Franklin Electric HCL6410 Flanged Centrifugal Pump

HP - Voltage: 7-1/2 HP - 230/460V 3Ph
Motor Enclosure: TEFC
Model - Max: 7HCL6410-CTMJAA - 29 PSI Max, 482 GPM Max

Product variant with selected options does not exist!

Price
$9,901.75
SKU: 35060410106
Weight : 300.9993 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Franklin Electric · Close-Coupled End Suction Pump
HCL6410 Flanged
4 in discharge x 6 in suction close-coupled end suction pump, 10 in nominal impeller, 7-1/2-15 HP at 1,800 RPM.
67-120 ft (29-52 PSI) Max Head · 482-599 GPM Max
7-1/2-15 HP
230/460V 3Ph or 230V 3Ph or 575V 3Ph
4 x 6 in Class 150 Flanged
1,800 RPM TEFC Motor
CA6NM stainless steel Impeller
Back Pull-Out Design
350 PSI Max Working Pressure
212 °F Max Temperature
292-573 lb Weight
Overview

The HC Series is Franklin Electric’s heavy-duty close-coupled end suction pump for irrigation, commercial, construction, municipal, mining and light industrial service. It has a ductile iron volute, an enclosed CA6NM stainless steel impeller with internal hydraulic balancing for lower bearing load and good NPSH, a silicon carbide mechanical seal, a replaceable shaft sleeve and wear rings, and Class 150 flanged connections.

This listing is the HCL6410 Flanged: 4 in discharge by 6 in suction, Class 150 Flanged connections, 7-1/2-15 HP at 1,800 RPM. It is not self-priming: run it with flooded suction or a foot valve and a full suction line. The 3,600 RPM version of this pump, 30 to 50 HP, is the HC 6410.

  • Ductile iron volute, back pull-out, rotates for installation
  • Enclosed CA6NM stainless steel impeller, hydraulically balanced
  • Silicon carbide/silicon carbide mechanical seal with FKM elastomers
  • Replaceable shaft sleeve and wear ring; casing jack-out holes
  • NEMA JP motors, ODP or TEFC; vertical or horizontal mounting
What Ships and What It Needs to Run

Included: the pump end and its NEMA JP frame motor, close-coupled and assembled at the factory, with the impeller trimmed for the motor selected above.

Motor starter or overload protection required, ordered separately. Motors without built-in protection need a contactor and thermal overloads, sized to the motor’s full-load amps.

Suction and discharge piping, valves and gauges: sized to your installation; the suction pipe is the pump’s suction size or larger, with a foot valve where the pump sits above the water.

Genuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
12-Month Warranty

Covered for 12 months from the date of purchase against defects in material and workmanship.

Single Unit

One pump per duty. For more flow at the same head, step up a size in the series; for higher pressure at low flow, see the VR Series vertical multistage pumps.

Specifications
Pump type Close-coupled end suction centrifugal
Size 4 in discharge x 6 in suction, 10 in nominal impeller
Connections Class 150 Flanged
Horsepower 7-1/2-15 HP
Speed 1,800 RPM
Motor NEMA JP frame motor, TEFC
Voltage 230/460V 3Ph, 230V 3Ph, 575V 3Ph
Maximum working pressure 350 PSI
Maximum liquid temperature 212 °F
Rotation Clockwise viewed from the motor end
Performance — Will It Do What You Need?

Pick the row for your motor size, then read the pressure the pump adds at your flow. Shut-off heads run 67-120 ft and the curves end at 482-599 GPM.

Pressure added in PSI at flow

Impeller (Motor HP) Shut-off 110 GPM 290 GPM 440 GPM 599 GPM (Max)
8 in (7-1/2 HP) 29 29 24 15 10 at 482
9 in (10 HP) 36 36 33 25 13 at 559
10-1/4 in (15 HP) 52 49 46 41 31

Digitized from the published impeller curves in the Franklin Electric HC Series Catalog M5095 (p. 14; vector data) and rounded down; PSI shown, feet = PSI × 2.31. Shut-off is the pressure at zero flow, the most the pump adds to its suction pressure. Each row is the impeller trim Franklin pairs with that motor size. Where a curve ends before the last column, its last point is shown in bold with its flow. The full curves are in the image gallery.

Before You Buy — The Limits That Decide the Fit
Water Clean water; Franklin’s warranty excludes saltwater and corrosive liquids
Suction Not self-priming: flooded suction, or a foot valve with the suction line full
Pressure The pump adds pressure to its suction pressure; keep the total under 350 PSI
Power 230/460V 3Ph, 230V 3Ph, 575V 3Ph; starter or overloads by others
Temperature 212 °F maximum
Pairing Single pump; for more flow at the same head, step up a size in the series
Materials of Construction
Volute Ductile iron, ASTM A536
Impeller CA6NM stainless steel
Motor bracket Ductile iron, ASTM A536
Volute wear ring Gray iron, ASTM A48 Class 40
Shaft sleeve 416 stainless steel
Mechanical seal Silicon carbide / silicon carbide / FKM, stainless steel
Accessories and Service Parts
Item Listing Use
Pump end kit HC Series Pump End Kit Pump end without motor, for a motor you already have
Replacement motor JP Close-Coupled Pump Motor Motor for this pump end
Mechanical seal Industrial Centrifugal Pump Mechanical Seal Replacement shaft seal
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036. © Watermain Supply — A division of E4 Industrial LLC
Data Sheet
Videos

Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.

You May Also Like