Taco · SelfSensing End Suction Pump, Base-Mounted
SFI Series
346 US builds: 29 pump sizes, 1 1/2-200 HP, 2 to 10 in flanges, 1760 to 3500 RPM, 60 Hz.
1 1/2-200 HP Variable Speed
1760 or 3500 RPM, 60 Hz
2 to 10 in Flanges
SelfSensing Drive, No Remote Sensors
175 psig Std, 300 psig with 250# Flanges
250°F Max Liquid
Bronze-Fitted, NSF 61 Option
DOE PEI 0.81-0.96
30-74 x 14.2-25.2 x 13.3-26.6 in
202-3647 lb Weight
Overview
The SFI is Taco’s SelfSensing end suction pump, base-mounted. It is the FI pump paired with a Taco variable frequency drive running SelfSensing ProBalance software. The drive reads the pump’s own operating point, so it needs no remote sensors or extra wiring, and it lets the installer balance the system by reducing pump speed rather than throttling a valve. One pump serves constant flow chiller and boiler duty or secondary variable flow duty. Each build on this listing is one pump size at one speed with one motor and drive HP; Taco trims the impeller to your duty point when the pump is ordered.
- Control modes: constant flow, variable flow (flow compensation), constant pressure and duplex standby alternation
- BACnet, Modbus RTU, N2 Metasys, FLN Apogee and FC protocol standard
- Alerts with optional shutdown for no-flow, dry-run and end-of-curve operation
- Dual DC-link chokes (equal to a 5% AC line reactor), supporting IEEE 519-1992
What Ships and What It Needs to Run
Included: the FI pump and its NEMA T-frame motor, mounted and aligned on a common steel base, with coupling and coupling guard. The Taco SelfSensing variable frequency drive ships with it, mounted on the pump or for wall mounting.
Set when you order: the impeller diameter for your duty point, motor and drive voltage.
Foundation and grout: a concrete pad, anchor bolts and grout, provided on site.
Ships by freight: about 202-3647 lb by build; plan for a lift at delivery.
Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty
Covered for 1 year from start-up or 18 months from shipment, whichever comes first, under Taco’s limited warranty for commercial pumps. Taco states that the motor is warranted by the motor manufacturer and that seals are not covered.
Specifications
| Pump type |
Single-stage end suction volute pump, frame-mounted on a steel base, rear pull-out |
| Motor |
NEMA standard T-frame motor, ODP or TEFC by build |
| Speed |
1760 or 3500 RPM by build, 60 Hz |
| Connections |
ANSI Class 125 flanges (standard) or Class 250, 2 to 10 in |
| Maximum working pressure |
175 psig with Class 125 flanges; 300 psig with Class 250 flanges |
| Maximum liquid temperature |
250°F |
| Mechanical seal |
Mechanical seal, ceramic / EPT standard |
| Pump energy index |
DOE PEI 0.81-0.96 by build |
| Drive |
Taco variable frequency drive with SelfSensing ProBalance |
| Control modes |
Constant flow, variable flow (flow compensation), constant pressure, duplex standby alternation |
| Communication |
BACnet, Modbus RTU, N2 Metasys, FLN Apogee, FC protocol (standard); LonWorks, DeviceNet, Profibus (optional) |
| Drive I/O |
6 digital inputs, 2 digital outputs, 1 analog current output, 2 analog inputs, 2 pulse inputs, 2 Form C relays |
| Harmonic suppression |
Dual DC-link chokes, equal to a 5% AC line reactor; supports IEEE 519-1992 |
| Drive ambient |
-14 to 113°F up to 3,300 ft |
| Drive enclosure |
NEMA Type 1 or NEMA Type 12 by build |
From the Taco submittal data sheets, catalog and IOM.
Models & Performance — Will It Do What You Need?
Each block is one flange size at one speed. Every row is one pump size this listing sells, with the motor HP range Taco offers for it, and every figure is the total head in feet the pump adds at the flow heading the column, on the largest impeller Taco offers for that size. Taco trims the impeller to the duty point you order, which brings the curve down to it; the full family of impeller curves for each size is in the image gallery. The SelfSensing drive runs the pump at any speed up to this full-speed curve and follows the system from there.
