Grundfos CRE 5 Variable-Speed Pump, 1 1/4 in ANSI, 4000 rpm

HP - Voltage: 3/4 HP - 200-240V 1Ph
Model: CRE 5-2
Sensor: With Sensor

Product variant with selected options does not exist!

Price
$3,290
SKU: 93285678
Weight : 72.9995 lb
Free Shipping $499 or more
Need it fast? Call for same-day shipping options: 281.664.8000
Description
GRUNDFOS · VARIABLE-SPEED VERTICAL MULTISTAGE PUMP
CRE 5 — 1 1/4 in ANSI, 4000 rpm
Vertical multistage pump with an integrated MLE variable-speed motor. 29.6 GPM rated flow at 3705-4000 rpm, 11 models from CRE 5-2 to CRE 5-20, 3/4 to 7-1/2 HP, HQQE cartridge seal, with or without a factory pressure sensor.
29.6 GPM Rated Flow
59-612 ft Rated Head
3/4 to 7-1/2 HP
Variable Speed
362 psi Max
Overview

CRE 5 is the CR platform with the drive built into the motor. The MLE motor carries its own frequency converter and a graphical control panel, so the pump varies its own speed to hold a setpoint instead of running flat out and throttling. There is no separate VFD to buy, mount, wire or commission.

Hydraulically it is a vertical multistage pump with suction and discharge on the same centreline, so it drops into a straight pipe run. Wetted parts are AISI 304 stainless with a cast iron pump head and base — the same material grade as CR.

This listing is the 4000 rpm, 1 1/4 in ANSI 250 lb flanged build. Grundfos publishes the 4000 rpm and 3600 rpm variants as separate part numbers with different duty points, so they are listed separately rather than mixed. At 3705-4000 rpm the CRE 5 frame is rated 29.6 GPM, and 11 stage counts cover 59 ft to 612 ft of rated head on 3/4 to 7-1/2 HP motors.

Speed is the whole point. The motor runs anywhere from 360 rpm up to its rated speed, so one pump covers a wide duty band and holds constant pressure as demand changes. That also means the published duty point below is the full-speed figure — at part load the pump sits lower on its curve and draws proportionally less power.

Genuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Performance — Will It Do What You Need?

A pump curve plots what the pump adds, not what comes out of the tap. The impeller does not know what pressure is on its inlet. Every figure below is pressure the pump adds to whatever already arrives — it is not a discharge pressure and it is not the controller setpoint.

Model HP Rated flow - GPM Rated head - ft Max head - ft Rated speed - rpm
CRE 5-2 1 29.6 59.48 83.01 3807
CRE 5-3 1-1/2 32.7 97.68 124.3 4000
CRE 5-4 2 31.8 114.9 165.7 3773
CRE 5-5 2 33.2 151.4 207 3878
CRE 5-6 2 33.2 175.4 248.4 3818
CRE 5-7 3 35.3 223.2 289.7 4000
CRE 5-9 3 33.4 258 372.1 3784
CRE 5-11 5 35.8 350.2 454.7 4000
CRE 5-13 5 35.6 409.8 537.1 3976
CRE 5-16 7-1/2 33.7 434.9 661.1 3705
CRE 5-20 7-1/2 35.7 611.7 826.2 3927

Grundfos published figures at the rated duty point, 60 Hz, at full speed. Rated head is the duty point at rated flow; max head is the shut-off ceiling at zero flow, not a working point. Rated speed is the published figure for each model and sits a little under the 4000 rpm nominal. Boost in psi equals head in feet multiplied by 0.433. For a duty between two models, or for flows away from 29.6 GPM, ask us to size it against the published curve.

Drawing from a tank, cistern or well. Nothing arrives with pressure, so what the pump adds is what you get. Read the table straight through: a CRE 5-7 gives you about 97 psi at 35.3 GPM.

Fed by a city main. The pump adds on top of what already arrives, and the controller holds the total. On a 40 psi main asking for 137 psi at the fixture, the pump only has to add 97 — and because it is variable speed it will do exactly that and no more. Incoming pressure buys you more flow, not more pressure.

