A.Y. McDonald · Pump Protection
QD Pumptec
Plug-in load and voltage protection for Franklin QD relay control boxes and Franklin 230V 3-wire motors, 1/3 to 1 HP.
3-Second Dry-Well Trip
1/3-1 HP
230V 1Ph
Franklin 3-Wire Motors
Fits Franklin QD Relay Boxes
No Wiring or Tools
Restart 2-240 min
1 lb Weight
What Ships and What It Needs to Run
Included: the QD Pumptec plug-in module and its “Protected by Pumptec” label (Baker part 6617-145, Franklin Electric 5800070600).
Required, ordered separately: a Franklin Electric QD relay control box for a Franklin 230V 3-wire motor. The module plugs onto the box’s L1 and L2 terminals and lives inside it.
Fits: Franklin 230V three-wire submersible motors, 1/3 to 1 HP. It estimates motor load from power factor, so non-Franklin motors may not be protected reliably.
Overview
QD Pumptec is a solid-state sensing device designed exclusively for Franklin Electric QD relay control boxes and Franklin 230V three-wire motors. Its microcontroller continuously monitors line voltage and motor current and shuts off the motor on over voltage, under voltage or a dry well. A dry well is detected when the motor load stays below the factory preset or field-calibrated level for more than 3 seconds; the unit then restarts automatically after the timeout you select, from 2 to 240 minutes.
It plugs into a 3-wire QD relay control box in minutes, with no extra wiring or tools. Two knobs set the restart timeout and the underload sensitivity, or switch it to a field calibration that learns your system’s own load.
-
Dry well protection — factory set to trip at about 70% of motor service factor load.
-
Adjustable sensitivity — ±10% or ±20%, or a field calibration snapshot.
-
Over and under voltage — stops the motor for 2 minutes, then restarts automatically.
-
Excess current — stops the motor on 16 to 17 A for 3 seconds; restart by removing power for 15 seconds.
Genuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.
12-Month Franklin Electric Warranty
Covered for 12 months from the date of installation, and no more than 24 months from the date of manufacture, under Franklin Electric’s standard limited warranty. A.Y. McDonald warrants items it does not manufacture to the extent of the original manufacturer’s warranty.
Check the Part Number Before You Compare
This is Baker part 6617-145, supplied by A.Y. McDonald under the Baker number. Franklin Electric sells the same module as order number 5800070600.
Which Pumptec Is Right for Your Well?
| Protects against |
QD Pumptec |
Pumptec |
Pumptec-Plus |
| Air or gas locked pump (cavitation) |
● |
● |
● |
| Broken shaft or coupling |
● |
● |
● |
| Clogged well screen |
● |
● |
● |
| Drop in water level |
● |
● |
● |
| Faulty check valve |
— |
● |
● |
| High voltage |
● |
● |
● |
| Low voltage |
● |
● |
● |
| Low yield wells |
● |
● |
● |
| Rapid cycling |
— |
● |
● |
| Waterlogged tank |
— |
● |
● |
| Worn pump parts |
● |
● |
● |
| Motor size |
1/3 to 1 HP |
1/3 to 1 1/2 HP |
1/2 to 5 HP |
| Supply |
230V, 60 Hz |
115V or 230V, 50/60 Hz |
230V, 60 Hz |
| Mounting |
Inside a Franklin QD relay control box |
Indoor or outdoor enclosure |
Indoor or outdoor enclosure |
| Indicator lights |
No |
Yes: power, load, voltage |
Yes: green, yellow, red |
| Underload setting |
Factory, ±20% or field calibrate |
Adjustable 40 to 90% SFL |
Snapshot calibration, ±25% |
| Restart timer |
2 to 240 min |
2 to 120 min |
Manual, or 1 min to 4 hr 16 min |
| Alarm contacts |
No |
Yes, 1 A |
No |
Source: Franklin Electric Single-Phase Pump Protection brochure M1409 (01/17) and the three owner’s manuals. SFL = motor service factor load.
Specifications
| Baker part number |
6617-145 |
| Franklin Electric order number |
5800070600 |
| Motor horsepower |
1/3 to 1 HP |
| Motor type |
Franklin 230V three-wire single-phase |
| Mounting |
Plugs into a Franklin QD relay control box |
| Voltage |
230V |
| Frequency |
60 Hz (brochure); the installation manual lists 50/60 Hz |
| Response time |
3 seconds |
| Underload trip |
About 70% of service factor load at the factory setting |
| Sensitivity adjustment |
±20%, or field calibrate |
| Reset time adjustment |
2 to 240 minutes |
| Over / under voltage trip |
255 VAC / 203 VAC (manual specification table) |
| Voltage fault time-out |
2 minutes, then automatic restart |
| Overcurrent trip |
16 to 17 A for 3 seconds |
| Indicator lights |
None |
| Operating temperature |
-15 °F to 130 °F |
| Weight |
1 lb |
Sources: Franklin Electric QD Pumptec Installation Manual 225559101 Rev. 6 (01.13); Single-Phase Pump Protection brochure M1409 (01/17); Pumps by Baker catalog rev 3/26, p. 134.
Installation
- Turn off power at the source and remove the control box cover.
- Unplug the blue, yellow and red wires from the L1, L2 and Start positions on the terminal strip.
- Slide the tail of the QD Pumptec under the start capacitor and rock its terminal side down onto the L1 and L2 terminals. Make sure it seats firmly.
- Connect the blue wire to L1 and the yellow wire to L2 on the QD Pumptec.
- Reconnect the red wire to its original Start terminal on the control box strip.
- Set the timeout knob (restart time after an underload trip).
- Leave the sensitivity on “Factory Setting” for most installations.
- Replace the cover, reconnect power and apply the “Protected by Pumptec” label to the box cover.
Calibration and Sensitivity
| Knob position |
What it does |
| Factory Setting |
Calibrated for Franklin 230V three-wire motors; trips at about 70% of service factor load. Right for most wells |
| +10% / +20% |
More sensitive: trips at 80% / 90% of service factor load. Use for a low-yield well pumping into a restriction |
| −10% / −20% |
Less sensitive: trips at 60% / 50%. May fail to detect a dry well |
| Field Calibrate |
On the next power-up it runs 15 seconds, records the load, stops 10 seconds, then restarts and protects against that snapshot. To redo it, return the knob to Factory Setting, apply power, then field calibrate again |
Troubleshooting
| Symptom |
What to check |
| Trips in 3 seconds while delivering water |
Pump and motor not matched (for example a 1/3 HP pump on a 1/2 HP motor underloads it); line voltage above 253V or below 207V; or motor current too high (16 to 17 A), which points to a clogged or bound pump or motor |
| Trips in 3 seconds with no water |
Dry well or deadhead: wait for the well to recover. Also check for a broken shaft or coupling (current near no-load) or an air- or gas-locked pump |
| Does not trip when the pump breaks suction |
The module is designed for Franklin motors; other motors may not show the same load and power factor relationship |
| Nuisance trips on a low-yield well into a restriction |
Turn sensitivity to the positive side, for example +10% |
Before You OrderQD Pumptec fits only Franklin Electric QD relay control boxes on Franklin 230V three-wire motors, 1/3 to 1 HP. For other control boxes or 2-wire motors, choose Pumptec or Pumptec-Plus. Deadhead detection is not guaranteed: not every pump unloads its motor when deadheaded.