Franklin Electric VR SpecPAK Quintuplex Booster System

Boost - Flow: 25 PSI Max Boost - 670 GPM Max
HP - Voltage: 5 x 2 HP - 208-230V 1Ph
Model: SPV5-15VR0100-S2

Product variant with selected options does not exist!

Price
$61,090
SKU: SPV5-15VR0100-S2
Weight : 1225.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
Franklin Electric · Packaged Pressure Boosting System
VR SpecPAK Quintuplex Booster System
Five VR vertical multistage pumps in parallel, a Cerus X-Drive VFD on every pump, and one PLC panel that stages, alternates and reports to the building automation system. 1 to 60 HP per pump, to 3,180 GPM.
25-360 PSI Max Boost · 140-3,180 GPM Max Flow
5 x 1-60 HP
208-230V 1Ph/3Ph, 460V or 575V 3Ph
230-460 PSI Max Working Pressure by Model
Grooved 316SS Headers
Cerus X-Drive VFD on Every Pump
BACnet IP and Modbus TCP
N+1 Standby or All-Duty Sizing
NSF/ANSI/CAN 61 and 372
UL 508A Panel, 100 kA SCCR
Indoor Installation (NEMA 1 Panel)
Overview

The VR SpecPAK is Franklin Electric's engineered booster package for large buildings: five VR Series vertical multistage pumps on one welded frame, each on its own Cerus X-Drive variable frequency drive, run as one system from a PLC panel with a 7 in color touchscreen. It holds a constant discharge pressure from a trickle to full building demand, rotates the lead pump to share the hours, and keeps the building at pressure when a pump, a drive or a pressure sensor is out of service. Franklin builds the VR SpecPAK as a duplex, triplex or quadplex; this five-pump version extends the same hardware for buildings whose demand outgrows a quadplex. It is built for the buildings where low pressure is not an option: data centers, hospitals, high-rise towers, hotels and campuses.

  • Redundant by design — size it N+1 with a pump on standby, a backup discharge transducer that takes over automatically, and drives that keep running when one faults.
  • Talks to the BMS — BACnet IP and Modbus TCP over Ethernet, with data and alarm logs on a 64 GB SD card in the HMI.
  • Serviceable while running — fused branch disconnects and isolation valves on every pump.
  • Power quality — a line reactor ahead of the drives limits harmonics; UL 508A panel rated 100 kA SCCR.
  • Factory proven — hydrostatically tested to its maximum working pressure, hydraulically tested at your design point and shipped programmed.
What Ships and What It Needs to Run

Included: 5 VR pumps with TEFC motors and 5 Cerus X-Drive VFDs, pre-wired; control panel with PLC, 7 in HMI, 64 GB SD card, line reactor, main disconnect and fused branch disconnects; 316 stainless suction and discharge manifolds with two grooved end caps; suction and discharge isolation valves, a silent check valve and a thermal relief valve on every pump; one suction and two discharge pressure transducers with gauges; welded frame with fork pockets; owner's manuals.

Pressure relief valve required, ordered separately. Franklin requires a relief valve sized for full pump flow near the discharge, piped to a drain that can take full system flow.

Site isolation valves, piping and any hydropneumatic tank: sized to the building and supplied by the installer.

Genuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Franklin Electric Warranty — Extendable to 36 Months

Franklin Electric warrants the package against defects in workmanship and material for 12 months from the date of install or 24 months from the date of manufacture, whichever occurs first. A completed and approved Start-Up and Commissioning Checklist extends it to 36 months from the date of installation. The form is on the Data Sheet tab.

Redundancy — N+1 Standby or All Pumps on Duty

Same hardware either way: redundancy is the flow split each pump is sized for against your peak demand.

Flow split Pumps carrying peak With one pump out Where it fits
5 x 25% (N+1) 4, one on standby Full design flow Data centers, hospitals, high-rise domestic water, any building that cannot lose pressure
5 x 20% (all duty) All 5 80% of design flow Lowest cost per GPM where reduced flow during service is acceptable

The Performance tables carry both: Max GPM, all 5 running and Max GPM, one on standby. Same pump models, other pump counts: Duplex · Triplex · Quadplex · Sextuplex.

