Taco CI End Suction Pump - Close-Coupled, Bronze-Fitted

HP - Speed: 1 HP - 1160 RPM
Suction x Discharge: 2 x 1-1/4 in
Model: CI1207D

Product variant with selected options does not exist!

Price
$7,719.95
Coupon 5% off applied automatically in your cart. No code needed.
SKU: CI1207D-1160-1HP
Weight : 118.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Taco · End Suction Pump, Close-Coupled
CI Series
224 US builds: 28 pump sizes, 1-60 HP, 1-1/2 to 8 in flanges, 1160 to 3500 RPM, 60 Hz.
1-60 HP Close-Coupled
1160, 1760 or 3500 RPM, 60 Hz
1-1/2 to 8 in Flanges
175 psig Std, 300 psig with 250# Flanges
250°F Max Liquid
Bronze-Fitted, NSF 61 Option
DOE PEI 0.78-0.97
19.1-35.1 L x 8.7-20.4 H in
118-1055 lb Weight
Overview

The CI is Taco’s close-coupled end suction pump for heating, air conditioning, pressure boosting, cooling water transfer and water supply. The pump mounts on the motor, so there is no base plate or pump-to-motor alignment, and the rear pull-out design lets the pump be serviced without disturbing the system piping. A slip-on shaft sleeve and flush seal line taps make seal maintenance easier in the field. Each build on this listing is one pump size at one speed with one motor HP; Taco trims the impeller to your duty point when the pump is ordered.

  • Standard ceramic seal that suits a wide range of applications
  • Flush seal line taps for fitting a filter to protect the seal
  • Centerline discharge for positive air venting, with gauge ports on suction and discharge
  • Bronze-fitted standard; NSF 61 build with stainless steel impeller available
What Ships and What It Needs to Run

Included: the CI pump and its NEMA JM-frame motor, close-coupled and assembled.

Set when you order: the impeller diameter for your duty point, motor voltage, and motor enclosure (ODP or TEFC).

Ships by freight: about 118-1055 lb by build; plan for a lift at delivery.

Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty

Covered for 1 year from start-up or 18 months from shipment, whichever comes first, under Taco’s limited warranty for commercial pumps. Taco states that the motor is warranted by the motor manufacturer and that seals are not covered.

Specifications
Pump type Single-stage end suction volute pump, close-coupled, rear pull-out
Motor NEMA standard JM-frame motor, ODP or TEFC
Speed 1160, 1760 or 3500 RPM by build, 60 Hz
Connections ANSI Class 125 flanges (standard) or Class 250, 1-1/2 to 8 in
Maximum working pressure 175 psig with Class 125 flanges; 300 psig with Class 250 flanges
Maximum liquid temperature 250°F
Mechanical seal Mechanical seal, ceramic / EPT standard
Pump energy index DOE PEI 0.78-0.97 by build

From the Taco submittal data sheets, catalog and IOM.

Models & Performance — Will It Do What You Need?

Each block is one flange size at one speed. Every row is one pump size this listing sells, with the motor HP range Taco offers for it, and every figure is the total head in feet the pump adds at the flow heading the column, on the largest impeller Taco offers for that size. Taco trims the impeller to the duty point you order, which brings the curve down to it; the full family of impeller curves for each size is in the image gallery.

