Taco KV Vertical In-Line Pump - Close-Coupled, Bronze-Fitted

HP - Speed: 1 HP - 1160 RPM
Suction x Discharge: 1-1/2 x 1-1/2 in
Model: KV1507D

Product variant with selected options does not exist!

Price
$8,419.16
Coupon 5% off applied automatically in your cart. No code needed.
SKU: KV1507D-1160-1HP
Weight : 133.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Taco · Vertical In-Line Pump, Close-Coupled
KV Series
201 US builds: 22 pump sizes, 1-60 HP, 1-1/2 to 8 in flanges, 1160 to 3500 RPM, 60 Hz.
1-60 HP Close-Coupled
1160, 1760 or 3500 RPM, 60 Hz
1-1/2 to 8 in Flanges
175 psig Std, 300 psig with 250# Flanges
250°F Max Liquid
Bronze-Fitted, NSF 61 Option
DOE PEI 0.79-0.96
15-33.5 x 6.6-19.2 x 20.4-40.8 in
132-1274 lb Weight
Overview

The KV is Taco’s close-coupled vertical in-line pump for HVAC and industrial service. The pump mounts straight in the pipe line, needs no isolation pads, and the close-coupled design keeps the pump and its standard NEMA JM motor in alignment for longer seal life. Service is from the back: the motor, cover and impeller pull out without disconnecting the pump from the piping. Each build on this listing is one pump size at one speed with one motor HP; Taco trims the impeller to your duty point when the pump is ordered.

  • Standard bronze-fitted construction, with an NSF 61 build that uses a stainless steel impeller
  • Pressure taps on suction and discharge for checking pump performance
  • Standard seal design that takes a range of seal options
  • Optional ductile iron support stand, replaceable casing wear ring and 250# flanges
What Ships and What It Needs to Run

Included: the KV pump and its NEMA JM-frame motor, close-coupled and assembled.

Set when you order: the impeller diameter for your duty point, motor voltage, and motor enclosure (ODP or TEFC).

Support stand: optional ductile iron stand, ordered with the pump where the installation calls for it.

Ships by freight: about 132-1274 lb by build; plan for a lift at delivery.

Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty

Covered for 1 year from start-up or 18 months from shipment, whichever comes first, under Taco’s limited warranty for commercial pumps. Taco states that the motor is warranted by the motor manufacturer and that seals are not covered.

Specifications
Pump type Single-stage vertical in-line volute pump, close-coupled, back pull-out
Motor NEMA standard JM-frame motor, ODP or TEFC
Speed 1160, 1760 or 3500 RPM by build, 60 Hz
Connections ANSI Class 125 flanges (standard) or Class 250, 1-1/2 to 8 in
Maximum working pressure 175 psig with Class 125 flanges; 300 psig with Class 250 flanges
Maximum liquid temperature 250°F
Mechanical seal John Crane Type 21 for 175 psig; Type 2 for 300 psig
Pump energy index DOE PEI 0.79-0.96 by build

From the Taco submittal data sheets, catalog and IOM.

Models & Performance — Will It Do What You Need?

Each block is one flange size at one speed. Every row is one pump size this listing sells, with the motor HP range Taco offers for it, and every figure is the total head in feet the pump adds at the flow heading the column, on the largest impeller Taco offers for that size. Taco trims the impeller to the duty point you order, which brings the curve down to it; the full family of impeller curves for each size is in the image gallery.

