Menu
Product variant with selected options does not exist!
UNILIFT KP is designed for liquid transfer and drainage of clean or slightly dirty wastewater with the pump completely or partly submerged in the liquid. It suits drainage of flooded cellars or buildings, pumping of domestic wastewater without toilet waste, emptying of pools, tanks and vessels, and pumping within agriculture, the dairy industry, horticulture and the process industry.
The pump is a single-stage, submersible, stainless-steel drainage pump in a robust design with an upward-pointing discharge port placed on top of the pump. Water enters through the holes of the suction strainer, which prevents the passage of large solids. The sturdy impeller has single-curved vanes with bevelled front edges that prevent fibres from jamming the impeller. The guide vanes in the pump housing guide the liquid, lifting sand grains into the liquid flow and so preventing blocking by sand.
The pump sleeve is made in one piece. The mains cable enters through a vulcanized and water-tight plug, secured to the socket of the hermetically sealed stator housing. The motor is a single-phase asynchronous canned motor with a liquid-filled rotor chamber and water-lubricated bearings, cooled by the pumped liquid around the motor. It incorporates automatic overload protection: on overload the motor stops and, once cooled, restarts automatically.
Maximum particle size is 0.4 in. Liquid temperature range is 32 °F to 122 °F, with 158 °F permitted for periods not exceeding two minutes at intervals of at least 30 minutes. Maximum installation depth is 30 ft below liquid level. The pumps are suitable for temporary as well as permanent free-standing installation and are not designed for continuous operation.
Find your vertical lift down the left. The figure is the maximum combined vertical plus horizontal Schedule 40 PVC pipe run Grundfos allows for that model at that lift.
| Vertical lift | KP 150 | KP 250 | KP 350 |
|---|---|---|---|
| 4 ft | 400 ft | 775 ft | 950 ft |
| 8 ft | 250 ft | 625 ft | 800 ft |
| 12 ft | 100 ft | 450 ft | 625 ft |
| 14 ft | 30 ft | — | — |
| 16 ft | — | 300 ft | 500 ft |
| 20 ft | — | 150 ft | 350 ft |
| 22 ft | — | 75 ft | — |
| 24 ft | — | — | 175 ft |
| 26 ft | — | — | 100 ft |
Grundfos publishes this overview as a guide only. If a non-return valve is fitted, deduct approximately 0.6 ft of head from the vertical pipe length. Measure the vertical height of the discharge pipe from the pump stop level. A dash means Grundfos publishes no figure for that model at that lift.
Flow velocity through the outlet pipe must be at least 2.3 ft/s to keep the line self-cleaning. A Schedule 40 PVC outlet pipe with a 1.38 in inner diameter needs roughly 12 gpm to achieve it. Across the KP range Grundfos publishes a maximum flow of 65 GPM and a maximum head of 32 ft; both belong to KP 350 and are range ceilings, not a single duty point.
| Model | HP | Voltage & Phase | Level Control | Part No. |
|---|---|---|---|---|
| UNILIFT KP 150 M-1 | 1/4 | 115V 1Ph | Manual — no float switch | 011DC201 |
| UNILIFT KP 250 M-1 | 1/3 | 115V 1Ph | Manual — no float switch | 012DC201 |
| UNILIFT KP 350 M-1 | 1/2 | 115V 1Ph | Manual — no float switch | 013DC201 |
Where two voltages are shown, the first is the factory wiring setting. Voltage is changed on the motor terminal board, never at the pressure switch. All models are single phase unless the table states 3Ph.
| Specification | Value |
|---|---|
| Pump type | Single-stage submersible drainage pump, free-standing installation |
| Maximum particle size | 0.4 in (10 mm) |
| Impeller | Semi-open, 2-pole |
| Liquid temperature | 32 °F to 122 °F (158 °F for up to 2 minutes at intervals of at least 30 minutes) |
| pH range | 4 to 9 |
| Maximum liquid density | 146.88 oz/gal |
| Maximum installation depth | 30 ft below liquid level |
| Discharge connection | Rp 1-1/4 in (1.25 in NPT), vertical, top of pump |
| Enclosure class | IP68 |
| Insulation class | F |
| Motor | Single-phase asynchronous canned motor, liquid-filled rotor chamber, water-lubricated bearings |
| Motor protection | Automatic thermal overload with auto-restart |
| Cable | 25 ft, 16 AWG 3/C SJOW 90C, NEMA 5 plug |
| Approvals | CSA C/US |
| Model | P1 [hp] | In [A] | I start [A] | Weight [lbs] | H [in] | B1 [in] | B2 [in] |
|---|---|---|---|---|---|---|---|
| KP 150 | 0.353 | 2.9 | 8.7 | 14.33 | 8.86 | 5.87 | 1.22 |
| KP 250 | 0.569 | 4.9 | 14.5 | 15.43 | 8.86 | 5.87 | 1.22 |
| KP 350 | 0.748 | 7.5 | 21.4 | 17.64 | 9.25 | 5.87 | 1.22 |
P1 is motor input power from the Grundfos technical data table; the HP figure in the models table is the nominal rating. Weights are pump weights; shipping weights differ. Space required corresponds to the physical dimensions of the pump.
| Component | Material | DIN W.-Nr. | AISI |
|---|---|---|---|
| Pump sleeve | Stainless steel | 1.4301 | 304 |
| Pump housing | Stainless steel | 1.4301 | 304 |
| Suction strainer | Stainless steel | 1.4301 | 304 |
| Impeller | Stainless steel | 1.4301 | 304 |
| Shaft | Stainless steel | 1.4057 | 431 |
| Stator housing | Stainless steel | 1.4301 | 304 |
| Guide vanes | Stainless steel | 1.4301 | 304 |
| Bearings | Carbon | — | — |
| O-rings, seal rings | NBR | — | — |
| Cable | 16 AWG 3/C SJOW 90C | — | — |
All three models listed are the manual (M) version and are supplied without a float switch. For automatic on/off the pump can be fitted with a float switch, or connected to a separate level switch and control box. Each model ships with 25 ft of cable and a NEMA 5 plug for 115 V service.
Order by part number: KP 150 — 011DC201; KP 250 — 012DC201; KP 350 — 013DC201.