Dresser Quick-Cam Regular Range Repair Clamp - Stainless, Outlet

Nominal Size - OD Range: 3 in - 3.46-3.70 in OD
Width: 7-1/2 in
Outlet - Part No.: 1/2 in NPT - QCRS-07-0370-505RR-N

Product variant with selected options does not exist!

Price
$569.16
Coupon 5% off applied automatically in your cart. No code needed.
SKU: QCRS-07-0370-505RR-N
Weight : 3.5 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Dresser · Repair Clamp
Quick-Cam Regular Range Repair Clamp
Regular Range full-circle repair clamp with tapped outlet for water mains.
150 PSI Max Working Pressure
180°F Max Continuous
NSF/ANSI 61 SBR Gasket
Regular Range
NPT or CC Outlet
3.5-21 lb Weight
Overview

The Quick-Cam wraps the pipe and closes with cam lugs that carry a built-in handle, sealing leaks, holes and breaks with a waffled mat gasket and multi O-ring seal beads. Its tapped outlet lets you connect a service or test line through the clamp.

Application: Leak and break repair on ductile iron, cast iron, steel, PVC and asbestos cement water mains.

  • Removable lug system for tight spaces
  • Widths 7-1/2 in to 24 in
What Ships and What It Needs to Run

Included: clamp with gasket, lugs, bolts and nuts, assembled.

Genuine Dresser equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
12-Month Dresser Warranty

Covered for 12 months from the date of purchase under Dresser’s published warranty terms.

Working Pressure

Up to 150 PSI maximum working pressure on water and sewer lines, at up to 180°F, tested per AWWA C230-16 on a full 360-degree beam break. Regular Range clamps cover a narrower OD band per clamp than the Extended Range. The allowable pressure on any job also depends on the pipe diameter, material and connection, and never exceeds the rating of the pipe.

Source: Dresser Quick-Cam Repair Clamp brochure (DUS.DPSW.011), Quick-Cam RR technical details. The rating on the product label is the actual rating of each part.

Materials Specifications
Band 18-8 stainless steel
Gasket SBR rubber, NSF 61, for water and sewer service
Alignment lugs ASTM A351 CF8 18-8 stainless steel, cam lug with handle
Bolts Track head, 18-8 Type 304 stainless, ASTM A193 B8, fluoroelastomer coated

Source: Dresser Quick-Cam Repair Clamp brochure (DUS.DPSW.011), Quick-Cam RR technical details.

Pipe Applications

Steel, cast iron, ductile iron, PVC and asbestos cement. The Regular Range is not for HDPE.

Sizes
Nominal Size - OD Range Width
3 in - 3.46-3.70 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
4 in - 4.75-5.14 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
6 in - 6.84-7.24 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
6 in OS - 7.05-7.45 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
8 in - 8.99-9.39 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
8 in OS - 9.27-9.67 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
10 in - 11.04-11.44 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
12 in US - 12.62-13.02 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
12 in - 13.10-13.50 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in
12 in OS - 14.00-14.40 in OD 7-1/2 in, 10 in, 12 in, 15 in, 20 in, 24 in

Sizes as listed in Dresser’s 2026 price lists; the picker shows the part number for each build.

Installation Notes
  • Clean the pipe of rust, scale and debris, and confirm the OD with a pi tape before mounting.
  • Lubricate the pipe, gasket and spanner surfaces with soapy water; do not use pipe lubricant.
  • Center the clamp over the leak; the bolt-head lug can be removed in tight spaces.
  • Tighten the nuts evenly from the center bolts outward to the torque on the product label, using a calibrated torque wrench.
  • Check for leaks, re-tighten if needed, then backfill carefully to give the clamp earth support.

Source: Dresser TPS Quick-Cam Repair Clamp Installation Instructions (INST 1004, Rev E).

Before You Order. Measure the pipe OD with a pi tape: every option is an OD range. The RR fits ductile iron, cast iron, steel, PVC and AC pipe; for HDPE, choose the Extended Range Quick-Cam, since Dresser does not approve the RR on HDPE. Do not reuse a clamp until it is refurbished at the factory. Anchor the pipe: this product seals but does not restrain, and Dresser requires the pipe joint to be anchored wherever pull-out can occur. Non-stock Dresser parts are not returnable without Dresser’s authorization, and ship time is confirmed when you order. Custom builds (other sizes, widths, gaskets or materials) are available: email sales@watermainsupply.com with the pipe OD, material and line content.
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.