Controls and Building Integration
Building automation Ethernet RJ45 port for BACnet IP and Modbus TCP; remote enable input and relay outputs for alarms and run status. No app: remote monitoring runs through the BMS
Operator interface 7 in color touchscreen, 800 x 600; system and drive settings from one screen; password levels
Records Pressure and power data logs, timestamped fault log, stored on a 64 GB SD card in the HMI
Pressure sensing Suction transducer plus primary and backup discharge transducers; the backup takes over automatically if the primary fails
Fault tolerance Constant pressure with a failed pump; on a fault or power loss at any VFD the remaining drives keep running
Staging and protection Lead-lag staging with alternation and sleep; low suction shutdown, overpressure, underload (dry run) and stall protection
Specifications
Configuration Quintuplex, 5 pumps in parallel on one welded frame
Pumps Franklin VR vertical multistage, 3VR to 95VR; 1 to 60 HP per pump
Motors NEMA standard TC/TSC frame, close-coupled; standard replacement motors fit
Input power 208-230V 1Ph to 15 HP per pump; 208-230V 3Ph to 30 HP; 460V 3Ph to 60 HP; 575V 3Ph to 50 HP
Control panel UL 508A, NEMA 1, SCCR 100 kAIC minimum; main disconnect and fused branch disconnects
Manifolds 316 stainless steel, grooved ends, either end connects (reversible end caps)
Max working pressure 230, 360, 375 or 460 PSI by model, per Franklin's package drawing
Fluid and ambient To 104°F (40°C), full rating to 3,281 ft altitude; above 104°F Franklin reviews the application
Pump efficiency 56% (3VR) to 79% (95VR) at best efficiency, pump alone, per FE Select
Standards NSF/ANSI/CAN 61 and 372; ASHRAE 90.1-2010 compliant
Models and Performance — Will It Do What You Need?

Every figure is pressure the system adds to what arrives at the suction. Pick the pump family whose flow covers your peak demand, then the model whose pressure at that flow covers your boost. Select Boost - Flow, then voltage, in the options.

Pump family HP per pump Max boost, PSI Max GPM, all 5 running Max GPM, one on standby Pump efficiency at best efficiency
3VR 1-3 77-261 147-149 117-119 56%
6VR 1-7 1/2 46-363 236-264 189-211 64-66%
10VR 1 1/2-15 41-353 481-488 385-391 69%
15VR 2-20 29-357 670-701 536-561 66-70%
20VR 2-20 31-320 752-787 602-629 67-70%
30VR 5-30 48-321 1,115-1,133 892-906 73-74%
45VR 7 1/2-40 49-279 1,741-1,775 1,392-1,420 76-77%
65VR 7 1/2-60 39-272 2,323-2,386 1,858-1,908 77-78%
95VR 15-60 45-220 3,127-3,180 2,501-2,544 78-79%
3VR to 10VR — 18 models, 1-15 HP per pump

Pressure and flow

Model HP 0 GPM (Shut-off) GPM at best efficiency, all 5 Pump efficiency at best efficiency Max GPM, all 5 PSI at max GPM Max GPM, one on standby
3VR05 1 77 83 56.3% 149 5 119
3VR08 1 1/2 124 83 56.3% 149 8 119
3VR11 2 170 83 56.3% 148 11 119
3VR17 3 261 82 56.3% 147 17 117
6VR03 1 46 164 64.0% 239 8 191
6VR05 1 1/2 77 163 64.0% 239 14 191
6VR07 2 108 162 64.0% 238 19 191
6VR11 3 169 161 64.0% 236 30 189
6VR15 5 234 162 65.6% 262 5 209
6VR19 5 294 161 65.7% 260 6 208
6VR23 7 1/2 363 164 65.7% 264 8 211
10VR02 1 1/2 41 296 68.8% 485 3 388
10VR03 2 61 294 68.8% 483 5 386
10VR04 3 81 293 68.8% 481 7 385
10VR07 5 143 293 68.8% 481 12 385
10VR11 7 1/2 227 297 68.8% 487 20 389
10VR15 10 308 293 68.8% 482 27 386
10VR17 15 353 298 68.8% 488 32 391