CI 2 x 1-1/4 in, 1160 RPM: 1207D, 1-1 HP, 25 ft shut-off, 99 GPM
Model, motor 0 GPM 50 75 99 (Max)
1207D, 1 HP 25 23 21 16
CI 2 x 1-1/4 in, 1760 RPM: 1206D, 1207D, 1-2 HP, 40-58 ft shut-off, 134 GPM
Model, motor 0 GPM 65 100 134 (Max)
1206D, 1-1 1/2 HP 40 36 25 —
1207D, 1-2 HP 58 54 48 37
CI 2 x 1-1/4 in, 3500 RPM: 1206D, 1207D, 3-10 HP, 161-230 ft shut-off, 215 GPM
Model, motor 0 GPM 110 160 215 (Max)
1206D, 3-7 1/2 HP 161 149 129 —
1207D, 5-10 HP 230 221 206 180
CI 2-1/2 x 1-1/2 in, 1160 RPM: 1507D, 1509D, 2007D, 2009D, 1-3 HP, 24-44 ft shut-off, 233 GPM
Model, motor 0 GPM 115 175 233 (Max)
1507D, 1 HP 24 18 — —
1509D, 1-2 HP 44 36 — —
2007D, 1 HP 24 20 11 —
2009D, 1-3 HP 42 39 32 17
CI 2-1/2 x 2-1/2 in, 1760 RPM: 1506D, 1507D, 1509D, 2007D, 2009D, 1-10 HP, 41-101 ft shut-off, 347 GPM
Model, motor 0 GPM 175 260 347 (Max)
1506D, 1-2 HP 41 — — —
1507D, 1-3 HP 57 38 — —
1509D, 2-7 1/2 HP 101 80 — —
2007D, 1-3 HP 54 45 27 —
2009D, 2-7 1/2 HP 97 88 73 38
CI 2-1/2 x 2-1/2 in, 3500 RPM: 1506D, 1507D, 1509D, 2007D, 2009D, 3-40 HP, 159-399 ft shut-off, 582 GPM
Model, motor 0 GPM 290 435 582 (Max)
1506D, 3-10 HP 159 102 — —
1507D, 7 1/2-15 HP 226 176 — —
1509D, 15-25 HP 399 343 — —
2007D, 7 1/2-15 HP 212 188 141 —
2009D, 20-40 HP 379 361 319 245
CI 3 x 2-1/2 in, 1160 RPM: 2507D, 2509D, 2511D, 2513D, 1-10 HP, 22-82 ft shut-off, 375 GPM
Model, motor 0 GPM 190 280 375 (Max)
2507D, 1-1 1/2 HP 22 18 9 —
2509D, 1-3 HP 42 35 25 —
2511D, 1 1/2-5 HP 57 47 29 —
2513D, 3-10 HP 82 77 64 33
CI 3 x 2-1/2 in, 1760 RPM: 2506D, 2507D, 2509D, 2511D, 2513D, 1-25 HP, 40-189 ft shut-off, 470 GPM
Model, motor 0 GPM 235 355 470 (Max)
2506D, 1-2 HP 40 16 — —
2507D, 2-5 HP 51 46 34 —
2509D, 3-10 HP 95 87 71 —
2511D, 5-15 HP 132 117 92 —
2513D, 10-25 HP 189 183 166 132
CI 3 x 2-1/2 in, 3500 RPM: 2506D, 2507D, 2509D, 5-40 HP, 157-375 ft shut-off, 904 GPM
Model, motor 0 GPM 450 680 904 (Max)
2506D, 5-10 HP 157 67 — —
2507D, 15-25 HP 205 189 148 —
2509D, 25-40 HP 375 349 290 187
CI 4 x 3 in, 1160 RPM: 3007D, 3009D, 3011D, 3013D, 1-10 HP, 23-84 ft shut-off, 636 GPM
Model, motor 0 GPM 320 475 636 (Max)
3007D, 1-2 HP 23 14 — —
3009D, 1 1/2-5 HP 40 34 23 —
3011D, 3-7 1/2 HP 55 47 34 —
3013D, 3-10 HP 84 76 62 28
CI 4 x 3 in, 1760 RPM: 3007D, 3009D, 3011D, 3013D, 2-30 HP, 51-194 ft shut-off, 921 GPM
Model, motor 0 GPM 460 690 921 (Max)
3007D, 2-7 1/2 HP 51 33 — —
3009D, 5-15 HP 93 79 56 —
3011D, 7 1/2-15 HP 126 111 84 —
3013D, 15-30 HP 194 178 147 79
CI 4 x 3 in, 3500 RPM: 3007D, 3009D, 15-60 HP, 203-362 ft shut-off, 1,438 GPM
Model, motor 0 GPM 720 1,080 1,438 (Max)
3007D, 15-25 HP 203 167 84 —
3009D, 40-60 HP 362 335 282 194
CI 5 x 4 in, 1160 RPM: 4007D, 4009D, 4013D, 1-15 HP, 21-84 ft shut-off, 887 GPM
Model, motor 0 GPM 445 670 887 (Max)
4007D, 1-3 HP 21 15 — —
4009D, 2-5 HP 38 33 22 —
4013D, 5-15 HP 84 79 68 51
CI 5 x 4 in, 1760 RPM: 4007D, 4009D, 4011C, 4013D, 3-40 HP, 48-193 ft shut-off, 1,326 GPM
Model, motor 0 GPM 660 1,000 1,326 (Max)
4007D, 3-7 1/2 HP 48 34 — —
4009D, 7 1/2-15 HP 87 77 52 —
4011C, 10-25 HP 130 115 75 —
4013D, 20-40 HP 193 182 158 122
CI 5 x 4 in, 3500 RPM: 4007D, 25-40 HP, 189 ft shut-off, 1,581 GPM
Model, motor 0 GPM 790 1,190 1,581 (Max)
4007D, 25-40 HP 189 179 145 80
CI 6 x 5 in, 1160 RPM: 5007D, 5009D, 5011D, 1 1/2-10 HP, 20-51 ft shut-off, 1,164 GPM
Model, motor 0 GPM 580 870 1,164 (Max)
5007D, 1 1/2-3 HP 20 14 — —
5009D, 3-7 1/2 HP 36 33 26 —
5011D, 5-10 HP 51 47 35 13
CI 6 x 5 in, 1760 RPM: 5009D, 5011D, 5-30 HP, 82-116 ft shut-off, 1,783 GPM
Model, motor 0 GPM 890 1,340 1,783 (Max)
5009D, 7 1/2-20 HP 82 75 55 —
5011D, 15-30 HP 116 106 78 26
CI 8 x 6 in, 1160 RPM: 6009D, 6011D, 5-20 HP, 36-52 ft shut-off, 1,674 GPM
Model, motor 0 GPM 840 1,260 1,674 (Max)
6009D, 5-15 HP 36 34 27 —
6011D, 7 1/2-20 HP 52 50 43 29
CI 8 x 6 in, 1760 RPM: 6009D, 6011D, 20-50 HP, 82-116 ft shut-off, 2,497 GPM
Model, motor 0 GPM 1,250 1,870 2,497 (Max)
6009D, 20-40 HP 82 80 65 —
6011D, 20-50 HP 116 113 97 67

