Zoeller 6221 Solids Handling Sewage Pump - 7.5 HP

Voltage: 230V 1Ph
Build: 35 ft Cord, 4 in Disch, Vortex Imp, SiC-SiC Seals
Part No.: 6221-0162

Product variant with selected options does not exist!

Price
$10,938
Coupon 5% off applied automatically in your cart. No code needed.
SKU: 6221-0162
Weight : 425.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Zoeller · Solids Handling Sewage Pump
Zoeller 6221 62 HD Solids Handling Sewage Pump - 7.5 HP
7.5 BHP · 1750 RPM · 3 in solids · 4 in or 6 in flange · 62 HD Series
7.5 BHP
1750 RPM
3 in Solids
4 in or 6 in Flange
Tandem Seals
Explosion Proof Builds
Overview

The Zoeller Model 6221 is the 7.5 BHP member of the 62 HD Series, Zoeller Engineered Products’ 4 in and 6 in flanged discharge solids handling pumps for municipal and commercial lift stations. A ductile iron semi-open impeller (7-3/8 in standard) passes 3 in solids; vortex and high head hydraulics are available.

Every build in this listing is a configured Zoeller part number: voltage, discharge size, cord length, seals, impeller trim and explosion proof construction are fixed by the part number.

  • Tandem mechanical seals: upper carbon/ceramic, lower silicon carbide/silicon carbide (optional SiC/SiC upper, Viton elastomers)
  • Thermal sensors with automatic reset and moisture sensing probes (require a circuit in the control panel)
  • Class F insulation, 311 °F maximum stator temperature
  • 416 stainless steel motor shaft, ANSI B16.1 flanges
  • 24 in recommended fluid level for continuous operation; 104 °F maximum water temperature
MADE TO ORDER · LEAD TIME 4-6 WEEKS ARO
Zoeller builds each unit to the part number ordered. Lead time runs from receipt of order.
What Ships and What It Needs to Run

Included: the Zoeller pump built to the part number selected, with the cord length and options in that build.

Needs to run: a control panel matched to the pump voltage, phase and full load amps; three phase builds and builds with thermal or moisture sensors need panel circuits for those sensors. Zoeller Pivot panels and our team can match one to the pump.

Genuine Zoeller equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Zoeller Distributor.
Warranty: Zoeller Engineered Products’ standard warranty is 18 months from date of manufacture, 12 months from date of purchase or 12 months from start-up with a start-up report on file with Zoeller. Permanent municipal sewage installations carry Zoeller’s five-year (10,000 hour) prorated limited warranty. Conditions are in the owner’s manual.
Specifications
Model 6221, 7.5 BHP
Speed 1750 RPM
Standard Impeller Ductile iron semi-open, 7-3/8 in; vortex optional; high head hydraulic on 4 in discharge
Solids 3 in spherical
Discharge 4 in or 6 in horizontal flange (ANSI B16.1)
Power Cord 25 ft standard, SOOW sized by amps (#12-4, #8-4 or #4-4)
Pump Weight 350 lb
NEC Locked Rotor Code / Max kW F / 7.8 kW
Full Load Amps 230V 1Ph 36.7 · 200V 3Ph 25.0 · 230V 3Ph 22.0 · 460V 3Ph 11.0
Motor Options Standard submersible; inverter duty (30-60 Hz); dry pit and high temperature on 5-10 BHP (factory)

From Zoeller Engineered Products Tech Data ZM2349 and Zoeller price data.

Models & Performance — Will It Do What You Need?

Find your total dynamic head (vertical lift plus pipe friction) and read across to the flow you need. Each row is a standard impeller; the build you select may carry a trimmed impeller sized to a design point.

Total head in feet at each flow

Model 0 GPM (Shut-off) 170 GPM 420 GPM 640 GPM 850 GPM
6221 · 7.5 BHP, 7-3/8 in 57 46 33 22 10

Read from Zoeller’s vector performance curve (Zoeller Engineered Tech Data ZM2349, standard semi-open impeller (7-3/8 in)) and rounded down to the whole foot. Curve ends: 6221 · 7.5 BHP, 7-3/8 in at 853 GPM. Trimmed impellers and the full curves are on the curve images and the Data Sheet tab; a trimmed build delivers less head than the standard impeller shown.

Builds in This Listing

Pick the voltage, then the build: each build names the cord length, discharge, seals, sensors and impeller trim that Zoeller assembles for that part number.

Before You Buy — The Limits That Decide the Fit
Voltage and Phase Match the site supply exactly; three phase pumps need a three phase panel and starter.
Duty Point Check the flow and total dynamic head against the performance curve (images and Data Sheet tab). Trimmed impeller builds are cut to a specific duty point.
Sensors Thermal and moisture sensors only protect the pump when the control panel has circuits wired for them.
Explosion Proof Explosion proof builds are for classified hazardous locations; confirm the area classification with the engineer of record.
Lead Time Made to order: 4-6 weeks after receipt of order. Plan the install date around it.
Applications
  • Municipal and commercial sewage lift stations
  • Wet well and rail-mounted pump stations
  • Industrial wastewater transfer
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036. © Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.