Pick the boost and the system flow you need, then the horsepower and your supply. The quadplex runs 4 pumps in parallel, so the system holds each pump’s boost and the flow adds up across the pumps. Max boost is the pressure a pump adds at zero flow; max flow is the system’s: the end of the pump’s curve times 4. The model number reads V4-{max GPM}-{max boost}-{voltage code}: 323 = 208-230V 3Ph, 348 = 480V 3Ph. Each build is listed on one Ebara vertical multistage pump per horsepower, in the table below.
Pump by horsepower — the Ebara pump each build is listed on, and where its curve is in the product images.
| HP per pump |
Pump |
Curve |
| 2 HP |
Ebara EVMSU5 4 |
Image 2 |
| 3 HP |
Ebara EVMSU10 3 |
Image 3 |
| 5 HP |
Ebara EVMSU20 2 |
Image 4 |
| 7 1/2 HP |
Ebara EVMU32 2-2 |
Image 5 |
| 10 HP |
Ebara EVMU32 3-2 |
Image 5 |
| 15 HP |
Ebara EVMU45 2-1 |
Image 6 |
| 20 HP |
Ebara EVMU64 2-1 |
Image 7 |
Pressure added in PSI, quadplex system — 2 to 5 HP (tables end at 169, 317 and 528 GPM)
| Build |
0 GPM (Shut-off) |
126 GPM |
169 GPM |
264 GPM |
317 GPM |
528 GPM |
| 4 x Ebara EVMSU5 4 · 2 HP |
78 |
57.5 |
41.6 |
— |
— |
— |
| 4 x Ebara EVMSU10 3 · 3 HP |
68.1 |
65.3 |
61.5 |
45 |
31.5 |
— |
| 4 x Ebara EVMSU20 2 · 5 HP |
70.3 |
66 |
64.6 |
62.5 |
60.3 |
46.6 |
Pressure added in PSI, quadplex system — 7 1/2 to 20 HP (curves end at 739, 1,108 and 1,584 GPM)
| Build |
0 GPM (Shut-off) |
360 GPM |
739 GPM |
1,108 GPM |
1,360 GPM |
1,584 GPM |
| 4 x Ebara EVMU32 2-2 · 7 1/2 HP |
76 |
66 |
34 |
— |
— |
— |
| 4 x Ebara EVMU32 3-2 · 10 HP |
120 |
106 |
61 |
— |
— |
— |
| 4 x Ebara EVMU45 2-1 · 15 HP |
97 |
90 |
82 |
59 |
— |
— |
| 4 x Ebara EVMU64 2-1 · 20 HP |
105 |
102 |
98 |
90 |
80 |
68 |
Pressure added at full speed (60 Hz). Each flow is 4 times the single-pump flow: derived from the single-pump data at 4 times the flow, since Ebara and Sencillo publish no combined table for these sets. Single-pump source: 2-5 HP: Ebara’s printed EVMSU selection tables (EVMSU/EVMU 60 Hz data book, pp. 10-11), printed in feet, converted and rounded down to 0.1 PSI. 7 1/2-20 HP: digitized from Ebara’s EVMU curves (same data book, pp. 18-20) and rounded down to whole PSI. Feet = PSI × 2.31. Bold = the last point on that pump’s curve or table, the system’s max flow; — = beyond it. Zero flow is the shut-off ceiling, not a working point. Each pump’s full curve is in the product images. Sencillo confirms the pump and stages for your duty on the factory submittal before the system is built.
Drawing from a tank or cistern — nothing arrives with pressure, so the boost on the curve is the pressure you get at that flow.
Fed by a city main — the pumps add on top of the incoming pressure, and the drives hold the set point by running slower. Incoming pressure turns into extra flow at the same set point.
The price covers the packaged skid as configured: pumps and motors, a variable speed drive per pump, the UL508A panel with PLC and touch screen, valves, gauges and the stainless frame. The hydro tank is ordered separately (see the diaphragm pressure tank). Other pump counts are on their own listings; five- and six-pump systems, and pumps above 20 HP, are built to order: call or email us.