Industry-leading pump controls and monitoring equipment built around Godwin's PrimeGuard 2 microprocessor controller, Field Smart Technology (FST) cellular/satellite remote monitoring, and a full range of industrial control panels for electric-drive pumps including VFD up to 400 HP.

Pump controls determine operating cost, reliability, and operator-attention burden. Godwin's control offering is engineered to make unattended operation safe and reliable.
Fully programmable engine control system. Inputs from level transducers, pressure switches, or floats. Auto start/stop with no operator intervention.
Cellular or satellite remote monitoring. Engine and pump data collected at 1-minute intervals. View status, run hours, fuel, faults from anywhere.
Industrial-grade manual or automatic control panels for electric pumps. NEMA 3R enclosures for outdoor installation.
Variable Frequency Drive panels for variable-speed pump operation. Energy-efficient duty point matching, soft-start, and dynamic braking.
Standard control protocols (Modbus and others) for integration into utility / facility SCADA systems. Engineering support included.
FST and Auto Control Panels support remote start/stop — no field visit required for routine operation.
Three control panel tiers based on pump HP, automation requirements, and remote-control needs. All NEMA 3R rated for outdoor installation.
| Feature | Manual CP | Auto CP | VFD |
|---|---|---|---|
| Components | Circuit breaker only | Circuit breaker + contactor | Circuit breaker + VFD |
| Remote Capability | No | Yes (via input contacts) | Yes (via input contacts) |
| Recommended HP Range | Up to 60 HP | Up to 200 HP | 20 – 400 HP |
| Enclosure | NEMA 3R | NEMA 3R | NEMA 3R |
| Motor Speed | 60 Hz fixed | 60 Hz fixed | 0 – 60 – 120 Hz variable |
| Speed Control | Instant, fixed | Instant, fixed | Ramped, variable |
| Auto Speed Adjust | No | No | Yes |
Source: Godwin Product Catalog 07.2015 (US). All panels suitable for Godwin electric Dri-Prime, Heidra, Wellpoint, and Rotary Lobe pumps.
Controls are sized and configured per pump and application. The most common configurations:
Control selection is driven by the pump installation type — portable, semi-permanent, permanent, or backup.
PrimeGuard 2 standard. Optional FST for fleet visibility. Manual start typical for daily-attended portable use.
Auto Control Panel for unattended operation; VFD for variable-speed energy efficiency.
PrimeGuard 2 with FST is standard — critical infrastructure requires remote monitoring of backup-system readiness.
Auto Control Panel or VFD with level-float or level-transducer input. SCADA integration to existing utility system.
VFD for flow / pressure control. SCADA integration for plant-wide visibility.
FST for fleet-wide visibility, run-hour tracking, fault notification, and remote diagnosis. Reduces unplanned service calls.
PrimeGuard 2, FST, or VFD — we configure the right control package for your application. Quote within 24 hours.
Tell us the pump model, application, and SCADA requirements — sized panel within 24 hours.