---|---|---|---|---|
| SC0413 1.5HP230VS | 6619-017 | 1 1/2 | 230V | 1.1 | 105-126 µF, 250V | 10 µF, 370V | 6 lb |
| SC0413 2HP230VS | 6619-006 | 2 | 230V | 1.5 | 105-126 µF, 250V | 20 µF, 370V | 6 lb |
| SC0413 3HP230VS | 6619-007 | 3 | 230V | 2.2 | 208-250 µF, 250V | 45 µF, 370V | 7 lb |
| SC0413 5HP230VS | 6619-008 | 5 | 230V | 3 | 270-324 µF, 250V | 80 µF, 370V | 6 lb |
Sources: Pumps by Baker catalog (Sept 2025, rev 3/26), p. 130; weights from the Baker Pumps and Accessories price list, effective 7/1/2026.
| Motor type | Baker 4 in single-phase three-wire submersible motors |
| Frequency | 60 Hz |
| Casing | Metal |
| Controls | Auxiliary contacts for control by probes; thermal protection with external manual reset |
| Dimensions (A x B x C) | 8.3 x 9.8 x 5.9 in |
| App connection | None |
Source: Pumps by Baker catalog (Sept 2025, rev 3/26), p. 130.
Match the box to the motor: same horsepower and voltage, and a Baker single-phase three-wire motor. Two-wire motors need no control box; three-phase motors take a starter kit instead.
| Box Model | Starting Capacitor | Running Capacitor | Starting Overload | Running Overload | Control Relay | Contactor |
|---|---|---|---|---|---|---|
| SC0413 1.5HP230VS | 3132-664 | 3132-672 | 3132-680 | 3132-688 | 3132-696 | 3132-704 |
| SC0413 2HP230VS | 3132-666 | 3132-674 | 3132-682 | 3132-690 | 3132-698 | 3132-706 |
| SC0413 3HP230VS | 3132-668 | 3132-676 | 3132-684 | 3132-692 | 3132-700 | 3132-708 |
| SC0413 5HP230VS | 3132-670 | 3132-678 | 3132-686 | 3132-694 | 3132-702 | 3132-710 |
Starting Capacitor · Running Capacitor · Starting Overload · Running Overload · Control Relay · Contactor
Replacement part numbers from the Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 130 and 343. These parts fit Baker control boxes only.
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.
Sign up for our newsletter and be the first to know about coupons and special promotions.
© 2026, Watermainsupply