SFI 2 x 1-1/4 in, 1760 RPM: 1206D, 1207D, 1 1/2-2 HP, 40-58 ft shut-off, 134 GPM
| Model, motor |
0 GPM |
65 |
100 |
134 (Max) |
| 1206D, 1 1/2 HP |
40 |
36 |
25 |
— |
| 1207D, 1 1/2-2 HP |
58 |
54 |
48 |
37 |
SFI 2 x 1-1/4 in, 3500 RPM: 1206D, 1207D, 3-15 HP, 161-230 ft shut-off, 215 GPM
| Model, motor |
0 GPM |
110 |
160 |
215 (Max) |
| 1206D, 3-10 HP |
161 |
149 |
129 |
— |
| 1207D, 7 1/2-15 HP |
230 |
221 |
206 |
180 |
SFI 2-1/2 x 1-1/2 in, 1760 RPM: 1506D, 1507D, 1509D, 2007D, 2009D, 1 1/2-10 HP, 41-101 ft shut-off, 347 GPM
| Model, motor |
0 GPM |
175 |
260 |
347 (Max) |
| 1506D, 1 1/2-2 HP |
41 |
— |
— |
— |
| 1507D, 1 1/2-3 HP |
57 |
38 |
— |
— |
| 1509D, 2-7 1/2 HP |
101 |
80 |
— |
— |
| 2007D, 1 1/2-3 HP |
54 |
45 |
27 |
— |
| 2009D, 3-7 1/2 HP |
97 |
88 |
73 |
38 |
SFI 2-1/2 x 1-1/2 in, 3500 RPM: 1506D, 1507D, 1509D, 2007D, 2009D, 5-60 HP, 159-399 ft shut-off, 582 GPM
| Model, motor |
0 GPM |
290 |
435 |
582 (Max) |
| 1506D, 5-15 HP |
159 |
102 |
— |
— |
| 1507D, 7 1/2-20 HP |
226 |
176 |
— |
— |
| 1509D, 15-50 HP |
399 |
343 |
— |
— |
| 2007D, 10-25 HP |
212 |
188 |
141 |
— |
| 2009D, 20-60 HP |
379 |
361 |
319 |
245 |
SFI 3 x 2-1/2 in, 1760 RPM: 2506D, 2507D, 2509D, 2511D, 2513D, 1 1/2-30 HP, 40-189 ft shut-off, 470 GPM
| Model, motor |
0 GPM |
235 |
355 |
470 (Max) |
| 2506D, 1 1/2-2 HP |
40 |
16 |
— |
— |
| 2507D, 3-5 HP |
51 |
46 |
34 |
— |
| 2509D, 3-10 HP |
95 |
87 |
71 |
— |
| 2511D, 5-15 HP |
132 |
117 |
92 |
— |
| 2513D, 10-30 HP |
189 |
183 |
166 |
132 |
SFI 3 x 2-1/2 in, 3500 RPM: 2506D, 2507D, 2509D, 5-75 HP, 157-376 ft shut-off, 904 GPM
| Model, motor |
0 GPM |
450 |
680 |
904 (Max) |
| 2506D, 5-15 HP |
157 |
67 |
— |
— |
| 2507D, 20-40 HP |
205 |
189 |
148 |
— |
| 2509D, 30-75 HP |
376 |
349 |
290 |
188 |
SFI 4 x 3 in, 1760 RPM: 3007D, 3009D, 3011D, 3013D, 3-40 HP, 51-194 ft shut-off, 921 GPM
| Model, motor |
0 GPM |
460 |
690 |
921 (Max) |
| 3007D, 3-7 1/2 HP |
51 |
33 |
— |
— |
| 3009D, 5-15 HP |
93 |
79 |
56 |
— |
| 3011D, 10-20 HP |
126 |
111 |
84 |
— |
| 3013D, 15-40 HP |
194 |
178 |
147 |
79 |
SFI 4 x 3 in, 3500 RPM: 3007D, 3009D, 15-125 HP, 203-362 ft shut-off, 1,438 GPM
| Model, motor |
0 GPM |
720 |
1,080 |
1,438 (Max) |
| 3007D, 15-40 HP |
203 |
167 |
84 |
— |
| 3009D, 40-125 HP |
362 |
334 |
282 |
193 |
SFI 5 x 4 in, 1760 RPM: 4007D, 4009D, 4013D, 5-60 HP, 48-192 ft shut-off, 1,324 GPM
| Model, motor |
0 GPM |
660 |
990 |
1,324 (Max) |
| 4007D, 5-60 HP |
48 |
34 |
— |
— |
| 4009D, 7 1/2-20 HP |
87 |
77 |
53 |
— |
| 4013D, 20-60 HP |
192 |
181 |
158 |
120 |
SFI 5 x 4 in, 3500 RPM: 4007D, 25-60 HP, 189 ft shut-off, 1,581 GPM
| Model, motor |
0 GPM |
790 |
1,190 |
1,581 (Max) |
| 4007D, 25-60 HP |
189 |
179 |
145 |
80 |
SFI 6 x 5 in, 1760 RPM: 5009D, 5011D, 5013D, 5-75 HP, 82-189 ft shut-off, 1,914 GPM
| Model, motor |
0 GPM |
960 |
1,440 |
1,914 (Max) |
| 5009D, 10-25 HP |
82 |
73 |
49 |
— |
| 5011D, 15-40 HP |
116 |
103 |
69 |
— |
| 5013D, 25-75 HP |
189 |
177 |
148 |
93 |
SFI 8 x 6 in, 1760 RPM: 6009D, 6011D, 6013D, 20-125 HP, 82-186 ft shut-off, 3,234 GPM
