Smith-Blair Style 257 Repair Clamp - Stainless, Double Band, 4.74-14.45 in OD

Pipe OD Range: 4.74-5.54 in OD
Width - Part No.: 7.5 in - 257-00048007-000

Product variant with selected options does not exist!

Price
$886.35
SKU: 257-00048007-000
Weight : 15.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Smith-Blair · Repair Clamp
Style 257 Full Circle Repair Clamp
All Stainless Steel, Cast Lugs, Double Band
200 PSI Max Working Pressure
-20°F to +180°F Temperature
Nitrile (Buna-N) Gasket
All 304 Stainless Steel
Cast Stainless Lugs
NSF/ANSI 61 and 372
4.74-14.45 in Pipe OD
15-73 lb Weight
Description

The Smith-Blair Style 257 is the double-band, all-stainless Full Circle repair clamp for hot soils and other corrosive environments. A 360° Nitrile gasket gives complete leak repair, cast stainless lugs and stainless bolts leave no welded parts, and the lugs remove for installation in tight places.

Application: hot soils and other corrosive environments, on cast iron, ductile iron, asbestos cement, PVC, HDPE, steel, copper, fiberglass and other pipe types.

Key Features

  • Working pressure up to 200 PSI
  • All stainless with no welded parts — built for hot soils
  • Up to 0.80 in of OD range in the double band
  • Widths 7.5, 15 and 22.5 in; removable lugs and drop-in bolts
  • Certified to NSF/ANSI 61 and NSF/ANSI 372
What Ships and What It Needs to Run

Included: the clamp with its Nitrile gasket, lugs, bolts and nuts, ready to install.

Belleville spring washers on HDPE pipe, ordered separately. Smith-Blair p/n 150115-000 washers are required on HDPE pipe (not for gas service); ask us to include them with the clamp.

Genuine Smith-Blair equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
12-Month Smith-Blair Warranty

Smith-Blair warrants its products to be free of defects in materials and workmanship for one year from the date of shipment by Smith-Blair. Dated proof of purchase, such as a bill of sale, is required to establish eligibility. Smith-Blair will repair or, at its option, replace a defective product; the product is returned to the factory or warehouse Smith-Blair designates.

Working Pressure

Up to 200 PSI. Smith-Blair rates the allowable working pressure of a repair clamp to fall as pipe diameter rises; for a particular installation it is set by pipe size and type, the type and extent of the damage, service conditions and installation workmanship.

Materials Specifications
Band Type 304 stainless steel
Lugs CF8 austenitic cast stainless steel (304 equivalent)
Gasket Nitrile (Buna-N), resists water, acids, alkalies, most aliphatic hydrocarbons and other chemicals
Bridge plate Type 304 stainless steel, recessed flush and bonded to the gasket
Bolts Type 304 stainless steel with rolled threads, fluoropolymer coated to prevent galling
Temperature range -20°F to +180°F

Materials subject to change by the manufacturer.

Pipe Applications

Cast iron, ductile iron, asbestos cement, PVC, HDPE (with spring washers), steel, copper, fiberglass and other pipe types.

Sizes
Pipe size and OD Widths
4.74-5.54 in 7.5, 15, 22.5 in
6.84-7.64 in 7.5, 15, 22.5 in
8.99-9.79 in 7.5, 15, 22.5 in
11.04-11.84 in 7.5, 15, 22.5 in
11.60-12.40 in 7.5, 15, 22.5 in
13.14-13.94 in 7.5, 15, 22.5 in
13.65-14.45 in 7.5, 15, 22.5 in

Choose the pipe OD in the first row above; the part number shows in the second row.

Installation Notes
  • Clean the pipe where the clamp will sit, removing scale, dirt and debris that could spoil the gasket seal.
  • Lubricate the pipe and gasket with a soap-and-water solution that meets the water and pipe supplier’s requirements.
  • Where the pipe ends gap 1 in or more, bridge the gap with a short section of pipe or a thin strip of sheet metal to support the gasket.
  • Where 40% or more of the circumference is broken away, cover the opening with sheet metal and use a clamp that extends 3 in past it on both sides.
  • Engage the centermost bolts first and tighten from the center outward, keeping the clamp centered on the break; finish with a calibrated torque wrench to the torque in the instructions.
  • Anchor the pipe: the clamp seals around it, and Smith-Blair requires proper anchoring to restrain pipe movement and prevent pull-out.

From Smith-Blair Installation Instructions TI-002 (Rev 08/26/21), in the Data Sheet tab.

Before You OrderAll Smith-Blair products are Made to Order and Non-Returnable.
Items typically shipped in 5 - 10 business days.
Odd pipe ODs, other widths and other materials are built to order — email sales@watermainsupply.com with the pipe OD and material.
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

You May Also Like