SQ is a 3-inch diameter deep well submersible pump designed for pumping raw water in domestic water supply, and is suitable for both continuous and intermittent operation. Typical applications are domestic water supply, light commercial service, irrigation and tank applications. The pump fits 3 in and larger boreholes. SQ pumps feature a permanent-magnet motor combined with a Grundfos micro-frequency converter, giving soft start and integrated dry-run protection. SQ models operate at a constant speed much like conventional pumps; the difference is that SQ delivers the benefits of an electronically controlled permanent-magnet motor that cannot be achieved with a conventional induction motor. A simple 2-wire single-phase design means only an on/off switch is needed โ no control box, starter box or capacitor.
The pumps are protected against dry running. A value of Pcut-out ensures cut-out of the pump in case of lack of water in the borehole, thus preventing a burnout of the motor. Pcut-out is factory-set. The integrated protection of all motors prevents damage in case the voltage moves outside the permissible range: the pump will cut out if the voltage falls below 150 V or rises above 315 V, and the motor is automatically cut in again when the voltage returns within range. Therefore no extra protection relay is needed. Exposure of the pump to heavy load causes the current consumption to rise; the motor automatically compensates by reducing the speed to 3000 rpm, and further overload will lead to stop. If the rotor is prevented from rotating, this is automatically detected and the power supply is cut out. Consequently, no extra motor protection is needed.
The pump design features floating impellers that are not fastened to the shaft. Each impeller has its own tungsten carbide / ceramic bearing, and the construction and materials ensure high wear resistance to sand for long product life. The hydraulic pump components are polyamide reinforced with 30 % glass fiber; the hydraulic design provides for high pump efficiency resulting in low energy consumption. Starting up a pump with very low counter pressure involves the risk of the entire impeller stack being lifted, also called upthrust, which may cause breakdown of both pump and motor. A top bearing protects both pump and motor against upthrust, thus preventing breakdown during the critical start-up phase.
A built-in check valve with spring and low weight mean the pump may be installed vertically, horizontally or in any position in between, but it must not fall below the horizontal level in relation to the motor. For horizontal installation a flow sleeve is recommended, to ensure sufficient flow velocity past the motor for cooling and to prevent the motor and electronic unit from being buried in sand or mud.
Find your model down the left, then the pressure you want in the PSI column and the depth to pumping water level across the top. The figure is gallons per minute at that duty point. Rows cover 30 to 60 PSI; the full 0 to 60 PSI set for every model is in the sizing guide on the Data Sheet tab.
| Model | HP | PSI | 20 | 40 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 | 220 | 240 | 260 | 280 | 300 | 340 | 400 | 460 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 15 SQ05-70 | 1/2 | 30 | - | 7.1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 40 | 5.9 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| Shut-off PSI | 42 | 33 | 25 | 16 | 7 | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 15 SQ05-110 | 1/2 | 30 | - | - | - | - | 8.3 | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 40 | - | - | - | 7.0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 50 | - | - | 6.2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 60 | - | 5.0 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| Shut-off PSI | 71 | 62 | 53 | 45 | 36 | 27 | 19 | 10 | - | - | - | - | - | - | - | - | - | - | ||
