A.Y. McDonald DuraMAC Sewage Ejector Package - 1/2 HP

Basin and Lid: 18 x 30 in, Solid Lid
Alarm - Float: No Alarm - Tethered
Model: 5050CTSJPAC

Product variant with selected options does not exist!

MAP
Price
$804.09
SKU: 6192-115
Weight : 54.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
A.Y. McDonald · Sewage Pump Package
DuraMAC Sewage Ejector Packages
Pre-assembled simplex packages with a 1/2 HP cast iron sewage pump, basin, lid, check valve and stub pipe, ready to set: 30 or 45 gallon basins, with or without a tank alarm.
25 ft Max Lift · 80 GPM Max
1/2 HP 120V 1Ph
30 or 45 Gallon Basin
2 in Solids
2 in Discharge
4 in Inlet
Alarm Options
Pre-Assembled
54-65 lb Weight
What Ships and What It Needs to Run

Included: the 5050CTSJ or 5050CVSJ 1/2 HP cast iron sewage pump with float switch; a structural foam basin with 4 in inlet hub; a gasketed structural foam lid with stainless steel fasteners; a 2 in full-flow check valve with rubber boots; and a 30 in, 2 in PVC stub pipe (18 x 30 in packages). Alarm models add the tank alarm. Contents by model are in the table below.

Sized at install: discharge and vent piping beyond the stub pipe, shutoff valve, electrical.

Overview

These pre-assembled simplex sewage packages are designed for any residential sewage application. With a 30 gallon basin (45 gallons on the 24 x 24 in package), 2 in solids handling and a 2 in discharge pipe connected to the pump, each package is ready to install.

  • Split lid (PACSL) — reach the pump without disturbing the discharge pipe; inspection port included.
  • Alarm packages — automatic alarm reset, silence and test switches. The PACSDA has a side discharge and a NEMA 3R alarm; the DA1 models a top discharge and a NEMA 1 alarm.
  • Non-clogging stainless steel vortex impeller.
Genuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.
A.Y. McDonald Warranty by Model

Under Baker Manufacturing’s published limited warranty (A.Y. McDonald Pumps & Accessories price list, effective 7/1/26): 3 years from the date of installation: 5050CTSJPAC, 5050CTSJPACSDA, 5050CTSJPACSL, 5050CTSJPAC24. 1 year from the date of installation, or 2 years from the date of manufacture, whichever comes first: 5050CTSJPACDA1, 5050CVSJPACCH, 5050CVSJPACDA1. Per Baker’s terms, the warranty does not cover failure caused by sand or abrasive materials in the water.

Outgrow It and You Don’t Replace It

Simplex package. For duplex stations, ask us.

Models & Ratings (60 Hz)
Model Part No. Pump Basin Lid Alarm Cord Weight
5050CTSJPAC 6192-115 5050CTSJ, tethered 18 x 30 in, 30 gal, Snap-In-Hub Solid None 10 ft 54 lb
5050CTSJPACSDA 6192-122 5050CTSJ25, tethered 18 x 30 in, Snap-In-Hub, side discharge Solid NEMA 3R 25 ft 65 lb
5050CTSJPACDA1 6192-130 5050CTSJ, tethered 18 x 30 in, Combo Hub, top discharge Solid NEMA 1 10 ft 62 lb
5050CVSJPACCH 6192-132 5050CVSJ, vertical 18 x 30 in, Combo Hub (per model code) Solid None 10 ft 54 lb (est.)
5050CVSJPACDA1 6192-134 5050CVSJ, vertical 18 x 30 in, Combo Hub, top discharge Solid NEMA 1 10 ft 62 lb (est.)
5050CTSJPACSL 6192-120 5050CTSJ, tethered 18 x 30 in, Snap-In-Hub Split, with inspection port None 10 ft 58 lb
5050CTSJPAC24 6192-121 5050CTSJ, tethered 24 x 24 in, 45 gal Solid None 10 ft 62 lb

Source: A.Y. McDonald Pumps by Baker catalog, rev 3/26, and Pumps & Accessories price list, effective 7/1/26.

Shared Specifications
Pump 1/2 HP cast iron sewage, 120V 1 phase, 7.6 A
Solids 2 in
Discharge 2 in, full-flow check valve with rubber boots
Inlet 4 in
Performance — Will It Do What You Need?
Total head → 0 ft 5 ft 10 ft 15 ft 20 ft 25 ft
Pump in every package (5050CTSJ / CVSJ) 80 68 60 44 13 2

Gallons per minute at each total head, as printed by A.Y. McDonald. Total head is the vertical lift from the water level to the highest point of the discharge, plus pipe and fitting friction. A dash is a head the pump does not reach. Source: A.Y. McDonald Pumps by Baker catalog, rev 3/26, pp. 314 to 318. The 5050CVSJPACCH and 5050CVSJPACDA1 are vertical-switch packages from the 7/1/26 price list; contents shown are inferred from the model codes and the matching catalog packages.

Before You Buy — The Limits That Decide the Fit
Discharge velocity Codes require at least 2 ft/s in the discharge pipe: about 21 GPM in 2 in pipe. Check the table at your total head.
Basin A sealed, vented sewage basin with a gasketed lid; check local code for vent size.
Alarm A high-water alarm is good practice and required by many codes.
Check valve and shutoff Fit a check valve and a full-port shutoff on the discharge.
Power 120V single phase.
Accessories
Accessory Code Description
Lid gasket 5000LDGKT Replacement lid gasket
Side discharge gasket 5000SDGSKT 4 in side discharge gasket
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

You May Also Like