With Sensor or Without — Which Do You Need?

With sensor. The pump ships with a factory pressure sensor and the wiring to it. Out of the box it holds a constant discharge pressure: set the pressure you want on the control panel and the pump varies its speed to maintain it. This is the version to order unless you already know otherwise.

Without sensor. The pump is the same machine with the same drive and panel, but no pressure sensor is supplied. It cannot hold constant pressure until a sensor is connected, or it is driven by an external signal or a building management system. Order this version only when the sensor already exists, is supplied by others, or the pump runs in constant-speed or externally-controlled mode.

The sensor range against each part number is the sensor’s measuring span — on this listing, 145 psi to 580 psi depending on model. That span is the ceiling on what the controller can be told to hold; it is not a claim about what the pump can produce. Read it together with the rated head table and the maximum operating pressure.

Models, Voltage & Sensor
Model HP Voltage & Phase Sensor Part No.
CRE 5-2 3/4 200-240V 1Ph With sensor, 0-145 psi 93285678
CRE 5-2 3/4 200-240V 1Ph Without sensor 93285575
CRE 5-2 1 200-240V 1Ph With sensor, 0-145 psi 93285679
CRE 5-2 1 200-240V 1Ph Without sensor 93285578
CRE 5-2 1 440-480V 3Ph With sensor, 0-145 psi 93286017
CRE 5-2 1 440-480V 3Ph Without sensor 93285925
CRE 5-3 1 440-480V 3Ph With sensor, 0-145 psi 93286018
CRE 5-3 1 440-480V 3Ph Without sensor 93285927
CRE 5-3 1-1/2 200-240V 1Ph With sensor, 0-145 psi 93285690
CRE 5-3 1-1/2 200-240V 1Ph Without sensor 93285579
CRE 5-3 1-1/2 440-480V 3Ph With sensor, 0-145 psi 93286019
CRE 5-3 1-1/2 200-240V 3Ph With sensor, 0-145 psi 93286330
CRE 5-3 1-1/2 440-480V 3Ph Without sensor 93285928
CRE 5-3 1-1/2 200-240V 3Ph Without sensor 93286251
CRE 5-4 1-1/2 200-240V 1Ph With sensor, 0-145 psi 93285691
CRE 5-4 1-1/2 200-240V 1Ph Without sensor 93285591
CRE 5-4 1-1/2 440-480V 3Ph With sensor, 0-145 psi 93286020
CRE 5-4 1-1/2 200-240V 3Ph With sensor, 0-145 psi 93287356
CRE 5-4 1-1/2 440-480V 3Ph Without sensor 93285929
CRE 5-4 1-1/2 200-240V 3Ph Without sensor 93286252
CRE 5-4 2 200-240V 1Ph With sensor, 0-145 psi 93285692
CRE 5-4 2 200-240V 1Ph Without sensor 93285592
CRE 5-4 2 440-480V 3Ph With sensor, 0-145 psi 93286021
CRE 5-4 2 200-240V 3Ph With sensor, 0-145 psi 93287358
CRE 5-4 2 440-480V 3Ph Without sensor 93285930
CRE 5-4 2 200-240V 3Ph Without sensor 93286253
CRE 5-5 2 200-240V 1Ph With sensor, 0-232 psi 93285693
CRE 5-5 2 200-240V 1Ph Without sensor 93285594
CRE 5-6 2 440-480V 3Ph With sensor, 0-232 psi 93286023
CRE 5-6 2 200-240V 3Ph With sensor, 0-232 psi 93287359
CRE 5-6 2 440-480V 3Ph Without sensor 93285931
CRE 5-6 2 200-240V 3Ph Without sensor 93286254
CRE 5-7 3 440-480V 3Ph With sensor, 0-232 psi 93286024
CRE 5-7 3 200-240V 3Ph With sensor, 0-232 psi 93287371
CRE 5-7 3 440-480V 3Ph Without sensor 93285932
CRE 5-7 3 200-240V 3Ph Without sensor 93286255
CRE 5-9 3 440-480V 3Ph With sensor, 0-232 psi 93286027
CRE 5-9 3 200-240V 3Ph With sensor, 0-232 psi 93287372
CRE 5-9 3 440-480V 3Ph Without sensor 93285933
CRE 5-9 3 200-240V 3Ph Without sensor 93286256
CRE 5-11 5 440-480V 3Ph With sensor, 0-362 psi 93286028
CRE 5-11 5 200-240V 3Ph With sensor, 0-362 psi 93287373
CRE 5-11 5 440-480V 3Ph Without sensor 93285935
CRE 5-11 5 200-240V 3Ph Without sensor 93286258
CRE 5-13 5 440-480V 3Ph With sensor, 0-362 psi 93286029
CRE 5-13 5 200-240V 3Ph With sensor, 0-362 psi 93287375
CRE 5-13 5 440-480V 3Ph Without sensor 93285936
CRE 5-13 5 200-240V 3Ph Without sensor 93286259
CRE 5-16 5 440-480V 3Ph With sensor, 0-362 psi 93286030
CRE 5-16 5 200-240V 3Ph With sensor, 0-362 psi 93287376
CRE 5-16 5 440-480V 3Ph Without sensor 93285937
CRE 5-16 5 200-240V 3Ph Without sensor 93286260
CRE 5-16 7-1/2 440-480V 3Ph With sensor, 0-362 psi 93286031
CRE 5-16 7-1/2 200-240V 3Ph With sensor, 0-362 psi 93287378
CRE 5-16 7-1/2 440-480V 3Ph Without sensor 93285939
CRE 5-16 7-1/2 200-240V 3Ph Without sensor 93286262
CRE 5-20 7-1/2 440-480V 3Ph With sensor, 0-580 psi 93286032
CRE 5-20 7-1/2 200-240V 3Ph With sensor, 0-580 psi 93287379
CRE 5-20 7-1/2 440-480V 3Ph Without sensor 93285941
CRE 5-20 7-1/2 200-240V 3Ph Without sensor 93286263