| Model, motor |
0 GPM |
1,620 |
2,450 |
3,234 (Max) |
| 6009D, 20-40 HP |
82 |
73 |
— |
— |
| 6011D, 25-60 HP |
116 |
105 |
70 |
— |
| 6013D, 40-125 HP |
186 |
178 |
147 |
85 |
SFI 10 x 8 in, 1760 RPM: 8013D, 50-200 HP, 184 ft shut-off, 4,760 GPM
| Model, motor |
0 GPM |
2,400 |
3,550 |
4,760 (Max) |
| 8013D, 50-200 HP |
184 |
175 |
150 |
90 |
Head in feet at the flow in GPM heading each column: 50% and 75% of the largest curve in the block, then its end. Bold = the last column that curve reaches; — = beyond its curve. Maximum-impeller curves digitized from the Taco FI 60 Hz performance curves and rounded down. PSI = feet ÷ 2.31.
The 1511, 2510C and 5007D sizes are printed on an older curve format that could not be read reliably, or Taco publishes no 60 Hz curve for them: their curves are in the image gallery where Taco publishes one, or email your duty point and we will confirm the selection with Taco.
Before You Buy — The Limits That Decide the Fit
| Duty point |
Pick the size whose curve passes through your flow and head; send it to us and we will confirm the impeller trim with Taco before you order |
| Liquid |
Water or other suitable HVAC media; not for hazardous, corrosive or flammable liquids |
| Mounting |
On a concrete pad about 6 in longer and 6 in wider than the base and at least 6 in high, leveled and grouted |
| Priming |
Fill and vent the pump before starting; never run it dry |
| Pressure |
175 psig with Class 125 flanges; order Class 250 flanges for up to 300 psig |
| Power |
Motor and drive voltage set at order; size the supply and protection to the drive |
Installation Notes
- Pour the foundation pad about 6 in longer and 6 in wider than the base and at least 6 in high, with an anchor bolt hole at each corner
- Level the base with shims and check that the suction and discharge flanges are level
- Recheck pump-to-motor alignment after leveling, after piping and after the first few weeks of operation; it is aligned at the factory but can shift
- On closed heating systems, put the expansion tank on the suction side of the pump
- Lift by the motor frame, never by the pump casing or flanges
From the Taco FI Base Mounted Pumps Installation and Operation Instructions 302-012.
Applications
Constant flow chiller and boiler pumping and secondary variable flow pumping in HVAC systems.
Materials of Construction
| Part |
Bronze-fitted (standard) |
NSF 61 build |
| Casing |
Cast iron ASTM A48 Class 30A (125#); ductile iron ASTM A536 65-45-12 (250#) |
Same as standard |
| Cover |
Cast iron ASTM A48 Class 30A |
Cast iron ASTM A48 Class 30A |
| Impeller |
Bronze ASTM B584 C83600 or C84400 |
Stainless steel ASTM A351 |
| Shaft |
Stainless steel Type 416 ASTM A582 |
Stainless steel Type 416 ASTM A582 |
| Shaft sleeve |
Bronze ASTM B584 C92200 |
Bronze ASTM B584 C92200 |
| Mechanical seal |
Ceramic / EPT |
Ceramic / EPT |
Options: bronze wear ring, Type 303 stainless sleeve, tungsten carbide or silicon carbide seal faces. From the Taco FI submittal data sheets.