Grundfos CRIE 10 Variable-Speed Pump, 2 in FlexiClamp, 3600 rpm

HP - Voltage: 1 HP - 200-240V 1Ph
Model: CRIE 10-1
Sensor: With Sensor

Product variant with selected options does not exist!

Price
$4,526
SKU: 99340940
Weight : 97.9999 lb
Free Shipping $499 or more
Need it fast? Call for same-day shipping options: 281.664.8000
Description
GRUNDFOS · VARIABLE-SPEED VERTICAL MULTISTAGE PUMP
CRIE 10 — 2 in FlexiClamp, 3600 rpm
All AISI 304 stainless vertical multistage pump with an integrated MLE variable-speed motor. 45.9-53.7 GPM rated flow, 6 models from CRIE 10-1 to CRIE 10-10, 1 to 7-1/2 HP, HQQE cartridge seal, with or without a factory pressure sensor.
45.9-53.7 GPM Rated Flow
38-380 ft Rated Head
1 to 7-1/2 HP
Variable Speed
232 psi Max
Overview

CRIE 10 is the all-stainless CRI platform with the drive built into the motor. The MLE motor carries its own frequency converter and a graphical control panel, so the pump varies its own speed to hold a setpoint instead of running flat out and throttling. There is no separate VFD to buy, mount, wire or commission.

Hydraulically it is a vertical multistage pump with suction and discharge on the same centreline, so it drops into a straight pipe run. The whole liquid path is AISI 304 stainless — pump head, base, chambers and impellers — which is what separates CRIE from CRE, where the head and base are cast iron.

This listing is the 3600 rpm, 2 in FlexiClamp build. Grundfos publishes the 3600 rpm and 4000 rpm variants as separate part numbers with different duty points, so they are listed separately rather than mixed. 6 models cover 38 ft to 380 ft of rated head on 1 to 7-1/2 HP motors, with 2 to 10 stages.

Speed is the whole point. The motor runs anywhere from 360 rpm up to its rated speed, so one pump covers a wide duty band and holds constant pressure as demand changes. That also means the published duty points below are full-speed figures — at part load the pump sits lower on its curve and draws proportionally less power.

Genuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Performance — Will It Do What You Need?

A pump curve plots what the pump adds, not what comes out of the tap. The impeller does not know what pressure is on its inlet. Every figure below is pressure the pump adds to whatever already arrives — it is not a discharge pressure and it is not the controller setpoint.

Model HP Voltage & Phase Rated flow - GPM Rated head - ft Max head - ft Rated speed - rpm Max pressure - psi
CRIE 10-1 1 200-240V 1Ph 45.9 37.9 46.6 3458 232
CRIE 10-1 1 440-480V 3Ph 46.6 39 47.2 3510 232
CRIE 10-1 1-1/2 200-240V 3Ph 47 39.7 47.6 3539 232
CRIE 10-2 1-1/2 200-240V 3Ph 48.9 77.2 95.5 3470 232
CRIE 10-2 1-1/2 440-480V 3Ph 49 77.7 95.5 3482 232
CRIE 10-2 2 200-240V 1Ph 48.7 76.2 98.8 3459 232
CRIE 10-4 3 200-240V 3Ph 52.4 150.1 191.9 3473 232
CRIE 10-4 3 440-480V 3Ph 52.6 151 191.9 3484 232
CRIE 10-6 5 200-240V 3Ph 53.6 229.1 289.4 3502 232
CRIE 10-6 5 440-480V 3Ph 52.4 219.1 284.4 3425 232
CRIE 10-8 7-1/2 200-240V 3Ph 53.6 306.2 385.2 3504 232
CRIE 10-8 7-1/2 440-480V 3Ph 53.7 306.6 385.5 3507 232
CRIE 10-10 7-1/2 200-240V 3Ph 53.1 376 479.7 3467 232
CRIE 10-10 7-1/2 440-480V 3Ph 53.3 379.6 480 3485 232

Grundfos published figures at the rated duty point, 60 Hz, at full speed. The duty point depends on the motor, not only on the stage count — the same model on a different HP or voltage reaches a different speed and therefore a different head, which is why this table lists one row per motor rather than one per model. Rated head is the duty point at rated flow; max head is the shut-off ceiling at zero flow, not a working point. Rated speed is the published figure and sits under the 3600 rpm nominal. Boost in psi equals head in feet multiplied by 0.433. For a duty between two models, ask us to size it against the published curve.

Drawing from a tank, cistern or well. Nothing arrives with pressure, so what the pump adds is what you get. Read the table straight through: a CRIE 10-4 on a 3 HP, 440-480V 3Ph motor gives you about 65 psi at 52.6 GPM.

Fed by a city main. The pump adds on top of what already arrives, and the controller holds the total. On a 40 psi main asking for 105 psi at the fixture, the pump only has to add 65 — and because it is variable speed it will do exactly that and no more. Incoming pressure buys you more flow, not more pressure.

With Sensor or Without — Which Do You Need?