| 15 SQ07-150 | 3/4 | 30 | - | - | - | - | - | - | - | 6.6 | - | - | - | - | - | - | - | - | - | - |
| 40 | - | - | - | - | - | - | 5.9 | - | - | - | - | - | - | - | - | - | - | - | ||
| 50 | - | - | - | - | 9.9 | 4.8 | - | - | - | - | - | - | - | - | - | - | - | - | ||
| 60 | - | - | - | 9.0 | 3.9 | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
| Shut-off PSI | 97 | 88 | 79 | 71 | 62 | 53 | 45 | 36 | 27 | 19 | 10 | - | - | - | - | - | - | - | ||
| 15 SQ07-180 | 3/4 | 30 | - | - | - | - | - | - | - | - | - | 9.5 | 6.5 | - | - | - | - | - | - | - |
| 40 | - | - | - | - | - | - | - | - | 9.5 | 5.6 | - | - | - | - | - | - | - | - | ||
| 50 | - | - | - | - | - | - | - | 9.0 | 4.8 | - | - | - | - | - | - | - | - | - | ||
| 60 | - | - | - | - | - | - | 8.2 | - | - | - | - | - | - | - | - | - | - | - | ||
| Shut-off PSI | 122 | 113 | 105 | 96 | 87 | 79 | 70 | 61 | 53 | 44 | 35 | 27 | 18 | 10 | - | - | - | - | ||
| 15 SQ10-220 | 1 | 30 | - | - | - | - | - | - | - | - | - | - | - | - | 9.3 | 6.0 | - | - | - | - |
| 40 | - | - | - | - | - | - | - | - | - | - | - | 8.8 | 5.0 | - | - | - | - | - | ||
| 50 | - | - | - | - | - | - | - | - | - | - | 8.3 | 4.3 | - | - | - | - | - | - | ||
| 60 | - | - | - | - | - | - | - | - | - | 7.7 | - | - | - | - | - | - | - | - | ||
| Shut-off PSI | 149 | 140 | 132 | 123 | 114 | 106 | 97 | 88 | 80 | 71 | 62 | 54 | 45 | 36 | 28 | 10 | - | - | ||
| 15 SQ10-250 | 1 | 30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 6.1 | 5.4 | - | - |
| 40 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 8.1 | - | - | - | ||
| 50 | - | - | - | - | - | - | - | - | - | - | - | - | 9.7 | 7.8 | 4.5 | - | - | - | ||
| 60 | - | - | - | - | - | - | - | - | - | - | - | 9.7 | 7.4 | 3.5 | - | - | - | - | ||
| Shut-off PSI | - | 166 | 157 | 148 | 140 | 131 | 123 | 114 | 105 | 97 | 88 | 79 | 71 | 62 | 53 | 36 | 10 | - | ||
| 15 SQ15-290 | 1-1/2 | 30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 5.1 | - |
| 40 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 9.7 | - | - | ||
| 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 7.4 | - | - | ||
| 60 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 9.1 | - | - | - | ||
| Shut-off PSI | - | - | 184 | 175 | 166 | 158 | 149 | 140 | 132 | 123 | 114 | 106 | 97 | 88 | 80 | 62 | 36 | 10 |
Depth figures are feet to pumping water level, not total well depth. Values do not account for friction loss in the drop pipe or the discharge line โ add that to your pressure requirement before selecting. A hyphen to the left of a modelโs published range means the duty point sits above the charted flow limit for that pump; a hyphen to the right means the pump will not deliver at that combination. Shut-off PSI is the pressure at zero flow at that depth โ a ceiling, not a working point. Data from the Grundfos 3 in SQ Sizing Guide. Grundfos publishes no sizing chart for 15 SQ15-330; size that model from the published pump curve or email us.
| Model | HP | Voltage & Phase | Discharge | Part No. |
|---|---|---|---|---|
| 15 SQ05-70 | 1/2 | 115V 1Ph | 1-1/4 in NPT | 96160168 |
| 15 SQ05-110 | 1/2 | 115V 1Ph | 1-1/4 in NPT | 96160169 |
| 15 SQ05-70 | 1/2 | 230V 1Ph | 1-1/4 in NPT | 96160146 |
| 15 SQ05-110 | 1/2 | 230V 1Ph | 1-1/4 in NPT | 96160147 |
| 15 SQ07-150 | 3/4 | 230V 1Ph | 1-1/4 in NPT | 96160148 |
| 15 SQ07-180 | 3/4 | 230V 1Ph | 1-1/4 in NPT | 96160149 |
| 15 SQ10-220 | 1 | 230V 1Ph | 1-1/4 in NPT | 96160150 |
| 15 SQ10-250 | 1 | 230V 1Ph | 1-1/4 in NPT | 96160151 |
| 15 SQ15-290 | 1-1/2 | 230V 1Ph | 1-1/4 in NPT | 96160152 |
| 15 SQ15-330 | 1-1/2 | 230V 1Ph | 1-1/4 in NPT | 93001423 |
All 15 SQ models are single phase. The 1/2 HP models are built in two separate motor versions, 1 x 100-115 V and 1 x 200-240 V, ordered as different part numbers โ they are not field-convertible and there is no terminal board to change. The 3/4, 1 and 1-1/2 HP models are 200-240 V only.
