Find your horsepower in the row, then read across. Total head is the depth to the pumping water level, plus 2.31 ft for every PSI you want at the tank, plus drop-pipe friction. The two output tables below do that sum for a 30/50 PSI pressure switch.
S3 5 — 5 GPM class, total head in feet
| HP |
0 GPM (Shut-off) |
2 GPM |
6 GPM |
8 GPM |
10 GPM (Max) |
| 0.5 HP |
362 ft |
342 ft |
244 ft |
165 ft |
70 ft |
| 0.75 HP |
440 ft |
422 ft |
302 ft |
208 ft |
90 ft |
| 1 HP |
538 ft |
524 ft |
368 ft |
242 ft |
106 ft |
S3 10 — 10 GPM class, total head in feet
| HP |
0 GPM (Shut-off) |
2 GPM |
8 GPM |
10 GPM |
14 GPM (Max) |
| 0.5 HP |
320 ft |
304 ft |
224 ft |
174 ft |
36 ft |
| 0.75 HP |
420 ft |
394 ft |
290 ft |
230 ft |
50 ft |
| 1 HP |
490 ft |
462 ft |
348 ft |
270 ft |
60 ft |
S3 15 — 15 GPM class, total head in feet
| HP |
0 GPM (Shut-off) |
4 GPM |
10 GPM |
14 GPM |
18 GPM (Max) |
| 0.5 HP |
134 ft |
130 ft |
110 ft |
84 ft |
35 ft |
| 0.75 HP |
260 ft |
250 ft |
212 ft |
154 ft |
52 ft |
| 1 HP |
332 ft |
320 ft |
268 ft |
194 ft |
60 ft |
From DAB’s S3 60 Hz performance table (S3 Technical Sheet, 2024), at the printed flows nearest 20%, 50% and 75% of each class’s last printed flow. 0 GPM is the printed shut-off; the last column is DAB’s last printed point. Drop-pipe friction is not included.
Output in GPM at 30 PSI (switch cut-in), by depth to pumping water
| Model |
20 ft |
40 ft |
60 ft |
80 ft |
100 ft |
150 ft |
200 ft |
| 5 GPM · 0.5 HP |
9.5 |
9 |
8.5 |
8 |
7.5 |
6.5 |
5 |
| 5 GPM · 0.75 HP |
— |
9.5 |
9 |
9 |
8.5 |
7.5 |
6.5 |
| 5 GPM · 1 HP |
— |
9.5 |
9.5 |
9 |
9 |
8 |
7.5 |
| 10 GPM · 0.5 HP |
12.5 |
12 |
11 |
10.5 |
10 |
8 |
5 |
| 10 GPM · 0.75 HP |
13 |
12.5 |
12 |
12 |
11.5 |
10 |
8.5 |
| 10 GPM · 1 HP |
13.5 |
13 |
12.5 |
12.5 |
12 |
11 |
10 |
| 15 GPM · 0.5 HP |
13 |
10 |
4 |
— |
— |
— |
— |
| 15 GPM · 0.75 HP |
16.5 |
16 |
15 |
14 |
13 |
9 |
— |
| 15 GPM · 1 HP |
17 |
16.5 |
16 |
15.5 |
14.5 |
12.5 |
9.5 |
Output in GPM at 50 PSI (switch cut-out), by depth to pumping water
| Model |
20 ft |
40 ft |
60 ft |
80 ft |
100 ft |
150 ft |
200 ft |
| 5 GPM · 0.5 HP |
8.5 |
8 |
7.5 |
7 |
6.5 |
5 |
3 |
| 5 GPM · 0.75 HP |
9 |
8.5 |
8.5 |
8 |
7.5 |
6.5 |
5.5 |
| 5 GPM · 1 HP |
9.5 |
9 |
8.5 |
8.5 |
8 |
7.5 |
6.5 |
| 10 GPM · 0.5 HP |
11 |
10.5 |
9.5 |
9 |
8 |
5.5 |
— |
| 10 GPM · 0.75 HP |
12 |
11.5 |
11 |
10.5 |
10 |
8.5 |
6.5 |
| 10 GPM · 1 HP |
12.5 |
12 |
12 |
11.5 |
11 |
10 |
8.5 |
| 15 GPM · 0.5 HP |
— |
— |
— |
— |
— |
— |
— |
| 15 GPM · 0.75 HP |
14.5 |
13.5 |
12.5 |
11 |
9.5 |
— |
— |
| 15 GPM · 1 HP |
16 |
15 |
14.5 |
13.5 |
12.5 |
10 |
4.5 |
Calculated from DAB’s head-at-flow table (S3 Technical Sheet, 2024); DAB publishes no output table for this pump. Each cell is the flow where DAB’s curve meets the depth to pumping water plus the pressure (30 PSI = 69 ft, 50 PSI = 116 ft), interpolated between DAB’s printed points and rounded down to 0.5 GPM. — = beyond DAB’s printed range or under 1 GPM. Pipe friction is not included.
Enter your water level, pipe run and pressure. The calculator shows which DAB pumps cover the duty, with the headroom on each.