Find your horsepower in the row, then read across. Total head is the lift from the pumping water level to the discharge, plus the pressure you want at the tank (2.31 ft for every PSI), plus friction in the drop pipe.
Total head in feet · curves end at 32–37 GPM
| HP |
0 GPM (Shut-off) |
7.5 GPM |
17.5 GPM |
27.5 GPM |
30 GPM |
| 1/2 HP |
122 ft |
108 ft |
86 ft |
55 ft |
46 ft |
| 3/4 HP |
152 ft |
137 ft |
114 ft |
73 ft |
60 ft |
| 1 HP |
219 ft |
201 ft |
160 ft |
113 ft |
96 ft |
| 1 1/2 HP |
282 ft |
258 ft |
215 ft |
158 ft |
139 ft |
Read from the published curve in the Pumps by Baker catalog (Sept 2025, rev 3/26), p. 50, digitized and rounded down, at the flows nearest 20%, 50% and 75% of the curve’s 37.3 GPM end. 0 GPM is the printed shut-off. The last column is the last flow every curve reaches; the curve ends are named in the table title.
Output in GPM at 30 PSI (switch cut-in), by depth to water
| HP |
25 ft |
50 ft |
75 ft |
100 ft |
125 ft |
150 ft |
175 ft |
| 1/2 HP |
15.93 |
2.93 |
— |
— |
— |
— |
— |
| 3/4 HP |
23.22 |
16.71 |
6.80 |
— |
— |
— |
— |
| 1 HP |
29.81 |
26.22 |
22.15 |
17.35 |
11.16 |
— |
— |
| 1 1/2 HP |
33.65 |
31.08 |
28.30 |
25.26 |
21.85 |
17.91 |
13.07 |
Output in GPM at 50 PSI (switch cut-out), by depth to water
| HP |
25 ft |
50 ft |
75 ft |
100 ft |
125 ft |
150 ft |
175 ft |
| 1/2 HP |
— |
— |
— |
— |
— |
— |
— |
| 3/4 HP |
8.81 |
— |
— |
— |
— |
— |
— |
| 1 HP |
22.80 |
18.14 |
12.24 |
2.61 |
— |
— |
— |
| 1 1/2 HP |
28.74 |
25.74 |
22.40 |
18.56 |
13.90 |
7.42 |
— |
Output tables as printed in the Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 49-50, at the 30 and 50 PSI rows. Riser-pipe friction is not included (manufacturer note): add it for long or small drop pipe. — marks a point A.Y. McDonald does not print for that horsepower.
Baker 4 in motor by horsepower (230V unless marked, ordered separately)
| HP |
Motor |
| 1/2 HP |
2-wire 3132-005 · 3-wire 3132-004 · 3Ph 3132-525 |
| 3/4 HP |
2-wire 3132-006 · 3-wire 3132-000 · 3Ph 3132-527 |
| 1 HP |
2-wire 3132-007 · 3-wire 3132-001 · 3Ph 3132-529 |
| 1 1/2 HP |
2-wire 3132-009 · 3-wire 3132-002 · 3Ph 3132-531 |
Best operating range: the published curve shades the most efficient operating range for each model; the catalog prints no figures for it. The curve is in the image gallery.