Find your horsepower in the row, then read across. Total head is the lift from the pumping water level to the discharge, plus the pressure you want at the tank (2.31 ft for every PSI), plus friction in the drop pipe.
Total head in feet · curves end at 38 GPM
| HP |
0 GPM (Shut-off) |
7.5 GPM |
20 GPM |
27.5 GPM |
37.5 GPM |
| 1/2 HP |
120 ft |
118 ft |
95 ft |
75 ft |
38 ft |
| 3/4 HP |
150 ft |
142 ft |
120 ft |
91 ft |
46 ft |
| 1 HP |
210 ft |
196 ft |
163 ft |
133 ft |
62 ft |
| 1 1/2 HP |
270 ft |
259 ft |
211 ft |
169 ft |
84 ft |
| 2 HP |
331 ft |
308 ft |
246 ft |
200 ft |
95 ft |
| 3 HP |
450 ft |
419 ft |
344 ft |
281 ft |
147 ft |
| 5 HP |
777 ft |
721 ft |
602 ft |
485 ft |
256 ft |
| 7 1/2 HP |
1168 ft |
1080 ft |
901 ft |
732 ft |
381 ft |
Read from the published curve in the Pumps by Baker catalog (Sept 2025, rev 3/26), p. 114, digitized and rounded down, at the flows nearest 20%, 50% and 75% of the curve’s 38.1 GPM end. 0 GPM is the printed shut-off. The last column is the last flow every curve reaches; the curve ends are named in the table title.
Output in GPM at 30 PSI (switch cut-in), by depth to water · 1/2–2 HP
| HP |
20 ft |
40 ft |
60 ft |
80 ft |
100 ft |
120 ft |
140 ft |
| 1/2 HP |
22.4 |
9.7 |
— |
— |
— |
— |
— |
| 3/4 HP |
28.4 |
22.6 |
14.8 |
— |
— |
— |
— |
| 1 HP |
— |
31.8 |
28.1 |
23.8 |
17.6 |
8.9 |
— |
| 1 1/2 HP |
— |
— |
33.3 |
30.6 |
27.7 |
24.3 |
19.9 |
| 2 HP |
— |
— |
— |
33.4 |
31.2 |
28.7 |
26.0 |
Output in GPM at 50 PSI (switch cut-out), by depth to water · 1/2–2 HP
| HP |
20 ft |
40 ft |
60 ft |
80 ft |
100 ft |
120 ft |
140 ft |
| 1/2 HP |
— |
— |
— |
— |
— |
— |
— |
| 3/4 HP |
11.4 |
— |
— |
— |
— |
— |
— |
| 1 HP |
25.9 |
22.2 |
15.2 |
— |
— |
— |
— |
| 1 1/2 HP |
32.5 |
29.7 |
26.7 |
23.1 |
18.3 |
11.8 |
— |
| 2 HP |
— |
32.8 |
30.5 |
27.9 |
25.1 |
22.0 |
18.2 |
Output in GPM at 30 PSI (switch cut-in), by depth to water · 3–7 1/2 HP
| HP |
140 ft |
260 ft |
280 ft |
500 ft |
540 ft |
580 ft |
620 ft |
| 3 HP |
33.8 |
22.7 |
19.9 |
— |
— |
— |
— |
| 5 HP |
— |
— |
— |
22.8 |
19.5 |
15.5 |
10.6 |
| 7 1/2 HP |
— |
— |
— |
33.0 |
31.8 |
30.5 |
29.2 |
Output in GPM at 50 PSI (switch cut-out), by depth to water · 3–7 1/2 HP
| HP |
140 ft |
260 ft |
280 ft |
500 ft |
540 ft |
580 ft |
620 ft |
| 3 HP |
30.0 |
15.3 |
11.1 |
— |
— |
— |
— |
| 5 HP |
— |
33.2 |
32.3 |
18.9 |
14.8 |
9.8 |
— |
| 7 1/2 HP |
— |
— |
— |
31.6 |
30.3 |
29.0 |
27.6 |
Output tables as printed in the Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 113-114, at the 30 and 50 PSI rows. Riser-pipe friction is not included (manufacturer note): add it for long or small drop pipe. — marks a point A.Y. McDonald does not print for that horsepower.
Baker 4 in motor by horsepower (230V unless marked, ordered separately)
| HP |
Motor |
| 1/2 HP |
2-wire 3132-005 · 3-wire 3132-004 · 3Ph 3132-525 |
| 3/4 HP |
2-wire 3132-006 · 3-wire 3132-000 · 3Ph 3132-527 |
| 1 HP |
2-wire 3132-007 · 3-wire 3132-001 · 3Ph 3132-529 |
| 1 1/2 HP |
2-wire 3132-009 · 3-wire 3132-002 · 3Ph 3132-531 |
| 2 HP |
3-wire 3132-510 · 3Ph 3132-534 |
| 3 HP |
3-wire 3132-512 · 3Ph 3132-514 |
| 5 HP |
3-wire 3132-513 · 3Ph 3132-517 |
| 7 1/2 HP |
3Ph 3132-520 |
Best operating range: the published curve shades the most efficient operating range for each model; the catalog prints no figures for it. The curve is in the image gallery.