Grundfos CRN 215 Vertical Multistage Pump End, Motor Not Included

HP - NEMA Frame: 50 HP - 326TSC
Shaft Seal: HQQE - EPDM
Connection - Model - Max: ANSI - CRN 215-1-1 - 83 PSI Max, 1479 GPM Max

Product variant with selected options does not exist!

Price
$21,568.42
SKU: 99400505
Weight : 852.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
GRUNDFOS · VERTICAL MULTISTAGE PUMP END
CRN 215 Pump End
Vertical multistage pump end in 316 stainless steel, motor not included. 16 models from CRN 215-1-1 to CRN 215-5-1 for 50 to 300 HP NEMA motors (326TSC to 449TSD frames), 8 in ANSI flanged or 8 in Victaulic-type ports, HQQE or HQQV cartridge shaft seal.
193-1,208 ft (83-522 PSI) Max Head · 1,479 GPM Max
Fits 50-300 HP NEMA Motors, Frame 326TSC to 449TSD
8 in ANSI or 8 in Victaulic Ports
In-Line Suction and Discharge
232-580 PSI Max Operating Pressure
556-858 lb Weight
Overview

The CRN 215 pump end is the hydraulic part of a Grundfos CRN 215 vertical multistage pump, supplied without a motor: order it to rebuild an existing CRN 215, to change the number of stages for a new duty, or to build a pump on a motor you already have. Every part in contact with the liquid is stainless steel (EN 1.4401, AISI 316). Suction and discharge sit on the same level, so it drops into a straight pipe run. The CRN 215 is rated at 1140 GPM (Grundfos rated flow); size it from the performance table below rather than from the model number.

  • 16 models, CRN 215-1-1 to CRN 215-5-1, each built for a NEMA C-face motor of 50 to 300 HP (motor table below)
  • 8 in ANSI flanges, 150 lb (CRN 215-1-1 to CRN 215-2) or 300 lb (CRN 215-3-3 to CRN 215-5-1), with a cast iron flange and base plate that do not touch the liquid (CRN 215-1-1 to CRN 215-5-1); or 8 in Victaulic-type grooved ends, with a cast iron base plate that does not touch the liquid (CRN 215-1-1 to CRN 215-5-1)
  • HQQE (EPDM) or HQQV (FKM) cartridge shaft seal with silicon-carbide faces
  • Maximum operating pressure: ANSI versions 232-580 PSI; Victaulic versions 363-580 PSI (by model)
What Ships and What It Needs to Run

Included: the CRN 215 pump end and the motor coupling (Grundfos price list).

Motor required, ordered separately. A NEMA C-face motor at the horsepower and frame shown for your model in the motor table under Models & Performance (50 to 300 HP), with the starter or drive that motor needs. Grundfos specifies a smooth-shaft motor, or a keyed shaft with a half key, for balanced running (price list).

ANSI companion flanges or Victaulic couplings required, ordered separately. Grundfos supplies the companion connections as a separate 8 in set (Grundfos price list).

Suction and discharge piping, valves and controls: sized to your system and ordered separately.

Genuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Warranty: 24 months from date of installation, but not more than 30 months from date of manufacture (Grundfos limited warranty). Grundfos repairs or replaces its own product; costs of removal, installation and transportation are not covered, and products sold but not manufactured by Grundfos carry their own manufacturer’s warranty.
Specifications
Specification Value
Product Pump end only: hydraulic assembly and motor coupling, motor not included
Rated flow at 60 Hz 1140 GPM (Grundfos rated flow)
Motor required NEMA C-face, 50 to 300 HP; frames 326TSC, 365TSC, 405TSD, 444TSD, 445TSD, 447TSD, 449TSD (by model, see motor table)
Suction and discharge ports In-line; 8 in
Connections 8 in ANSI flanges, 150 lb (CRN 215-1-1 to CRN 215-2) or 300 lb (CRN 215-3-3 to CRN 215-5-1), with a cast iron flange and base plate that do not touch the liquid; 8 in Victaulic-type grooved ends
Maximum operating pressure ANSI versions 232-580 PSI; Victaulic versions 363-580 PSI (by model)
Liquid temperature Up to 248 °F with HQQE; up to 194 °F with HQQV
Shaft seal HQQE (EPDM) or HQQV (FKM) cartridge seal, SiC/SiC faces
Pump orientation Vertical
Frequency 60 Hz
App None: a mechanical pump end with no electronics
Models & Performance — Will It Do What You Need?

