Taco SmartDrive Basic Variable Frequency Drive - 1/3 to 125 HP, 3 Phase

Supply Voltage: 200-240V 3 ph
HP Range - Frame: 1/3-2 HP - Frame H1

Product variant with selected options does not exist!

Price
$1,631.28
Coupon 5% off applied automatically in your cart. No code needed.
SKU: TACO-SDB-H1-200
Weight : 4.6 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Taco · Variable Frequency Drive, Basic
SmartDrive Basic
21 builds: 1/3 to 60 HP at 200-240V, 1/2 to 125 HP at 380-480V, 3 to 125 HP at 525-600V.
Variable Frequency Drive for Pumps
200-240V / 380-480V / 525-600V Supply
IP20 / NEMA 1 Kit
BACnet, Modbus RTU, N2, FLN Built In
Dual DC-Link Chokes (5% Reactor Equivalent)
IEEE 519-1992 Support
+TSL Pump Logic Option
4.6-112.4 lb Weight
Overview

The SmartDrive Basic is Taco’s economical variable frequency drive for pumps, built on the Danfoss VLT HVAC Basic platform. It has the common HVAC building automation protocols, a PI controller and a Smart Logic Controller built in, with fire override, sleep mode and automatic energy optimization that Taco rates at a further 5 to 15% energy saving. The single enclosure has no forced air flow over the electronics and runs at up to 50°C ambient.

  • Built-in BACnet MS/TP, Modbus RTU, N2 Metasys, FLN Apogee and FC protocol
  • Built-in PI controller and Smart Logic Controller; flying start and auto restart
  • Integrated dual DC-link choke, equal to a 5% AC line reactor, supporting IEEE 519-1992
  • Start-up wizard, alphanumeric display with Hand-Off-Auto keys, thermistor input
What Ships and What It Needs to Run

Included: the drive.

Set when you order: motor HP, voltage and full load amps; the +TSL pump control option and any option cards.

Wiring: line, motor and control wiring, disconnect and branch protection to code, provided on site.

Ships: about 4.6-112.4 lb by frame.

Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
Taco Warranty

Covered by Taco’s limited warranty. The Taco documents for this product do not state the term; ask us and we will confirm the current Taco terms before you order.

Specifications
Drive Danfoss VLT HVAC platform, supplied and supported by Taco
Supply frequency 50/60 Hz
Displacement power factor Above 0.98
I/O 4 programmable digital inputs, 2 analog inputs, 2 analog outputs, 2 relays (240 VAC 2 A / 400 VAC 2 A)
Output 0-100% of supply voltage; 0-400 Hz; ramps 1-3,600 s
Enclosure IP20, with NEMA Type 1 / IP21 kit
Ambient Up to 50°C (122°F)
EMC Built-in filter, protection class C1, C2 or C3

From the Taco submittal data sheets, catalog and instruction sheets.

Frames, HP and Voltage

Each build on this listing is one frame size at one supply voltage, covering the motor HP range shown. Tell us the motor HP, voltage and full load amps and we will set the drive to the motor.

Frame 200-240V 3 ph 380-480V 3 ph 525-600V 3 ph Max weight
H1 1/3-2 HP 1/2-2 HP — 4.6 lb
H2 3 HP 3-5 HP — 7.5 lb
H3 5 HP 7.5-10 HP — 9.9 lb
H4 7.5-10 HP 15-20 HP — 17.4 lb
H5 15 HP 25-30 HP — 20.9 lb
H6 20-25 HP 40-60 HP 30-40 HP 54 lb
H7 30-40 HP 75-100 HP 60-75 HP 79.4 lb
H8 50-60 HP 125 HP 100-125 HP 112.4 lb
H9 — — 3-10 HP 14.6 lb
H10 — — 15-20 HP 26.5 lb

From the Taco SmartDrive Basic catalog 300-37 and submittal 301-2130. Weight is the maximum for the frame.

Before You Buy — The Limits That Decide the Fit
Motor Pick the frame whose HP range at your supply voltage covers the motor nameplate HP
Supply Three phase supply as listed; check the voltage before ordering
Location Indoor unless the enclosure rating says otherwise; keep within the ambient limits in the specifications
Control Add the +TSL option for factory-programmed Delta-P, Delta-T or domestic booster pump control
Installation Notes
  • Install, wire and start up the drive per the Taco SmartDrive IOM and the Danfoss VLT manuals in the Data Sheet tab
  • Complete the Taco SmartDrive start-up checklist at commissioning
  • Size the line protection and wiring to the drive input current and local code
  • Run the start-up wizard or quick menu to enter the motor nameplate data before running the pump

From the Taco SmartDrive +TSL IOM 302-370 and the Danfoss VLT HVAC Basic quick start guide.

Applications

Variable speed control of HVAC and domestic water pumps: Delta-P and Delta-T hydronic pumping and domestic water booster sets, 1 to 3 pumps with lead / lag.

For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

You May Also Like