Low flow, suction and power, per pump

Model Min continuous flow, GPM Preferred range, GPM NPSH required at best efficiency, ft NPSH required at max flow, ft Max brake HP
3VR05 7.5 11-19 6.3 19.1 1.0
3VR08 7.5 11-20 6.4 19.1 1.6
3VR11 7.5 11-19 6.3 19.0 2.2
3VR17 7.5 11-19 6.2 18.7 3.3
6VR03 15.4 23-39 8.9 14.4 0.9
6VR05 15.4 22-39 8.8 14.4 1.5
6VR07 15.4 22-39 8.7 14.3 2.1
6VR11 15.4 22-38 8.6 14.1 3.2
6VR15 15.4 22-38 8.7 16.6 4.3
6VR19 15.4 22-38 8.6 16.3 5.3
6VR23 15.4 23-39 8.9 16.9 6.9
10VR02 33.0 41-71 10.8 29.2 1.5
10VR03 33.0 41-70 10.7 28.9 2.2
10VR04 33.0 41-70 10.6 28.7 2.9
10VR07 33.0 41-70 10.6 28.7 5.0
10VR11 33.0 41-71 10.9 29.3 8.2
10VR15 33.0 41-70 10.6 28.8 10.8
10VR17 33.0 41-71 11.0 29.5 12.7
15VR to 30VR — 19 models, 2-30 HP per pump

Pressure and flow

Model HP 0 GPM (Shut-off) GPM at best efficiency, all 5 Pump efficiency at best efficiency Max GPM, all 5 PSI at max GPM Max GPM, one on standby
15VR01 2 29 431 66.0% 670 7 536
15VR03 5 88 433 66.0% 674 22 539
15VR04 7 1/2 119 437 66.0% 680 30 544
15VR06 10 179 438 66.0% 681 46 545
15VR09 15 269 460 69.8% 701 56 561
15VR12 20 357 458 69.8% 699 74 559
20VR01 2 31 487 66.6% 752 9 602
20VR02 5 63 500 66.6% 773 20 618
20VR03 7 1/2 95 502 66.6% 776 30 621
20VR04 10 128 505 66.6% 781 40 625
20VR07 15 225 524 69.6% 787 73 629
20VR10 20 320 520 69.6% 782 103 625
30VR01 5 48 937 74.0% 1,116 25 893
30VR021A 7 1/2 84 869 72.6% 1,115 41 892
30VR02 10 98 946 74.0% 1,128 52 902
30VR03 15 147 946 74.0% 1,127 79 902
30VR052A 20 219 884 72.9% 1,119 108 895
30VR062A 25 271 904 73.1% 1,132 137 906
30VR072A 30 321 912 73.2% 1,133 164 906

Low flow, suction and power, per pump

Model Min continuous flow, GPM Preferred range, GPM NPSH required at best efficiency, ft NPSH required at max flow, ft Max brake HP
15VR01 44.0 60-103 7.9 21.7 1.6
15VR03 44.0 60-104 8.0 22.0 4.9
15VR04 44.0 61-104 8.1 22.4 6.7
15VR06 44.0 61-105 8.2 22.5 10.2
15VR09 44.0 64-110 8.8 24.9 14.7
15VR12 44.0 64-110 8.7 24.8 19.4
20VR01 52.8 68-117 10.8 20.8 2.1
20VR02 52.8 70-120 11.3 21.9 4.6
20VR03 52.8 70-120 11.4 22.1 7.0
20VR04 52.8 70-121 11.6 22.4 9.5
20VR07 52.8 73-125 12.2 22.6 15.7
20VR10 52.8 72-124 12.0 22.3 22.0
30VR01 123.3 131-223 16.9 28.8 4.8
30VR021A 123.3 123-208 14.2 28.7 8.2
30VR02 123.3 132-225 17.2 29.4 9.9
30VR03 123.3 132-225 17.2 29.3 14.8
30VR052A 123.3 123-212 14.8 28.9 21.3
30VR062A 123.3 126-217 15.5 29.6 27.1
30VR072A 123.3 127-218 15.7 29.7 32.2
45VR to 95VR — 21 models, 7 1/2-60 HP per pump

