Find your horsepower in the row. Total head is the depth to the pumping water level, plus 2.31 ft for every PSI you want at the tank, plus drop-pipe friction. The two output tables below do that sum for a 30/50 PSI pressure switch.
Total head in feet, by flow
| HP |
0 GPM (Shut-off) |
5 GPM |
13 GPM |
20 GPM |
26 GPM |
| 0.75 HP |
196 ft |
186 ft |
166 ft |
136 ft |
100 ft |
| 1 HP |
263 ft |
252 ft |
216 ft |
179 ft |
120 ft |
| 1.5 HP |
321 ft |
306 ft |
260 ft |
216 ft |
140 ft |
DAB prints flow at each depth and discharge pressure rather than a head-at-flow table (S4 Technical Sheet 60191756, p. 12). Each head here is the highest total head, depth plus DAB’s own foot equivalent of the pressure, at which DAB prints at least that flow, so it never claims more than DAB’s grid. 0 GPM is DAB’s printed shut-off; 26 GPM is the highest flow every build reaches; DAB prints flows to 26-28 GPM by model.
Output in GPM at 30 PSI (switch cut-in), by depth to pumping water
| HP |
40 ft |
60 ft |
80 ft |
100 ft |
120 ft |
140 ft |
180 ft |
| 0.75 HP |
24 |
21 |
16 |
11 |
— |
— |
— |
| 1 HP |
— |
— |
24 |
21 |
19 |
15 |
5 |
| 1.5 HP |
— |
— |
— |
24 |
20 |
20 |
15 |
Output in GPM at 50 PSI (switch cut-out), by depth to pumping water
| HP |
40 ft |
60 ft |
80 ft |
100 ft |
120 ft |
140 ft |
180 ft |
| 0.75 HP |
17 |
8 |
— |
— |
— |
— |
— |
| 1 HP |
23 |
20 |
18 |
15 |
8 |
— |
— |
| 1.5 HP |
— |
23 |
21 |
20 |
16 |
14 |
8 |
As printed in the DAB S4 Technical Sheet (60191756), p. 12, at the 30 and 50 PSI rows. DAB’s figures exclude drop-pipe friction and are for a pump without check valve. — = DAB prints no figure there.
3-Wire control box by horsepower (ordered separately; 2-Wire builds need none)
| HP |
Voltage |
DAB 4CBUS control box |
| 0.75 HP |
230V 1Ph |
60174731 |
| 1 HP |
230V 1Ph |
60174732 |
| 1.5 HP |
230V 1Ph |
60174733 (Basic) or 60174737 (Plus, adds a line contactor) |
Enter your water level, pipe run and pressure. The calculator shows which DAB pumps cover the duty, with the headroom on each.