Grundfos CR 95 Vertical Multistage Pump End, Motor Not Included

HP - NEMA Frame: 15 HP - 254TCZ
Shaft Seal: HQQE - EPDM
Connection - Model - Max: ANSI - CR 95-1-1 - 51 PSI Max, 655 GPM Max

Product variant with selected options does not exist!

Price
$5,863.86
SKU: 99400147
Weight : 505.0 lb
Loading locations...
Free Shipping $499 or more
Skip the chatbot. Talk to an expert.
1-888.510.4036 · Same-day shipping available
Description
GRUNDFOS · VERTICAL MULTISTAGE PUMP END
CR 95 Pump End
Vertical multistage pump end in cast iron and 304 stainless steel, motor not included. 13 models from CR 95-1-1 to CR 95-5-1 for 15 to 75 HP NEMA motors (254TCZ to 365TSCZ frames), 4 in ANSI flanged ports, HQQE or HQQV cartridge shaft seal.
119-699 ft (51-302 PSI) Max Head · 655 GPM Max
Fits 15-75 HP NEMA Motors, Frame 254TCZ to 365TSCZ
4 in ANSI Ports
In-Line Suction and Discharge
232-363 PSI Max Operating Pressure
229-300 lb Weight
Overview

The CR 95 pump end is the hydraulic part of a Grundfos CR 95 vertical multistage pump, supplied without a motor: order it to rebuild an existing CR 95, to change the number of stages for a new duty, or to build a pump on a motor you already have. The pump head and base are cast iron; the impellers, chambers, shaft and other wetted parts are stainless steel (EN 1.4301, AISI 304). Suction and discharge sit on the same level, so it drops into a straight pipe run. The CR 95 is rated at 500 GPM (Grundfos rated flow); size it from the performance table below rather than from the model number.

  • 13 models, CR 95-1-1 to CR 95-5-1, each built for a NEMA C-face motor of 15 to 75 HP (motor table below)
  • 4 in ANSI flanges, 150 lb (CR 95-1-1 to CR 95-4-1) or 300 lb (CR 95-4 to CR 95-5-1)
  • Drop-in versions (CR 95-1-1 to CR 95-5-1, ANSI flanged) are the CR 95 built to replace an existing Grundfos CR 90 in the same space; Grundfos says to order them only for that (price list)
  • HQQE (EPDM) or HQQV (FKM) cartridge shaft seal with silicon-carbide faces
  • Maximum operating pressure: 232-363 PSI by model
What Ships and What It Needs to Run

Included: the CR 95 pump end and the motor coupling (Grundfos price list).

Motor required, ordered separately. A NEMA C-face motor at the horsepower and frame shown for your model in the motor table under Models & Performance (15 to 75 HP), with the starter or drive that motor needs. Grundfos specifies a smooth-shaft motor, or a keyed shaft with a half key, for balanced running (price list).

ANSI companion flanges required, ordered separately. Grundfos supplies the companion connections as a separate 4 in set (Grundfos price list).

Suction and discharge piping, valves and controls: sized to your system and ordered separately.

Genuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.
Warranty: 24 months from date of installation, but not more than 30 months from date of manufacture (Grundfos limited warranty). Grundfos repairs or replaces its own product; costs of removal, installation and transportation are not covered, and products sold but not manufactured by Grundfos carry their own manufacturer’s warranty.
Specifications
Specification Value
Product Pump end only: hydraulic assembly and motor coupling, motor not included
Rated flow at 60 Hz 500 GPM (Grundfos rated flow)
Motor required NEMA C-face, 15 to 75 HP; frames 254TCZ, 284TSCZ, 324TSCZ, 364TSCZ, 365TSCZ (by model, see motor table)
Suction and discharge ports In-line; 4 in
Connections 4 in ANSI flanges, 150 lb (CR 95-1-1 to CR 95-4-1) or 300 lb (CR 95-4 to CR 95-5-1); Drop-in versions (replace an existing CR 90) on ANSI flanges
Maximum operating pressure 232-363 PSI by model
Liquid temperature Up to 248 °F with HQQE; up to 194 °F with HQQV
Shaft seal HQQE (EPDM) or HQQV (FKM) cartridge seal, SiC/SiC faces
Pump orientation Vertical
Frequency 60 Hz
App None: a mechanical pump end with no electronics
Models & Performance — Will It Do What You Need?