Voltage and phase are fixed per part number on an MLE motor — there is no terminal-board changeover as on a fixed-speed CR. Check the supply before ordering; single-phase and three-phase units are not interchangeable.

Key Features
  • Frequency converter built into the motor — no separate drive to buy, mount, wire or commission, and no drive panel to find space for.
  • 360-4000 rpm speed range — the pump throttles itself by slowing down rather than by closing a valve, which is where the energy saving comes from.
  • Graphical control panel with the FM300 - Advanced function module — setpoint, control mode and alarms are set on the pump itself.
  • IE5 motor efficiency class, enclosure IP55, with built-in electronic motor protection.
  • In-line ports — suction and discharge on the same level, so the pump installs in a straight run without an elbow or offset.
  • Cartridge shaft seal — HQQE, silicon-carbide faces, replaced as a complete unit without setting faces by hand.
  • NSF/ANSI 61 certified for drinking water contact.
  • 1 1/4 in ANSI 250 lb flanged connection — Grundfos type DIN / ANSI / JIS, rated PN 25.
Specifications
Specification Value
Rated flow at 60 Hz 29.6 GPM
Rated head range 59 to 612 ft
Maximum head at shut-off 826.2 ft on the tallest stack
Rated speed 3705-4000 rpm (4000 rpm nominal)
Speed range 360-4000 rpm
Motor power range 3/4 to 7-1/2 HP
Voltage and phase 200-240V 1Ph; 200-240V 3Ph; 440-480V 3Ph
Motor Grundfos MLE, integrated frequency converter, IE5, IP55
Control Graphical panel, FM300 - Advanced
Frequency 60 Hz
Suction and discharge port 1 1/4 in
Connection DIN / ANSI / JIS — 1 1/4 in ANSI 250 lb flanged, rated PN 25
Maximum operating pressure 362 psi
Maximum settable pressure Sensor span 145 psi to 580 psi depending on model — see the limits table, the pump rating is the other half of this
Liquid temperature range -4 .. 248 °F
Maximum ambient temperature 122 °F
Shaft seal HQQE — silicon-carbide faces, EPDM rubber
Pumped liquid Clean, thin, non-explosive liquids without solid particles or fibres
Pump orientation Vertical
Drinking water approval NSF/ANSI 61
Curve tolerance ISO9906:2012 3B
Materials
Component Material
Pump head and base Cast iron
Chambers and impellers Stainless steel, EN 1.4301 (AISI 304)
Shaft seal faces Silicon carbide / silicon carbide
Seal and gasket rubber EPDM
Bearing Silicon carbide (SiC)
Applications
  • Constant-pressure boosting in commercial buildings and multi-unit residential
  • Pressure boosting where demand swings through the day and a fixed-speed pump would cycle
  • Water treatment, filtration and reverse osmosis feed
  • HVAC heating, chilled water and condenser water circulation
  • Industrial process transfer where flow or pressure has to be held to a setpoint
  • Retrofits replacing a fixed-speed pump plus external VFD with one machine
Before You Buy — The Limits That Decide the Fit