KV 1-1/2 x 1-1/2 in, 1160 RPM: 1507D, 1-1 1/2 HP, 26 ft shut-off, 94 GPM
Model, motor 0 GPM 45 70 94 (Max)
1507D, 1 HP 26 23 20 14
KV 1-1/2 x 1-1/2 in, 1760 RPM: 1506D, 1507D, 1-5 HP, 44-58 ft shut-off, 141 GPM
Model, motor 0 GPM 70 105 141 (Max)
1506D, 1-1 1/2 HP 44 38 22 —
1507D, 1-2 HP 58 53 46 34
KV 1-1/2 x 1-1/2 in, 3500 RPM: 1506D, 1507D, 3-15 HP, 174-230 ft shut-off, 255 GPM
Model, motor 0 GPM 130 190 255 (Max)
1506D, 3-10 HP 174 156 115 —
1507D, 5-15 HP 230 215 190 147
KV 2 x 2 in, 1160 RPM: 2007D, 2009D, 1-2 HP, 25-44 ft shut-off, 189 GPM
Model, motor 0 GPM 95 140 189 (Max)
2007D, 1 HP 25 20 11 —
2009D, 1-2 HP 44 40 32 15
KV 2 x 2 in, 1760 RPM: 2006D, 2007D, 2009D, 1-10 HP, 42-100 ft shut-off, 247 GPM
Model, motor 0 GPM 125 185 247 (Max)
2006D, 1-2 HP 42 31 — —
2007D, 1-3 HP 57 49 35 —
2009D, 2-7 1/2 HP 100 93 82 58
KV 2 x 2 in, 3500 RPM: 2006D, 2007D, 2009D, 3-50 HP, 164-389 ft shut-off, 419 GPM
Model, motor 0 GPM 210 315 419 (Max)
2006D, 3-15 HP 164 135 — —
2007D, 7 1/2-15 HP 222 204 167 —
2009D, 15-50 HP 389 371 340 280
KV 3 x 3 in, 1160 RPM: 3007D, 3009D, 3011D, 3013D, 1-10 HP, 23-92 ft shut-off, 377 GPM
Model, motor 0 GPM 190 285 377 (Max)
3007D, 1-1 1/2 HP 23 18 — —
3009D, 1-3 HP 43 36 20 —
3011D, 1 1/2-5 HP 55 47 25 —
3013D, 3-10 HP 92 89 79 55
KV 3 x 3 in, 1760 RPM: 3006D, 3007D, 3009D, 3011D, 3013D, 1-30 HP, 40-203 ft shut-off, 583 GPM
Model, motor 0 GPM 290 440 583 (Max)
3006D, 1-2 HP 40 — — —
3007D, 2-5 HP 54 41 — —
3009D, 3-10 HP 97 82 42 —
3011D, 5-15 HP 129 108 55 —
3013D, 7 1/2-30 HP 203 196 173 116
KV 3 x 3 in, 3500 RPM: 3006D, 3007D, 3009D, 5-60 HP, 155-374 ft shut-off, 900 GPM
Model, motor 0 GPM 450 680 900 (Max)
3006D, 5-15 HP 155 78 — —
3007D, 15-40 HP 212 190 130 —
3009D, 25-60 HP 374 345 268 106
KV 4 x 4 in, 1160 RPM: 4007D, 4009D, 4011D, 4013D, 1-15 HP, 24-84 ft shut-off, 661 GPM
Model, motor 0 GPM 330 495 661 (Max)
4007D, 1-2 HP 24 13 — —
4009D, 1 1/2-5 HP 41 34 21 —
4011D, 3-7 1/2 HP 56 47 31 —
4013D, 3-15 HP 84 75 61 33
KV 4 x 4 in, 1760 RPM: 4007D, 4009D, 4011D, 4013D, 2-40 HP, 54-193 ft shut-off, 921 GPM
Model, motor 0 GPM 460 690 921 (Max)
4007D, 2-7 1/2 HP 54 34 — —
4009D, 5-15 HP 92 80 57 —
4011D, 7 1/2-25 HP 127 110 81 —
4013D, 15-40 HP 193 176 151 98
KV 4 x 4 in, 3500 RPM: 4007D, 4009D, 15-60 HP, 208-355 ft shut-off, 1,570 GPM
Model, motor 0 GPM 790 1,180 1,570 (Max)
4007D, 15-40 HP 208 158 — —
4009D, 40-60 HP 355 325 265 154
KV 5 x 5 in, 1160 RPM: 5007D, 1-3 HP, 24 ft shut-off, 535 GPM
Model, motor 0 GPM 270 400 535 (Max)
5007D, 1-3 HP 24 21 16 8
KV 5 x 5 in, 1760 RPM: 5007D, 3-7 1/2 HP, 54 ft shut-off, 802 GPM
Model, motor 0 GPM 400 600 802 (Max)
5007D, 3-7 1/2 HP 54 46 37 19
KV 5 x 5 in, 3500 RPM: 5007D, 25-60 HP, 209 ft shut-off, 1,504 GPM
Model, motor 0 GPM 750 1,130 1,504 (Max)
5007D, 25-60 HP 209 183 149 85
KV 6 x 6 in, 1160 RPM: 6007D, 6009D, 6011D, 6013D, 1 1/2-25 HP, 21-84 ft shut-off, 1,349 GPM
Model, motor 0 GPM 670 1,010 1,349 (Max)
6007D, 1 1/2-3 HP 21 9 — —
6009D, 3-7 1/2 HP 37 31 18 —
6011D, 5-10 HP 53 45 26 —
6013D, 7 1/2-25 HP 84 75 58 29
KV 6 x 6 in, 1760 RPM: 6007D, 6009D, 6011D, 6013D, 5-50 HP, 46-191 ft shut-off, 1,960 GPM
Model, motor 0 GPM 980 1,470 1,960 (Max)
6007D, 5-10 HP 46 23 — —
6009D, 7 1/2-25 HP 85 73 46 —
6011D, 15-40 HP 121 104 66 —
6013D, 25-50 HP 191 173 141 73
KV 6 x 6 in, 3500 RPM: 6007D, 30-60 HP, 192 ft shut-off, 2,252 GPM
Model, motor 0 GPM 1,130 1,690 2,252 (Max)
6007D, 30-60 HP 192 176 131 27
KV 8 x 8 in, 1160 RPM: 8011D, 7 1/2-20 HP, 54 ft shut-off, 1,779 GPM
Model, motor 0 GPM 890 1,330 1,779 (Max)
8011D, 7 1/2-20 HP 54 48 38 18
KV 8 x 8 in, 1760 RPM: 8011D, 20-50 HP, 124 ft shut-off, 2,744 GPM
Model, motor 0 GPM 1,370 2,050 2,744 (Max)
8011D, 20-50 HP 124 109 85 37

