GRUNDFOS · VERTICAL MULTISTAGE CENTRIFUGAL PUMP
CRI 10, ODP Motor
All-stainless vertical multistage centrifugal pump. 53.3 GPM rated flow at 60 Hz, 3 models from CRI 10-14 to CRI 10-17, 15 HP, ODP motor, HQQE or HQQV cartridge seal.
53.3 GPM Rated Flow
512-638 ft Rated Head
15 HP
NSF/ANSI 61
All 304 Stainless
Overview
Vertical, multistage centrifugal pump with suction and discharge ports on the same level. CRI is the all-stainless version of the CR platform: the pump head and base are stainless steel rather than cast iron, and every wetted part is AISI 304. Because the ports share a centreline, the pump installs in a straight pipe run without an offset.
The CRI 10 frame is rated at 53.3 GPM. The family number is Grundfos’s nominal duty in cubic metres per hour, not a GPM figure — size the pump from the rated head table below, not from the model number.
3 models are offered, from CRI 10-14 to CRI 10-17, covering 15 HP on NEMA 254TC C-face open drip-proof (ODP) motors. Adding stages raises head at the same flow without changing the footprint. Connections are 2 in ANSI 300 lb flanged, rated 232 psi maximum operating pressure.
CRI against CR. The hydraulics are shared, so a CRI 10-16 and the matching CR model have the same rated duty point. The difference is the head and base material: choose CRI where a cast iron pump head is a problem — deionised water, wash-down duty, or anywhere iron pick-up matters.
Genuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Performance — Will It Do What You Need?
Find the head you need in feet and pick the model that meets it at 53.3 GPM. Rated head is the duty point at rated flow; max head is the shut-off ceiling at zero flow, not a working point.
| Model |
HP |
Rated flow - GPM |
Rated head - ft |
Max head - ft |
| CRI 10-14 |
15 |
53.3 |
512.5 |
669.3 |
| CRI 10-16 |
15 |
53.3 |
603.7 |
771 |
| CRI 10-17 |
15 |
53.3 |
638.2 |
817 |
Figures are Grundfos published data for 60 Hz at the rated duty point. For a duty between two models, or for flows away from 53.3 GPM, ask us to size it against the published curve.
Models, Voltage & Phase
| Model |
HP |
Voltage & Phase |
Connection & Seal |
Part No. |
| CRI 10-14 |
15 |
208-230/460V 3Ph |
ANSI Flanged - HQQE |
99917315 |
| CRI 10-14 |
15 |
208-230/460V 3Ph |
ANSI Flanged - HQQV |
99917318 |
| CRI 10-16 |
15 |
208-230/460V 3Ph |
ANSI Flanged - HQQE |
99917316 |
| CRI 10-16 |
15 |
208-230/460V 3Ph |
ANSI Flanged - HQQV |
99917319 |
| CRI 10-17 |
15 |
208-230/460V 3Ph |
ANSI Flanged - HQQE |
99917317 |
| CRI 10-17 |
15 |
208-230/460V 3Ph |
ANSI Flanged - HQQV |
99917320 |
Where two voltages are shown, the first is the factory wiring setting. Voltage is changed on the motor terminal board, never at the pressure switch. All models are single phase unless the table states 3Ph.
Key Features
-
All-stainless construction — pump head, base, chambers, impellers, shaft and sleeves in AISI 304. No cast iron in the wetted path at all.
-
In-line ports — suction and discharge on the same level, so the pump installs in a straight run without an elbow or offset.
-
Cartridge shaft seal — replaced as a complete unit without setting the seal by hand and without special tools.
-
Silicon-carbide seal faces — SiC against SiC on both faces in every seal option listed here.
-
NSF/ANSI 61 certified for drinking water contact.
-
Open drip-proof (ODP) NEMA C-face motor — 254TC frames across this range, 60 Hz.
-
Connection — 2 in ANSI 300 lb flanged, rated 232 psi maximum operating pressure.
Shaft Seal Options
-
HQQE — EPDM. Silicon-carbide faces with an EPDM O-ring, rated −4 °F to 248 °F. The standard water seal: potable water, hot water and glycol. Not for mineral oils.
-
HQQV — FKM (Viton). Silicon-carbide faces with an FKM O-ring, rated −4 °F to 194 °F. For mineral oils, fuels and liquids that attack EPDM.
In the Grundfos type key the final letter is the rubber: E = EPDM, V = FKM. Both options use silicon-carbide faces (QQ) and the same cartridge format.
Specifications
| Specification |
Value |
| Rated flow at 60 Hz |
53.3 GPM |
| Rated head range |
512.5 to 638.2 ft |
| Motor power range |
15 HP |
| Motor enclosure |
Open drip-proof (ODP), NEMA C-face |
| NEMA frames |
254TC |
| Frequency |
60 Hz |
| Suction and discharge port |
2 in |
| Connection |
2 in ANSI 300 lb flanged, rated 232 psi maximum operating pressure |
| Maximum operating pressure |
232 psi |
| Liquid temperature range |
−4 °F to 248 °F with HQQE; −4 °F to 194 °F with HQQV |
| Maximum ambient temperature |
104 °F |
| Pumped liquid |
Clean, thin, non-aggressive, non-explosive liquids without solid particles or fibres |
| Pump orientation |
Vertical |
| Drinking water approval |
NSF/ANSI 61 |
| Curve tolerance |
ISO 9906:2012 3B |
Materials
| Component |
Material |
| Pump head and base |
Stainless steel, EN 1.4301 (AISI 304) |
| Chambers and impellers |
Stainless steel, EN 1.4301 (AISI 304) |
| Shaft and sleeves |
Stainless steel, EN 1.4301 (AISI 304) |
| Shaft seal faces |
Silicon carbide / silicon carbide |
| Seal and gasket rubber |
EPDM (HQQE) or FKM (HQQV) |
| Bearing |
Silicon carbide |
| ANSI flange and base plate |
Cast iron — does not contact the pumped liquid |
Applications
- Deionised and demineralised water, where iron pick-up from a cast iron head is unacceptable
- Water treatment, filtration and reverse osmosis feed
- Pressure boosting in commercial buildings and multi-unit residential
- Wash-down, food-adjacent and hygiene-sensitive process duty
- HVAC heating, chilled water and condenser water circulation
- Industrial process cooling and liquid transfer
What Is Supplied
Each part number is a complete pump: pump end, motor, coupling, coupling guard and shaft seal, factory assembled and tested.
Companion flanges are not included with ANSI flanged pumps and are ordered separately. The ANSI flanged version uses a cast iron flange and base plate; neither comes into contact with the pumped liquid, so the wetted path stays all stainless.
Motor starters, variable frequency drives, pressure sensors, base plates, foundation bolts and isolation valves are not included. These are fixed-speed pumps; for integrated variable-speed control see the CRIE range.
Ordering Information
Select the model, then the seal. Each combination is a distinct Grundfos part number, listed in the table above and shown in the SKU of the selected variant.
Not every combination exists — the picker shows only the combinations Grundfos publishes.
Before You OrderConfirm the duty point against the rated head table, and confirm horsepower, voltage and phase against your service. Single-phase and three-phase units are not interchangeable. Check that liquid temperature and system pressure sit inside the limits for the seal and connection selected.