The 64 HD Series are Zoeller Engineered Products’ largest solids handling pumps: 25 to 60 BHP, 1725 RPM submersible motors driving a ductile iron two-vane enclosed impeller (vortex optional) for municipal lift stations. The 4 in discharge is the high head design passing 3-1/8 in solids; the 6 in discharge is the high flow design passing 4 in solids.
Included: the Zoeller pump built to the part number selected, with the cord length and options in that build.
Needs to run: a control panel matched to the pump voltage, phase and full load amps; three phase builds and builds with thermal or moisture sensors need panel circuits for those sensors. Zoeller Pivot panels and our team can match one to the pump.
| Models | 6424 (25 BHP), 6425 (30), 6426 (40), 6427 (50), 6428 (60) |
| Speed | 1725 RPM |
| Impeller | Ductile iron 2-vane enclosed; vortex optional |
| Standard Impeller Diameter, 4 in / 6 in | 6424 9-7/8 / 9-1/8 · 6425 10-3/8 / 9-1/2 · 6426 11-3/8 / 10-1/8 · 6427 12-1/8 / 10-5/8 · 6428 12-7/8 / 11 in |
| Solids | 4 in discharge 3-1/8 in · 6 in discharge 4 in |
| Discharge | 4 in or 6 in horizontal flange, ANSI B16.1 Class 125 |
| Power Cord | 25 ft or 50 ft, #2-4 SOOW; sensor cord #18-5 |
| Pump Weight | 825 lb (4 in) / 850 lb (6 in) |
| Full Load Amps, 460V 3Ph | 34 / 40 / 52 / 62 / 75 A |
| Min Fluid Level, Continuous | 36 in |
From Zoeller Engineered Products Tech Data ZM2969 and Zoeller price data.
Find your total dynamic head (vertical lift plus pipe friction) and read across to the flow you need. Each row is a standard impeller; the build you select may carry a trimmed impeller sized to a design point.
Total head in feet at each flow
| Model | 15 GPM (curve start) | 380 GPM | 940 GPM | 1410 GPM | 1880 GPM |
|---|---|---|---|---|---|
| 6424 · 25 BHP, 9-1/8 in | 70 | 59 | 45 | 33 | 21 |
| 6425 · 30 BHP, 9-1/2 in | 83 | 69 | 54 | 42 | 27 |
| 6426 · 40 BHP, 10-1/8 in | 101 | 86 | 70 | 56 | 42 |
| 6427 · 50 BHP, 10-5/8 in | 115 | 98 | 82 | 70 | 56 |
| 6428 · 60 BHP, 11 in | 125 | 110 | 92 | 80 | 66 |
Read from Zoeller’s vector performance curve (Zoeller Engineered Tech Data ZM2969, high flow models with 6 in flanged discharge, standard enclosed impellers; the 4 in high head design is on the curve images) and rounded down to the whole foot. Curve ends: 6424 at 1920 GPM; 6425 at 2129 GPM; 6426 at 2485 GPM; 6427 at 2446 GPM; 6428 at 2618 GPM. Trimmed impellers and the full curves are on the curve images and the Data Sheet tab; a trimmed build delivers less head than the standard impeller shown.
Pick the model, then the voltage, then the build: each build names the cord length, discharge, seals, sensors and impeller trim that Zoeller assembles for that part number.
| Voltage and Phase | Match the site supply exactly; three phase pumps need a three phase panel and starter. |
| Duty Point | Check the flow and total dynamic head against the performance curve (images and Data Sheet tab). Trimmed impeller builds are cut to a specific duty point. |
| Sensors | Thermal and moisture sensors only protect the pump when the control panel has circuits wired for them. |
| Explosion Proof | Explosion proof builds are for classified hazardous locations; confirm the area classification with the engineer of record. |
| Lead Time | Made to order: 4-6 weeks after receipt of order. Plan the install date around it. |