Head in feet at the flow in GPM heading each column: 50% and 75% of the largest curve in the block, then its end. Bold = the last column that curve reaches; — = beyond its curve. Maximum-impeller curves digitized from the Taco KV 60 Hz performance curves and rounded down. PSI = feet ÷ 2.31.

The 1509 and 2011 sizes are printed on an older curve format that could not be read reliably, or Taco publishes no 60 Hz curve for them: their curves are in the image gallery where Taco publishes one, or email your duty point and we will confirm the selection with Taco.

Before You Buy — The Limits That Decide the Fit
Duty point Pick the size whose curve passes through your flow and head; send it to us and we will confirm the impeller trim with Taco before you order
Liquid Water or other suitable HVAC media; not for hazardous, corrosive or flammable liquids
Mounting Vertical, motor up; consult Taco for horizontal mounting. The pump must always be supported
Priming Fill and vent the pump before starting; never run it dry
Pressure 175 psig with Class 125 flanges; order Class 250 flanges for up to 300 psig
Installation Notes
  • Pumps with smaller motors may hang in the piping when the pipe is supported next to the pump; larger motors need a support under the casing, using the tapped holes in its base
  • Keep piping loads off the pump and let it move with the piping; do not rigidly fix it to the floor, and use vibration isolation pads under floor supports
  • Lift by the motor eye bolts together with the pump adapter, and never cover any part of the motor with insulation
  • Jog the motor to check rotation, open the suction valve, start against a closed discharge valve and open it slowly
  • Do not run for long periods against a closed discharge valve

From the Taco KV Installation, Operation and Maintenance Manual 302-031.

Applications

HVAC heating and cooling circulation and industrial applications.

Materials of Construction
Part Bronze-fitted (standard) NSF 61 build
Casing Cast iron ASTM A48 Class 30A (125#); ductile iron ASTM A536 65-45-12 (250#) Same as standard
Cover Cast iron ASTM A48 Class 30A Cast iron ASTM A48 Class 30A
Impeller Bronze ASTM B584 C83600 or C84400 Stainless steel ASTM A351
Shaft Carbon steel Carbon steel
Shaft sleeve Bronze ASTM B584 C92200 Bronze ASTM B584 C92200
Mechanical seal Ceramic / EPT Ceramic / EPT

Options: bronze wear ring, Type 303 stainless sleeve, tungsten carbide or silicon carbide seal faces. From the Taco KV submittal data sheets.

For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.