Menu
Product variant with selected options does not exist!
files/Zoeller_292-0014_55ed5b38-54cd-44b6-8828-3dac3e2b3603.jpg
07:55 PM
The Zoeller Model 295 Sewage Pump is a 2 HP sewage pump with a 2 in NPT discharge that passes 2 in solids. Printed performance runs from 214 GPM at 5 ft of total head to shut-off at 75 ft. It is listed here in 46 builds: 200-208V or 230V 1Ph · 200-208V, 230V or 460V 3Ph, with 20 to 50 ft cords.
The Model 295 sewage ejector pump is a powerful 2 HP member of Zoeller's High Head Waste-Mate series, engineered for demanding commercial, municipal, and multi-unit residential wastewater applications. Constructed entirely from cast iron-including the motor housing, pump housing, and vortex impeller-the Model 295 is built for rugged environments that require reliable solids handling, thermal durability, and long-term performance.
Which switch fits your pit? Vertical Float builds carry Zoeller’s snap-action float switch on the pump, with fixed on and off levels, and suit narrow pits. Wide-Angle Float builds use a tethered wide-angle float for a long pumping range in larger basins. No Switch builds are Zoeller’s nonautomatic models: they run from a separate piggyback float or a control panel.
Included: the pump with its power cord; Vertical Float and Wide-Angle Float builds ship with that switch.
Float switch or control panel required, ordered separately, on No Switch builds. Zoeller’s nonautomatic models run from an external float switch or a control panel: see the Zoeller Piggyback Pump Switch and the Zoeller Pivot Control Panel.
Motor starter required, ordered separately, on three-phase builds: they run from a control panel with a magnetic starter and overload protection, such as the Zoeller Pivot Pro Control Panel.
Basin, check valve and discharge pipe: sized to the installation and ordered separately.
Zoeller lists a 1-year limited warranty on this product. The start date and conditions are in Zoeller’s published warranty statement.
| Horsepower | 2 HP |
| Voltage | 200-208V or 230V 1Ph · 200-208V, 230V or 460V 3Ph |
| Shaft Seal | Single, Double |
| Operation | Automatic, Nonautomatic |
| Switch | Snap-Action, Wide Angle, None |
| Amps | 17.1 |
| RPM | 3450 |
| Discharge | 2 in NPT |
| Solids Handling | 2 in (50 mm) spherical solids |
| Impeller Material | Cast Iron |
| Impeller Type | Vortex |
| Cord Length | 20, 25, 35, 50 ft |
| Boxed Size | 21-1/4 H x 11-3/4 W x 14-3/4 L in |
| Shipping Weight | 87-104 lb |
From Zoeller’s published product specifications. Shipping weight is the boxed weight Zoeller publishes.
Find your total dynamic head (vertical lift plus pipe friction) in the left column and read the flow beside it.
Flow in GPM by total dynamic head
| Total head | Model 295 |
|---|---|
| 5 ft | 214 |
| 10 ft | 199 |
| 15 ft | 186 |
| 20 ft | 173 |
| 25 ft | 161 |
| 30 ft | 149 |
| 35 ft | 137 |
| 40 ft | 124 |
| 50 ft | 98 |
| 55 ft | 83 |
| 60 ft | 66 |
| 70 ft | 23 |
| Shut-off head | 75 ft |
Printed points from Zoeller Performance Curve, 290 Series, 009919, verbatim. A dash means the pump does not reach that head. Shut-off head is where flow stops; pick a pump whose shut-off sits well above your total head. The full curve is in the image gallery and on the Data Sheet tab.
| Liquid and solids | Passes 2 in solids. |
| Lift | Flow stops at 75 ft of total head. Size on the flow at your own head, not on the maximum. |
| Switch | Vertical Float; Wide-Angle Float; No Switch. No Switch builds need a float or panel. |
| Power | 200-208V or 230V 1Ph · 200-208V, 230V or 460V 3Ph, 60 Hz. Match the build to the supply at the basin. |
| Discharge | 2 in NPT |
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.
Sign up for our newsletter and be the first to know about coupons and special promotions.