With sensor. The pump ships with a factory pressure sensor and the wiring to it. Out of the box it holds a constant discharge pressure: set the pressure you want on the control panel and the pump varies its speed to maintain it. This is the version to order unless you already know otherwise.

Without sensor. The pump is the same machine with the same drive and panel, but no pressure sensor is supplied. It cannot hold constant pressure until a sensor is connected, or it is driven by an external signal or a building management system. Order this version only when the sensor already exists, is supplied by others, or the pump runs in constant-speed or externally-controlled mode.

The sensor range against each part number is the sensor’s measuring span — on this listing, 0-87 psi to 0-362 psi depending on model. That span is the ceiling on what the controller can be told to hold; it is not a claim about what the pump can produce. Read it together with the rated head table and the maximum operating pressure.

Models, Voltage & Sensor
Model HP Voltage & Phase Sensor Part No.
CRIE 10-1 1 200-240V 1Ph With sensor, 0-87 psi 99340940
CRIE 10-1 1 200-240V 1Ph Without sensor 99340942
CRIE 10-1 1 440-480V 3Ph With sensor, 0-87 psi 99340971
CRIE 10-1 1 440-480V 3Ph Without sensor 99340974
CRIE 10-1 1-1/2 200-240V 3Ph With sensor, 0-87 psi 99392019
CRIE 10-1 1-1/2 200-240V 3Ph Without sensor 99391964
CRIE 10-2 1-1/2 440-480V 3Ph With sensor, 0-145 psi 99340972
CRIE 10-2 1-1/2 200-240V 3Ph With sensor, 0-145 psi 99392020
CRIE 10-2 1-1/2 440-480V 3Ph Without sensor 99340975
CRIE 10-2 1-1/2 200-240V 3Ph Without sensor 99391965
CRIE 10-2 2 200-240V 1Ph With sensor, 0-145 psi 99340941
CRIE 10-2 2 200-240V 1Ph Without sensor 99340943
CRIE 10-4 3 440-480V 3Ph With sensor, 0-145 psi 99340973
CRIE 10-4 3 200-240V 3Ph With sensor, 0-145 psi 99392022
CRIE 10-4 3 440-480V 3Ph Without sensor 99340977
CRIE 10-4 3 200-240V 3Ph Without sensor 99391966
CRIE 10-6 5 440-480V 3Ph With sensor, 0-232 psi 99076176
CRIE 10-6 5 200-240V 3Ph With sensor, 0-232 psi 99392023
CRIE 10-6 5 440-480V 3Ph Without sensor 99076159
CRIE 10-6 5 200-240V 3Ph Without sensor 99391967
CRIE 10-8 7-1/2 440-480V 3Ph With sensor, 0-232 psi 99076177
CRIE 10-8 7-1/2 200-240V 3Ph With sensor, 0-232 psi 99392024
CRIE 10-8 7-1/2 440-480V 3Ph Without sensor 99076160
CRIE 10-8 7-1/2 200-240V 3Ph Without sensor 99391968
CRIE 10-10 7-1/2 440-480V 3Ph With sensor, 0-362 psi 99076178
CRIE 10-10 7-1/2 200-240V 3Ph With sensor, 0-362 psi 99392025
CRIE 10-10 7-1/2 440-480V 3Ph Without sensor 99076161
CRIE 10-10 7-1/2 200-240V 3Ph Without sensor 99391970

Voltage and phase are fixed per part number on an MLE motor — a single-phase unit cannot be rewired for three-phase supply. Confirm the service before ordering.