Head in feet at the flow in GPM heading each column: 50% and 75% of the largest curve in the block, then its end. Bold = the last column that curve reaches; — = beyond its curve. Maximum-impeller curves digitized from the Taco CI 60 Hz performance curves and rounded down. PSI = feet ÷ 2.31.

The 1209C, 1511B, 2510C, 4011C and 5007D sizes are printed on an older curve format that could not be read reliably, or Taco publishes no 60 Hz curve for them: their curves are in the image gallery where Taco publishes one, or email your duty point and we will confirm the selection with Taco.

Before You Buy — The Limits That Decide the Fit
Duty point Pick the size whose curve passes through your flow and head; send it to us and we will confirm the impeller trim with Taco before you order
Liquid Water or other suitable HVAC media; not for hazardous, corrosive or flammable liquids
Mounting On a solid foundation; Taco recommends a concrete block about 4 in longer and 4 in wider than the pump base
Priming Fill and vent the pump before starting; never run it dry
Pressure 175 psig with Class 125 flanges; order Class 250 flanges for up to 300 psig
Installation Notes
  • Set the pump on a concrete block about 4 in longer and 4 in wider than its base
  • Make the pipe flanges line up squarely with the pump flanges; never pull piping into place at the pump
  • On closed heating systems, put the expansion tank on the suction side of the pump
  • Keep the suction pipe short and straight on open systems
  • Start against a closed discharge valve and open it slowly

From the Taco CI Close Coupled Pumps Installation and Operation Instructions 302-003A.

Applications

Heating, air conditioning, pressure boosting, cooling water transfer and water supply.

Materials of Construction
Part Bronze-fitted (standard) NSF 61 build
Casing Cast iron ASTM A48 Class 30A (125#); ductile iron ASTM A536 65-45-12 (250#) Same as standard
Cover Cast iron ASTM A48 Class 30A Cast iron ASTM A48 Class 30A
Impeller Bronze ASTM B584 C83600 or C84400 Stainless steel ASTM A351
Shaft Carbon steel Carbon steel
Shaft sleeve Bronze ASTM B584 C92200 Bronze ASTM B584 C92200
Mechanical seal Ceramic / EPT Ceramic / EPT

Options: bronze wear ring, Type 303 stainless sleeve, tungsten carbide or silicon carbide seal faces. From the Taco CI submittal data sheets.

For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.