Taco · In-Line Pump, Bearing Frame
1600 Series
28 US builds: 15 models, 1/4-3 HP, 1-1/2 and 2 in flanges, 1750 RPM, 60 Hz.
1/4-3 HP Bearing Frame
1750 RPM, 60 Hz
1-1/2 and 2 in Flanges
175 psig Working Pressure
250°F Std, 300°F Optional Seal
Stainless Steel Impeller
Up to 238 GPM, 67 ft
59-153 lb Weight
Overview
The 1600 Series is Taco’s small commercial in-line pump with a bearing frame, for heating, air conditioning, pressure boosting, cooling water transfer and water supply. A replaceable “cooler running” bearing cartridge isolates the permanently sealed ball bearings from the system fluid temperature, a flexible coupler keeps motor noise and vibration out of the piping, and the rear pull-out design lets the pump be serviced without disturbing the piping. One cartridge, one seal and two motor frames fit every model.
- One-piece enclosed, dynamically balanced 304 stainless steel impeller
- Type 21 mechanical seal, ceramic standard or Sealide C for more aggressive fluids
- 1/4 in NPT pressure tappings on suction and discharge
- Resilient-mounted NEMA motor; companion flanges included
What Ships and What It Needs to Run
Included: the 1600 pump and its resilient-mounted NEMA motor, assembled, with companion flanges.
Set when you order: motor voltage (single phase, 200V or 230/460V three phase) and, for custom models, the impeller trim for your duty point; 1/4 and 1/3 HP motors are single phase only.
Ships: about 59-153 lb by build.
Genuine Taco equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Taco Distributor.
1-Year Taco Warranty
Covered for 1 year from the date code under Taco’s limited warranty for commercial pumps. Taco states that seals on commercial pumps are not covered.
Specifications
| Pump type |
Single-stage in-line pump, bearing frame with flexible coupler, rear pull-out |
| Motor |
NEMA standard, resilient mounted; 1750 RPM, 60 Hz |
| Connections |
Flanged in-line, 1-1/2 or 2 in; companion flanges included |
| Maximum working pressure |
175 psig (125 psi flanges standard) |
| Maximum liquid temperature |
250°F with the standard seal; 300°F with the high-temperature seal |
| Mechanical seal |
Type 21, carbon / ceramic with EPT elastomers; Sealide C optional |
| Bearings |
Permanently lubricated ball bearings in a replaceable cartridge |
From the Taco submittal data sheets, catalog and instruction sheets.
Models & Performance — Will It Do What You Need?
Each row is one pump model this listing sells, with the motor HP Taco offers for it. Stock models (1600, 1610, 1612, 1614, 1616 and 1630 to 1638) come with one fixed impeller and motor; custom models (1611, 1615, 1619, 1635, 1641) are trimmed by Taco to your duty point, and their figures are on the largest impeller. Every figure is the total head in feet the pump adds at the flow heading the column; the last column is where the curve ends, as GPM @ ft.
1600 Series 1-1/2 in, 1750 RPM: 1600 to 1615, 1/4-1 HP, 20-43 ft shut-off, up to 81 GPM
| Model, motor |
0 GPM |
40 GPM |
60 GPM |
Curve end (GPM @ ft) |
| 1600, 1/4 HP |
20 |
16 |
10 |
76 @ 3 |
| 1610, 1/3 HP |
24 |
20 |
14 |
81 @ 5 |
| 1611, 1/4-1/2 HP |
24 |
20 |
14 |
81 @ 5 |
| 1612, 1/2 HP |
35 |
29 |
21 |
69 @ 5 |
| 1614, 3/4 HP |
43 |
38 |
30 |
79 @ 7 |
| 1615, 1/3-1 HP |
43 |
38 |
30 |
79 @ 7 |
1600 Series 2 in, 1750 RPM: 1616 to 1641, 1/2-3 HP, 22-67 ft shut-off, up to 238 GPM
| Model, motor |
0 GPM |
100 GPM |
150 GPM |
Curve end (GPM @ ft) |
| 1616, 1 HP |
51 |
— |
— |
80 @ 24 |
| 1619, 3/4-2 HP |
67 |
30 |
— |
100 @ 30 |
| 1630, 1/2 HP |
22 |
12 |
— |
120 @ 7 |
| 1632, 3/4 HP |
30 |
21 |
— |
145 @ 10 |
| 1634, 1 HP |
38 |
30 |
18 |
167 @ 12 |
| 1635, 1/2-1 1/2 HP |
38 |
30 |
18 |
167 @ 12 |
| 1636, 1 1/2 HP |
40 |
37 |
27 |
183 @ 15 |
| 1638, 2 HP |
48 |
44 |
34 |
200 @ 18 |
| 1641, 1 1/2-3 HP |
65 |
61 |
53 |
238 @ 25 |
Read from the Taco 1600 Series 1750 RPM performance curves (the scanned originals are in the image gallery) and rounded down; confirm your duty point with us before you order. — = beyond the end of that curve. PSI = feet ÷ 2.31.
Before You Buy — The Limits That Decide the Fit
| Duty point |
Pick the model whose row covers your flow and head; send it to us and we will confirm the selection with Taco |
| Liquid |
Water or water/glycol HVAC media; not for hazardous or flammable liquids |
| Temperature |
250°F with the standard seal; order the high-temperature seal for up to 300°F |
| Pressure |
175 psig working pressure |
| Power |
1/4 and 1/3 HP motors are single phase only |
Installation Notes
- Support the piping close to the pump so its weight does not hang on the pump body
- Fill and vent the system before starting; never run the pump dry
- Check that the motor rotation matches the arrow on the pump body
- Leave room behind the motor for rear pull-out service of the bearing cartridge and seal
From the Taco 1600 Series In-Line Pumps Instruction Sheet 302-001.
Applications
LoadMatch systems, air conditioning, heating systems, recirculation, booster service, cooling towers, golf courses, livestock watering, laundry equipment and lawn sprinklers.
Materials of Construction
| Part |
Standard |
| Casing |
Cast iron (304 stainless steel optional) |
| Impeller |
Cast 304 stainless steel |
| Shaft |
416 stainless steel |
| Bracket |
Cast iron (with stainless steel face plate on stainless and NSF 61 builds) |
An all-stainless NSF 61 build is available; ask us. From the Taco 1600 Series catalog 300-1.1.