Find the pressure you need at your flow and pick the first model that reaches it. Pressure at flow in PSI, one row per model.

CR 95-1-1 to CR 95-4 · 11 models
Model 0 GPM (Shut-off) 131 GPM 328 GPM 491 GPM 655 GPM
CR 95-1-1 51 50 44 34 16
CR 95-1 64 62 55 46 29
CR 95-2-2 100 100 90 68 30
CR 95-2-1 113 111 101 80 43
CR 95-2 126 123 112 93 57
CR 95-3-2 162 161 147 115 59
CR 95-3-1 176 174 160 129 74
CR 95-3 190 186 171 143 89
CR 95-4-2 226 224 207 165 91
CR 95-4-1 240 236 218 178 105
CR 95-4 254 249 231 193 121
CR 95-5-2 to CR 95-5-1 · 2 models
Model 0 GPM (Shut-off) 131 GPM 328 GPM 491 GPM 655 GPM
CR 95-5-2 289 286 265 214 121
CR 95-5-1 302 298 277 227 135

Pressure the pump end develops at each flow, in PSI, rounded down (feet = PSI × 2.31), with the motor shown in the motor table. Shut-off is Grundfos’s published maximum head for each model (CR 95-4 is not in the Grundfos US catalog: shut-off read from the curve at zero flow). Flow columns are digitized from the published 60 Hz curve in the CR, CRN 95-255 Data Booklet (60 Hz, 2026), p. 24 (water at 68 °F), and rounded down, at about 20%, 50% and 75% of 655 GPM, the last regular flow every curve in this listing reaches; the curves end at 655.8 GPM. Full curves are in the product images.

Motor each model needs (Grundfos price list and catalog; the motor is ordered separately):

CR 95-1-1 to CR 95-5-1 · 13 models · 15 to 75 HP
Model Motor HP NEMA frame
CR 95-1-1 15 254TCZ
CR 95-1 20 254TCZ
CR 95-2-2 25 284TSCZ
CR 95-2-1 30 284TSCZ
CR 95-2 30 284TSCZ
CR 95-3-2 40 324TSCZ
CR 95-3-1 50 324TSCZ
CR 95-3 50 324TSCZ
CR 95-4-2 60 364TSCZ
CR 95-4-1 60 364TSCZ
CR 95-4 75 365TSCZ
CR 95-5-2 75 365TSCZ
CR 95-5-1 75 365TSCZ
Before You Buy — The Limits That Decide the Fit
Check What decides the fit
Motor Order a NEMA C-face motor at the HP and frame Grundfos lists for your model in the motor table under Models & Performance. Use a smooth-shaft motor or a keyed shaft with a half key (Grundfos price list).
Duty point The model’s pressure at your flow must cover the system’s total head; the shut-off column is Grundfos’s published maximum head, the most the model can make.
Working pressure Inlet pressure plus the pressure the pump adds must stay within the maximum operating pressure: 232-363 PSI by model.
Liquid temperature Up to 248 °F with HQQE; up to 194 °F with HQQV.
Connections ANSI companion flanges (4 in) ordered separately. Match the connection to the existing pipework. Choose a Drop-in version only to replace an existing CR 90.
Shaft seal HQQE has EPDM rubber parts and HQQV has FKM; choose the rubber that suits the pumped liquid.
Applications

HVAC heating and air conditioning, district heating and cooling, plumbing pressure boosting, industrial water supply and transfer, process liquids, wash and clean, water treatment, irrigation and ground water transfer (Grundfos CR range applications).

Materials of Construction
Component Material
Pump head and base Cast iron
Impellers, chambers, shaft Stainless steel EN 1.4301 (AISI 304)
Shaft seal faces Silicon carbide / silicon carbide (HQQ cartridge seal)
Seal and gasket rubber EPDM (HQQE) or FKM (HQQV)
For engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036.