Find the pressure you need at your flow and pick the first model that reaches it. Pressure at flow in PSI, one row per model.

CRN 215-1-1 to CRN 215-3 · 9 models
Model 0 GPM (Shut-off) 295 GPM 738 GPM 1,106 GPM 1,475 GPM
CRN 215-1-1 83 83 76 59 31
CRN 215-1 111 105 96 81 56
CRN 215-2-2 170 165 152 117 60
CRN 215-2-1 195 189 174 143 90
CRN 215-2 220 214 198 169 119
CRN 215-3-3 255 249 230 180 94
CRN 215-3-2 279 272 253 205 123
CRN 215-3-1 305 298 277 233 155
CRN 215-3 330 323 301 260 185
CRN 215-4-3 to CRN 215-5-1 · 7 models
Model 0 GPM (Shut-off) 295 GPM 738 GPM 1,106 GPM 1,475 GPM
CRN 215-4-3 363 355 331 266 157
CRN 215-4-2 389 381 355 294 188
CRN 215-4-1 414 407 379 321 218
CRN 215-4 438 432 403 348 248
CRN 215-5-3 472 464 432 355 220
CRN 215-5-2 497 490 457 383 251
CRN 215-5-1 522 515 481 409 281

Pressure the pump end develops at each flow, in PSI, rounded down (feet = PSI × 2.31), with the motor shown in the motor table. Shut-off is Grundfos’s published maximum head for each model. Flow columns are digitized from the published 60 Hz curve in the CR, CRN 95-255 Data Booklet (60 Hz, 2026), p. 43 (water at 68 °F), and rounded down, at about 20%, 50% and 75% of 1,475 GPM, the last regular flow every curve in this listing reaches; the curves end at 1,479.5 GPM. Full curves are in the product images.

Motor each model needs (Grundfos price list and catalog; the motor is ordered separately):

CRN 215-1-1 to CRN 215-5-1 · 16 models · 50 to 300 HP
Model Motor HP NEMA frame
CRN 215-1-1 50 326TSC
CRN 215-1 75 365TSC
CRN 215-2-2 100 405TSD
CRN 215-2-1 125 444TSD
CRN 215-2 125 444TSD
CRN 215-3-3 150 445TSD
CRN 215-3-2 150 445TSD
CRN 215-3-1 200 447TSD
CRN 215-3 200 447TSD
CRN 215-4-3 200 447TSD
CRN 215-4-2 250 449TSD
CRN 215-4-1 250 449TSD
CRN 215-4 250 449TSD
CRN 215-5-3 250 449TSD
CRN 215-5-2 300 449TSD
CRN 215-5-1 300 449TSD
Before You Buy — The Limits That Decide the Fit
Check What decides the fit
Motor Order a NEMA C-face motor at the HP and frame Grundfos lists for your model in the motor table under Models & Performance. Use a smooth-shaft motor or a keyed shaft with a half key (Grundfos price list).
Duty point The model’s pressure at your flow must cover the system’s total head; the shut-off column is Grundfos’s published maximum head, the most the model can make.
Working pressure Inlet pressure plus the pressure the pump adds must stay within the maximum operating pressure: ANSI versions 232-580 PSI; Victaulic versions 363-580 PSI (by model).
Liquid temperature Up to 248 °F with HQQE; up to 194 °F with HQQV.
Connections ANSI companion flanges or Victaulic couplings (8 in) ordered separately. Match the connection to the existing pipework.
Shaft seal HQQE has EPDM rubber parts and HQQV has FKM; choose the rubber that suits the pumped liquid.
Applications

HVAC heating and air conditioning, district heating and cooling, plumbing pressure boosting, industrial water supply and transfer, process liquids, wash and clean, water treatment, irrigation and ground water transfer (Grundfos CR range applications).

Materials of Construction
Component Material
All wetted parts Stainless steel EN 1.4401 (AISI 316)
Base plate; flange (ANSI versions) Cast iron, not in contact with the pumped liquid
Shaft seal faces Silicon carbide / silicon carbide (HQQ cartridge seal)
Seal and gasket rubber EPDM (HQQE) or FKM (HQQV)
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.