Key Features
  • All AISI 304 stainless liquid path — pump head, base, chambers and impellers, with no cast iron anywhere the water touches.
  • Frequency converter built into the motor — no separate drive to buy, mount, wire or commission, and no drive panel to find space for.
  • 360-4000 rpm speed range — the pump throttles itself by slowing down rather than by closing a valve, which is where the energy saving comes from.
  • Graphical control panel with the FM300 Advanced and FM310 Advanced function module — setpoint, control mode and alarms are set on the pump itself.
  • IE5 motor efficiency class, enclosure IP55, with built-in electronic motor protection.
  • In-line ports — suction and discharge on the same level, so the pump installs in a straight run without an elbow or offset.
  • Cartridge shaft seal — HQQE, silicon-carbide faces, replaced as a complete unit without setting faces by hand.
  • NSF/ANSI 61 certified for drinking water contact.
  • 2 in FlexiClamp connection — Grundfos type FlexiClamp, rated PN 25.
Specifications
Specification Value
Rated flow at 60 Hz 45.9-53.7 GPM
Rated head range 38 to 380 ft
Maximum head at shut-off 480 ft on the tallest stack
Rated speed 3425-3539 rpm (3600 rpm nominal)
Speed range 360-4000 rpm
Stages 2 to 10 stages
Motor power range 1 to 7-1/2 HP
Voltage and phase 200-240V 1Ph; 200-240V 3Ph; 440-480V 3Ph
Motor Grundfos MLE, integrated frequency converter, IE5, IP55
Control Graphical panel, FM300 Advanced and FM310 Advanced
Frequency 60 Hz
Suction and discharge port 2 in
Connection FlexiClamp — 2 in FlexiClamp, rated PN 25
Maximum operating pressure 232 psi
Maximum settable pressure Sensor span 0-87 psi to 0-362 psi depending on model — see the limits table, the pump rating is the other half of this
Liquid temperature range -4 to 248 °F (-20 to 120 °C)
Maximum ambient temperature 104 °F or 122 °F depending on the motor
Shaft seal HQQE — silicon-carbide faces, EPDM rubber
Pumped liquid Clean, thin, non-explosive liquids without solid particles or fibres
Pump orientation Vertical
Drinking water approval NSF/ANSI 61
Curve tolerance ISO9906:2012 3B
Materials
Component Material
Pump head and base Stainless steel
Chambers and impellers Stainless steel, EN 1.4301 (AISI 304)
Shaft seal faces Silicon carbide / silicon carbide
Seal and gasket rubber EPDM
Bearing Silicon carbide (SiC)
Applications
  • Constant-pressure boosting where iron pick-up into the water is unacceptable
  • Potable water boosting in commercial buildings and multi-unit residential
  • Water treatment, filtration and reverse osmosis feed
  • Boiler feed and condensate transfer
  • Food, beverage and light process duty on clean, low-chloride liquids
  • Retrofits replacing a fixed-speed pump plus external VFD with one machine
Before You Buy — The Limits That Decide the Fit

The curve is one check of several, and rarely the one that fails.

Limit Why it decides the fit
Maximum settable pressure The sensor span is 0-87 psi to 0-362 psi depending on model, and that is the highest pressure the controller can be told to hold. The binding limit is whichever is lower — the sensor span, or what the pump can produce at your flow on top of your inlet pressure. A sensor rated above the pump’s body rating does not raise what the pump can deliver.
Maximum operating pressure 232 psi. This is inlet pressure plus what the pump adds. A strong city main can push a well-matched pump past its casing rating.
Motor choice changes the duty On this range the same model on a different HP or voltage reaches a different speed and therefore a different head. Read the performance table by the row that matches the part number, not by the model alone.
Suction lift A vertical multistage pump is not self-priming and will not pull a lift. It needs flooded suction or a positive inlet.
Power 200-240V 1Ph; 200-240V 3Ph; 440-480V 3Ph. Voltage and phase are fixed per part number on an MLE motor — this is the commonest cause of a redone quote.
Sensor A without-sensor unit cannot hold constant pressure until a sensor or an external signal is connected.
Liquid temperature -4 to 248 °F (-20 to 120 °C), with a maximum ambient of 104 °F or 122 °F depending on the motor.
Chlorides AISI 304 has no molybdenum. Softened, brackish, coastal or chloride-bearing water calls for the 316 equivalent, CRNE, not this range.
Pairing A single CRIE runs on its own. Multi-pump staging is a Grundfos Hydro MPC or Hydro Multi-E system built around these pumps, specified as a set — ask us if that is what you need.
Sizing It So It Lasts

Best operating range. Grundfos does not publish an efficiency curve for this range in the product data, and a range cannot honestly be derived from a single published duty point, so we do not print one here. Send us the duty and we will read it off the curve for the exact model.

This is where the pump turns the most electricity into water pressure. Ask for more flow than it can deliver at your setting and it runs at full speed continuously, which is where motors and seals wear out. Sizing a booster to the building rather than to the headline numbers is what makes it last.

What Is Supplied

Each part number is a complete pump: pump end, MLE variable-speed motor with its built-in frequency converter and graphical control panel, coupling, coupling guard and HQQE cartridge shaft seal, factory assembled and tested.

The pressure sensor is supplied only on the with-sensor part numbers. Check the Sensor column above against the part number you are ordering.

Grundfos publishes this connection as FlexiClamp; the clamp fittings that mate to it are ordered separately unless your quotation says otherwise — ask us to confirm against the part number. Expansion tanks, isolation valves, external sensors, foundation bolts and building-management interfaces are not included.

Ordering Information

Select the HP and voltage, then the model, then whether you want the factory pressure sensor. Each combination is a distinct Grundfos part number, listed in the table above and shown in the SKU of the selected variant.

The picker shows only the combinations Grundfos publishes for the 2 in FlexiClamp, 3600 rpm build.

Before You OrderConfirm the duty against the rated head table, reading the row that matches your HP and voltage and remembering that those figures are what the pump adds at full speed. Check voltage and phase against your service — they are fixed per part number. Confirm the sensor range covers the pressure you intend to hold, and that inlet pressure plus added pressure stays inside the body rating. This pump needs flooded suction.
For engineering-led sizing and selection support or a factory submittal package, call 1-888.510.4036 or email sales@watermainsupply.com.
Data Sheet

Dimensional drawings, curve pages and a factory submittal package are available on request — email sales@watermainsupply.com with the part number.

You May Also Like