| Specification | Value |
|---|---|
| Mains supply to pump | 1 x 200-240 V -10 % / +6 %, 50/60 Hz, PE or 1 x 100-115 V -10 % / +6 %, 50/60 Hz, PE |
| Phase | Single phase, 2-wire |
| Power factor | PF = 1 |
| Starting | Soft starting |
| Run-up time | Maximum 3 seconds. No limitation to the number of starts/stops per hour |
| Starting current | Equal to the highest value stated on the motor nameplate |
| Motor protection | Built-in: dry running, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, overtemperature |
| Motor | MS 3 permanent-magnet submersible motor, water-lubricated slide bearings, factory-filled with SML-3 motor liquid |
| Motor cable | 3 wire, 14 AWG XLPE, 5 ft |
| Pipe connection | 1-1/4 in NPT (male thread must be NPT type) |
| Borehole diameter | Minimum 3 in |
| Installation depth | Maximum 500 ft below the static water table. Minimum 1.65 ft below dynamic water level |
| NPSH | Minimum 27 ft |
| Strainer | Holes in the suction strainer 0.075 in diameter |
| Pumped liquids | SQ (AISI 304): pH 5 to 9. Clear, cold water free of air or gases |
| Liquid temperature | Minimum 34 ยฐF, maximum 86 ยฐF |
| Storage temperature | -4 ยฐF to +140 ยฐF, frost-free or with frost-proof motor liquid |
| Pump diameter | 2.68 in; 2.91 in including cable guard |
| Operation via generator | Generator output equal to motor input power P1 plus 50 %, and at least P1 plus 10 % |
| Earth leakage circuit breaker | Where an ELCB is used as additional protection it must trip when earth fault currents with pulsating DC content occur |
| Radio noise | Complies with EMC Directive 2014/30/EU |
| Model | HP | Full load A, 230V | Full load A, 115V | Overload A, 230V | Overload A, 115V | A โ overall in | B โ motor in | C โ pump end in | Ship wt lb |
|---|---|---|---|---|---|---|---|---|---|
| 15 SQ05-70 | 1/2 | 2.9 | 6.0 | 5 | 11 | 29.1 | 19.0 | 10.1 | 11 |
| 15 SQ05-110 | 1/2 | 4.0 | 8.3 | 5 | 11 | 29.1 | 19.0 | 10.1 | 11 |
| 15 SQ07-150 | 3/4 | 5.1 | โ | 8 | โ | 30.2 | 19.0 | 11.2 | 13 |
| 15 SQ07-180 | 3/4 | 6.2 | โ | 8 | โ | 32.4 | 19.0 | 13.3 | 13 |
| 15 SQ10-220 | 1 | 7.4 | โ | 11 | โ | 33.8 | 20.4 | 13.3 | 14 |
| 15 SQ10-250 | 1 | 8.4 | โ | 11 | โ | 34.8 | 20.4 | 14.4 | 15 |
| 15 SQ15-290 | 1-1/2 | 9.7 | โ | 12 | โ | 37.0 | 20.4 | 16.5 | 16 |
| 15 SQ15-330 | 1-1/2 | 10.5 | โ | 12 | โ | 37.0 | 20.4 | 16.5 | 16 |
Grundfos publishes one motor-data table for the SQ/SQE range in the current data booklet and prints it under the SQE type designations; the figures above are those values. Confirm against the motor nameplate before sizing conductors or overcurrent protection, and select drop cable from the cable-sizing table under Ordering Information. Dimensions D and E โ pump diameter and diameter including cable guard โ are 2.6 in and 2.9 in on every model.
