Menu
Product variant with selected options does not exist!
files/Zoeller_330-0006-thru-333-0006-lawn-sprinkler_14f93c1b-9850-460d-9859-bed02f564448.jpg
08:36 PM
The Zoeller Models 330-333 Self-Priming Lawn Irrigation Pump line is listed here as one family of 4 builds (models 330, 331, 332, 333), 3/4 to 2 HP. Pick the horsepower or flow class in the options; the model and its maximums show in the last option, and Zoeller’s printed performance for every model is in the tables below.
Our Model 330 High-Volume Lawn Sprinkler Pump boasts impressive capacity and volume, featuring a robust cast iron pump body and mounting ring for extended durability. Powered by a Service Plus NEMA J motor, equipped with capacitor start and double ball bearings, this pump ensures continuous operation.
Included: the pump and its motor, preassembled.
Suction and discharge piping, valves and controls: sized to the job and ordered separately.
Zoeller lists a 1-year limited warranty on this product. The start date and conditions are in Zoeller’s published warranty statement.
| Horsepower | 3/4 to 2 HP |
| Voltage | 115/230V 1Ph |
| Impeller Material | Engineered Plastic |
| Shipping Weight | 64-77 lb |
From Zoeller’s published product specifications. Shipping weight is the boxed weight Zoeller publishes.
One block per model; open the model you are sizing.
Capacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.
| Suction lift | 10 PSI | 15 PSI | 20 PSI | 25 PSI | 30 PSI | 35 PSI | Shut-off |
|---|---|---|---|---|---|---|---|
| 5 ft | 56 | 48 | 42 | 37 | 29 | 21 | 41 PSI |
| 15 ft | 47 | 42 | 37 | 29 | 22 | 12 | 37 PSI |
| 25 ft | 43 | 37 | 31 | 22 | 10 | — | 33 PSI |
Zoeller Technical Data, Lawn Sprinkler Pumps, FM3543, verbatim. A dash is a pressure the pump does not reach at that lift. Feet of head = PSI x 2.31. Do not exceed the maximum case pressure or liquid temperature.
Capacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.
| Suction lift | 10 PSI | 15 PSI | 20 PSI | 25 PSI | 30 PSI |
|---|---|---|---|---|---|
| 5 ft | 58 | 53 | 48 | 43 | 38 |
| 15 ft | 53 | 48 | 45 | 37 | 31 |
| 25 ft | 48 | 44 | 38 | 33 | 25 |
| Suction lift | 35 PSI | 40 PSI | 45 PSI | Shut-off |
|---|---|---|---|---|
| 5 ft | 32 | 23 | 11 | 48 PSI |
| 15 ft | 24 | 12 | — | 43 PSI |
| 25 ft | 14 | — | — | 39 PSI |
Zoeller Technical Data, Lawn Sprinkler Pumps, FM3543, verbatim. A dash is a pressure the pump does not reach at that lift. Feet of head = PSI x 2.31. Do not exceed the maximum case pressure or liquid temperature.
Capacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.
| Suction lift | 10 PSI | 15 PSI | 20 PSI | 25 PSI | 30 PSI |
|---|---|---|---|---|---|
| 5 ft | 78 | 77 | 74 | 70 | 62 |
| 15 ft | 70 | 68 | 66 | 62 | 53 |
| 25 ft | 47 | 46 | 45 | 44 | 42 |
| Suction lift | 35 PSI | 40 PSI | 45 PSI | Shut-off |
|---|---|---|---|---|
| 5 ft | 53 | 43 | 30 | 47 PSI |
| 15 ft | 43 | 30 | — | 41 PSI |
| 25 ft | 34 | — | — | 36 PSI |
Zoeller Technical Data, Lawn Sprinkler Pumps, FM3543, verbatim. A dash is a pressure the pump does not reach at that lift. Feet of head = PSI x 2.31. Do not exceed the maximum case pressure or liquid temperature.
Capacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.
| Suction lift | 10 PSI | 15 PSI | 20 PSI | 25 PSI | 30 PSI |
|---|---|---|---|---|---|
| 5 ft | 86 | 84 | 81 | 77 | 71 |
| 15 ft | 76 | 74 | 72 | 69 | 64 |
| 25 ft | 52 | 51 | 50 | 47 | 45 |
| Suction lift | 35 PSI | 40 PSI | 45 PSI | Shut-off |
|---|---|---|---|---|
| 5 ft | 62 | 52 | 40 | 50 PSI |
| 15 ft | 55 | 43 | 25 | 45 PSI |
| 25 ft | 42 | 30 | — | 40 PSI |
Zoeller Technical Data, Lawn Sprinkler Pumps, FM3543, verbatim. A dash is a pressure the pump does not reach at that lift. Feet of head = PSI x 2.31. Do not exceed the maximum case pressure or liquid temperature.
| Water | Clear water service; Zoeller lists no drinking water certification on this sheet. |
| Suction | Up to 25 ft of suction lift; capacity falls as lift rises. Self-priming once the case is filled. |
| Maximum pressure | Differs by model; see the performance tables above. |
| Power | 115/230V 1Ph, 60 Hz. |
| Connections | 2 in suction, 1-1/2 in discharge. |
| Liquid temperature | 180°F maximum. |
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.
Sign up for our newsletter and be the first to know about coupons and special promotions.