Pressure and flow

Model HP 0 GPM (Shut-off) GPM at best efficiency, all 5 Pump efficiency at best efficiency Max GPM, all 5 PSI at max GPM Max GPM, one on standby
45VR01 7 1/2 49 1,270 77.5% 1,741 23 1,392
45VR02 15 98 1,277 77.5% 1,751 48 1,400
45VR031A 20 137 1,231 76.5% 1,742 61 1,394
45VR03 25 149 1,289 77.5% 1,768 74 1,414
45VR041A 30 188 1,259 76.7% 1,767 88 1,414
45VR062A 40 279 1,254 76.5% 1,775 128 1,420
65VR011A 7 1/2 39 1,566 76.9% 2,323 14 1,858
65VR022A 15 78 1,575 76.9% 2,337 29 1,869
65VR021A 20 95 1,695 77.2% 2,331 45 1,865
65VR032A 25 136 1,666 77.0% 2,348 60 1,878
65VR031A 30 153 1,750 77.4% 2,353 76 1,882
65VR042A 40 195 1,723 77.2% 2,372 93 1,897
65VR052A 50 252 1,747 77.3% 2,371 124 1,896
65VR051A 60 272 1,807 77.6% 2,386 142 1,908
95VR011A 15 45 2,008 77.9% 3,139 13 2,511
95VR01 20 62 2,188 79.3% 3,127 27 2,501
95VR022A 25 91 2,010 77.9% 3,143 27 2,514
95VR021A 30 108 2,107 78.6% 3,146 42 2,516
95VR032A 40 155 2,086 78.3% 3,161 56 2,529
95VR03 50 189 2,210 79.3% 3,163 85 2,530
95VR042A 60 220 2,129 78.6% 3,180 85 2,544

Low flow, suction and power, per pump

Model Min continuous flow, GPM Preferred range, GPM NPSH required at best efficiency, ft NPSH required at max flow, ft Max brake HP
45VR01 176.1 177-304 18.1 37.0 7.6
45VR02 176.1 178-306 18.3 37.5 15.5
45VR031A 176.1 176-295 17.0 37.1 21.0
45VR03 176.1 180-309 18.6 38.2 23.9
45VR041A 176.1 176-302 17.8 38.2 29.9
45VR062A 176.1 176-301 17.6 38.5 44.4
65VR011A 154.1 219-375 13.6 54.5 7.6
65VR022A 154.1 220-378 13.8 55.1 15.4
65VR021A 154.1 237-406 16.3 54.9 19.3
65VR032A 154.1 233-399 15.6 55.7 27.5
65VR031A 154.1 245-420 17.6 55.9 31.8
65VR042A 154.1 241-413 16.8 56.8 40.6
65VR052A 154.1 244-419 17.4 56.8 52.8
65VR051A 154.1 252-433 19.1 57.5 58.2
95VR011A 242.2 281-482 14.2 51.9 11.8
95VR01 242.2 306-525 16.8 51.5 16.1
95VR022A 242.2 281-482 14.3 52.0 23.8
95VR021A 242.2 295-505 15.5 52.1 28.3
95VR032A 242.2 292-500 15.2 52.6 40.8
95VR03 242.2 309-530 17.1 52.6 50.0
95VR042A 242.2 298-510 15.8 53.2 58.4

Pressure added in PSI. Source: Franklin Electric FE Select performance data sheets for each VR SpecPAK build (60 Hz, full speed), using the points Franklin tabulates: shut-off, minimum continuous stable flow (MCSF), best efficiency and end of curve. Flows are per-pump figures multiplied by the pumps running; head converted at feet = PSI x 2.31 and rounded down. Derived from the single-pump data at 5 times the flow (or 4 times with one on standby); Franklin publishes no 5-pump package table, and the build is confirmed in FE Select with the submittal. Pump efficiency is the pump alone, without motor and drive losses. NPSH required is Franklin's figure with no margin added. Max brake HP is the highest of the tabulated points at full speed, per pump. Preferred range is derived as 70-120% of the best efficiency flow per pump (ANSI/HI 9.6.3), never below the min continuous flow; Franklin plots its own preferred operating region on each submittal curve. The option values round max boost down to 5 PSI and max flow down to 10 GPM; Franklin rates the 2- to 4-pump line to 2,400 GPM, so option values stop there. Full curves are in each build's submittal on the Data Sheet tab.

Drawing from a tank or cistern — nothing arrives with pressure, so the table figure is what the building gets. Fed by a city main — the pumps add on top of the incoming pressure, and the panel holds the setpoint you enter; incoming pressure buys more flow at that setpoint. A hydropneumatic tank on the discharge lets the system sleep at night-time demand.

Low demand — below the min continuous flow column a pump should not run for long; the panel sleeps at no demand and the tank carries the trickle. Best efficiency — size so the pumps on duty spend most of their hours inside the preferred range; that is where energy use, seal and bearing life are best.