The curve is one check of several, and rarely the one that fails.

Limit Why it decides the fit
Maximum settable pressure The sensor span is 145 psi to 580 psi depending on model, and that is the highest pressure the controller can be told to hold. The binding limit is whichever is lower — the sensor span, or what the pump can produce at your flow on top of your inlet pressure. A sensor rated above the pump’s body rating does not raise what the pump can deliver.
Maximum operating pressure 362 psi. This is inlet pressure plus what the pump adds. A strong city main can push a well-matched pump past its casing rating.
Suction lift A vertical multistage pump is not self-priming and will not pull a lift. It needs flooded suction or a positive inlet.
Power 200-240V 1Ph; 200-240V 3Ph; 440-480V 3Ph. Voltage and phase are fixed per part number on an MLE motor — this is the commonest cause of a redone quote.
Rated flow 29.6 GPM is the frame’s design point. Ask us for the curve before committing to a duty far from it.
Sensor A without-sensor unit cannot hold constant pressure until a sensor or an external signal is connected.
Liquid temperature -4 .. 248 °F, with a maximum ambient of 122 °F.
Pairing A single CRE runs on its own. Multi-pump staging is a Grundfos Hydro MPC or Hydro Multi-E system built around these pumps, specified as a set — ask us if that is what you need.
Sizing It So It Lasts

Best operating range. Grundfos does not publish an efficiency curve for this range in the product data, and a range cannot honestly be derived from a single published duty point, so we do not print one here. Send us the duty and we will read it off the curve for the exact model.

This is where the pump turns the most electricity into water pressure. Ask for more flow than it can deliver at your setting and it runs at full speed continuously, which is where motors and seals wear out. Sizing a booster to the building rather than to the headline numbers is what makes it last.

What Is Supplied

Each part number is a complete pump: pump end, MLE variable-speed motor with its built-in frequency converter and control panel, coupling, coupling guard and HQQE cartridge shaft seal, factory assembled and tested.

The pressure sensor is supplied only on the with-sensor part numbers. Check the Sensor column above against the part number you are ordering.

Companion flanges are not included with the ANSI flanged version and are ordered separately. Expansion tanks, isolation valves, external sensors, foundation bolts and building-management interfaces are not included.

Ordering Information

Select the HP and voltage, then the model, then whether you want the factory pressure sensor. Each combination is a distinct Grundfos part number, listed in the table above and shown in the SKU of the selected variant.

The picker shows only the combinations Grundfos publishes for the 1 1/4 in ANSI, 4000 rpm build.

Before You OrderConfirm the duty against the rated head table, remembering that those figures are what the pump adds at full speed. Check voltage and phase against your service — they are fixed per part number. Confirm the sensor range covers the pressure you intend to hold, and that inlet pressure plus added pressure stays inside the body rating. This pump needs flooded suction.
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.
© Watermain Supply — A division of E4 Industrial LLC
Data Sheet

The full CRE 60 Hz data booklet, dimensional drawings and a factory submittal are available on request — email sales@watermainsupply.com with the part number.