Menu
Product variant with selected options does not exist!
files/Zoeller_4-in-Turbine-Effluent-5030-5031-and-most-5032-2021_b9465b51-efc7-4f42-b5be-f577ec27fab1.jpg
08:44 PM
The Zoeller 5030 Series Turbine Effluent Pump line is listed here as one family of 7 builds (models 5030, 5031, 5032, 5033, 5034, 5035), 1/2 to 3/4 HP. Pick the horsepower or flow class in the options; the model and its maximums show in the last option, and Zoeller’s printed performance for every model is in the tables below.
Included: the pump end and motor, assembled, with its lead. Zoeller ships these pumps complete with the starting components where the motor needs them.
Pump vault or flow inducer, dosing control and floats: sized to the system and ordered separately. See the Zoeller STEP Septic Tank Effluent Pump Vault.
Zoeller lists a 1-year limited warranty on this product. The start date and conditions are in Zoeller’s published warranty statement.
| Horsepower | 1/2 to 3/4 HP |
| Voltage | 115V 1Ph or 230V 1Ph |
| Solids Handling | 3/32 in |
| Discharge | 1-1/4 in NPT |
| Shipping Weight | 26-30 lb |
From Zoeller’s published product specifications. Shipping weight is the boxed weight Zoeller publishes.
One block per model; open the model you are sizing.
Flow in GPM by total dynamic head
| Total head | 5030-0005, 1/2 HP | 5030-0007, 1/2 HP |
|---|---|---|
| 40 ft | 14.4 | 14.5 |
| 80 ft | 12.1 | 13.1 |
| 120 ft | 9.4 | 11.6 |
| 160 ft | 5.5 | 9.6 |
| 200 ft | — | 7.1 |
| 240 ft | — | 2 |
| Shut-off head | 177 ft | 241 ft |
Zoeller performance table 015413 for this series, verbatim. The full curve is in the image gallery.
Flow in GPM by total dynamic head
| Total head | 5031-0009, 1/2 HP |
|---|---|
| 40 ft | 24.4 |
| 80 ft | 20.5 |
| 120 ft | 15.2 |
| Shut-off head | 159 ft |
Zoeller performance table 015414 for this series, verbatim. The full curve is in the image gallery.
Flow in GPM by total dynamic head
| Total head | 5032-0016, 1/2 HP |
|---|---|
| 20 ft | 32.9 |
| 40 ft | 30.1 |
| 60 ft | 26.4 |
| 80 ft | 22.3 |
| 100 ft | 16.1 |
| 120 ft | 5 |
| Shut-off head | 121 ft |
Zoeller performance table 015045 for this series, verbatim. The full curve is in the image gallery.
Flow in GPM by total dynamic head
| Total head | 5033-0005, 1/2 HP |
|---|---|
| 30 ft | 46 |
| 40 ft | 42 |
| 50 ft | 36 |
| 60 ft | 28 |
| Shut-off head | 68 ft |
Zoeller performance table CL1014-5030-Series-Turbine-1.pdf for this series, verbatim. The full curve is in the image gallery.
Flow in GPM by total dynamic head
| Total head | 5034-0007, 3/4 HP |
|---|---|
| 25 ft | 72.5 |
| 50 ft | 51.1 |
| Shut-off head | 65.6 ft |
Zoeller performance table 015649 for this series, verbatim. The full curve is in the image gallery.
Flow in GPM by total dynamic head
| Total head | 5035-0005, 3/4 HP |
|---|---|
| 25 ft | 45.5 |
| Shut-off head | 30.5 ft |
Zoeller performance table 015845 for this series, verbatim. The full curve is in the image gallery.
| Liquid and solids | Screened septic tank effluent; passes 3/32 in solids. |
| Head | A high-head, low-flow pump: size it on the curve at your system head. |
| Power | 115V 1Ph, 60 Hz. |
| Discharge | 1-1/4 in NPT |
| Installation | Runs in a pump vault or flow inducer so effluent passes the motor. |
Zoeller parts commonly ordered with this pump.
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.
Sign up for our newsletter and be the first to know about coupons and special promotions.