Before You Buy — The Limits That Decide the Fit
Peak demand and redundancy Size the one-on-standby column to your peak where the building cannot lose pressure; the all-running column where it can.
System pressure Incoming pressure plus pressure added must stay under the model's max working pressure (230-460 PSI), shown on its package drawing.
Water and room Fluid and ambient to 104°F; NEMA 1 panel for an indoor mechanical room out of direct sunlight.
Suction Flooded or pressurized suction. NPSH available at the inlet must exceed the NPSH required column at your flow, with margin; check it when the pumps draw from a ground-level tank.
Power Voltage is fixed by the build you select. Max brake HP per pump sets the load; panel full-load amps on the submittal size the feeder.
Access and rigging Ships on its own frame by truck; confirm door widths and the path to the room against the submittal drawing.
Ordering Built to order. Quintuplex packages are engineered builds beyond Franklin's standard duplex to quadplex range; Franklin confirms the build, drawing and lead time with the submittal before the order is released.
Installation Notes
  • Fit isolation valves near the package inlet and outlet; they ease startup and keep the discharge line full during service.
  • Pipe each thermal relief valve outlet to a drain; the valves open fully at 110°F to protect pumps running against a closed discharge.
  • Fill the suction header with site water and vent each pump before first start.
  • Set the frame on a level foundation rated for the operating weight; move it only by the fork pockets.

From the VR SpecPAK Owner's Manual (10000007073) and written specification (M5247).

Applications

Domestic water boosting for high-rise residential, hotels, hospitals and office towers; data center domestic and makeup water; campuses and multi-building sites; industrial process water, irrigation and municipal pressure zones.

Materials of Construction
Pump casing, 3VR-20VR 316L stainless steel
Pump casing, 30VR-95VR Cast iron standard; 316 stainless steel option
Impellers and diffusers 316 stainless steel
Shaft seal Cartridge, silicon carbide / carbon / EPDM
Manifolds and end caps 316 stainless steel
Thermal relief valves, gauge internals 316 stainless steel
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet
VR SpecPAK Catalog (M5222)VR SpecPAK Owner’s Manual (10000007073)SpecPAK Solutions Brochure (M5051)Pressure Boosting Comparison Tool (M5237)Start-Up & Commissioning FormSystem Selection White PaperNSF/ANSI 61 Water Quality Approvals4-Pump Reference Submittal 3VR054-Pump Reference Submittal 3VR084-Pump Reference Submittal 3VR114-Pump Reference Submittal 3VR174-Pump Reference Submittal 6VR034-Pump Reference Submittal 6VR054-Pump Reference Submittal 6VR074-Pump Reference Submittal 6VR114-Pump Reference Submittal 6VR154-Pump Reference Submittal 6VR194-Pump Reference Submittal 6VR234-Pump Reference Submittal 10VR024-Pump Reference Submittal 10VR034-Pump Reference Submittal 10VR044-Pump Reference Submittal 10VR074-Pump Reference Submittal 10VR114-Pump Reference Submittal 10VR154-Pump Reference Submittal 10VR174-Pump Reference Submittal 15VR014-Pump Reference Submittal 15VR034-Pump Reference Submittal 15VR044-Pump Reference Submittal 15VR064-Pump Reference Submittal 15VR094-Pump Reference Submittal 15VR124-Pump Reference Submittal 20VR014-Pump Reference Submittal 20VR024-Pump Reference Submittal 20VR034-Pump Reference Submittal 20VR044-Pump Reference Submittal 20VR074-Pump Reference Submittal 20VR104-Pump Reference Submittal 30VR014-Pump Reference Submittal 30VR021A4-Pump Reference Submittal 30VR024-Pump Reference Submittal 30VR034-Pump Reference Submittal 30VR052A4-Pump Reference Submittal 30VR062A4-Pump Reference Submittal 30VR072A4-Pump Reference Submittal 45VR014-Pump Reference Submittal 45VR024-Pump Reference Submittal 45VR031A4-Pump Reference Submittal 45VR034-Pump Reference Submittal 45VR041A4-Pump Reference Submittal 45VR062A4-Pump Reference Submittal 65VR011A4-Pump Reference Submittal 65VR022A4-Pump Reference Submittal 65VR021A4-Pump Reference Submittal 65VR032A4-Pump Reference Submittal 65VR031A4-Pump Reference Submittal 65VR042A4-Pump Reference Submittal 65VR052A4-Pump Reference Submittal 65VR051A4-Pump Reference Submittal 95VR011A4-Pump Reference Submittal 95VR014-Pump Reference Submittal 95VR022A4-Pump Reference Submittal 95VR021A4-Pump Reference Submittal 95VR032A4-Pump Reference Submittal 95VR034-Pump Reference Submittal 95VR042A