| Component | Material | EN | AISI |
|---|---|---|---|
| Outlet chamber | Stainless steel | 1.4301 | 304 |
| Pump sleeve | Stainless steel | 1.4301 | 304 |
| Shaft with coupling | Stainless steel / sintered steel | 1.4301 | 304 |
| Cable guard | Stainless steel | 1.4301 | 304 |
| Screws for cable guard | Stainless steel | 1.4401 | 316 |
| Impeller with tungsten carbide bearing | Polyamide | โ | โ |
| Guide vanes, chambers, valve casing | Polyamide | โ | โ |
| Valve seat, top bearing, O-ring, lip seal ring | NBR rubber | โ | โ |
| Neck ring | TPU / PBT | โ | โ |
| Lock ring | Stainless spring steel | 1.4310 | 310 |
| Spring | Stainless spring steel | 1.4406 | 316LN |
| Motor stator, rotor, top cover | Stainless steel | 1.4301 | 304 |
| Motor thrust bearing | Carbon | โ | โ |
| Motor radial bearings, upper and lower | Silicon carbide / tungsten carbide coating | โ | โ |
| Motor liquid | SML-3 | โ | โ |
SQ is normally installed with a pressure switch and a pressure tank. Where constant pressure is wanted, the SQE version of the same hydraulics adds a variable-speed Smart Motor that works with the CU 302 control unit.
Type key. In 15 SQ05-70: 15 is rated gallons per minute, SQ is the type range (basic version, without communication), 05 is horsepower and -70 is total dynamic head in feet at rated flow.
Order by part number. 15 SQ05-70 โ 96160146; 15 SQ05-110 โ 96160147; 15 SQ07-150 โ 96160148; 15 SQ07-180 โ 96160149; 15 SQ10-220 โ 96160150; 15 SQ10-250 โ 96160151; 15 SQ15-290 โ 96160152; 15 SQ15-330 โ 93001423. The 1/2 HP models carry a second part number for the 100-115 V version: 15 SQ05-70 โ 96160168; 15 SQ05-110 โ 96160169.
Cable sizing. Maximum drop cable length in feet by copper wire size:
| Volts | HP | Amps | 14 AWG | 12 AWG | 10 AWG | 8 AWG | 6 AWG | 4 AWG | 2 AWG |
|---|---|---|---|---|---|---|---|---|---|
| 115 | 1/2 | 12 | 140 | 220 | 360 | 550 | 880 | 1390 | 2260 |
| 230 | 1/2 | 5.2 | 640 | 1000 | 1660 | 2250 | 4060 | โ | โ |
| 230 | 3/4 | 8.4 | 400 | 620 | 1030 | 1580 | 2510 | 3970 | โ |
| 230 | 1 | 11.2 | 300 | 460 | 770 | 1190 | 1890 | 2980 | 4850 |
| 230 | 1-1/2 | 12 | 280 | 430 | 720 | 1110 | 1760 | 2780 | 4530 |
Accessories. SQ, SQE flow sleeve, complete โ product number 98148594. SP, SQ, SQE wrench โ 99588350. Cable kit, SQ SQE 14 AWG 5 ft NSF, motor model C โ 97778332. The flow sleeve is recommended for horizontal installation and wherever the motor may be covered by sediment or sits below the well screen.
Grundfos 3 in SQ vs. a Conventional 4 in Submersible (5:49)
SQ and SQE: Constant Pressure Pump Overview (4:02)
How the 3 in Grundfos SQ Saved an Old Water Well (3:09)
Grundfos SQ in the Field with R&D Water Wells, Dayton, Texas (2:12)
Field Review: Grundfos 3 in SQ Submersible (1:25)