DAB · Self-Priming Jet Pump
JET 150-PS / 200-PS
Cast iron self-priming jet pumps with a fitted pressure switch, 1.5 and 2 HP, lifting water from as deep as 29 ft.
215-218 ft (93-94 PSI) Max Head · 23-34 GPM Max
1.5-2 HP
230V 1Ph
Self-Priming to 29 ft
Pressure Switch Fitted
1-1/4 in Suction, 1 in Discharge NPT
Cast Iron Body
115 PSI Max Working Pressure
CSA C22.2, UL 778
22.0-24.9 x 9.8 x 10.0 in
69.5-77.1 lb Weight
Indoor or Weather-Protected Install
Overview
The DAB JET is a self-priming centrifugal jet pump that lifts water from as deep as 29 ft, even with air bubbles in the suction line, for home water supply, gardens, small farms and light industrial service. A cast iron body and motor frame carry twin technopolymer impellers, a venturi and a sand filter; the closed, fan-cooled motor has built-in thermal and current protection. The pressure switch comes fitted, so the pump starts and stops on its own.
-
Self-priming to 29 ft, handling air in the suction line.
-
Pressure switch fitted at DAB’s factory setting, adjustable.
-
Cast iron pump body and motor frame; technopolymer impellers, venturi and nozzle group.
-
Carbon/ceramic mechanical seal; greased-for-life oversized ball bearings.
-
Motor protection built in: thermal and current overload with automatic reset, permanent capacitor.
What Ships and What It Needs to Run
Included: the JET pump with its built-in venturi and nozzle group, the single-phase motor with built-in overload protection, and a pressure switch fitted at DAB’s factory setting.
Pressure tank, foot valve and suction pipe: sized to your installation and ordered separately. DAB advises a foot valve on the suction line and a suction pipe no smaller than the pump inlet.
Genuine DAB equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking DAB Distributor.
24-Month DAB Warranty
Covered for 24 months from the date of purchase under DAB’s published warranty terms, evidenced by the invoice or delivery document.
Specifications
| Power supply |
1 x 230 V, 60 Hz |
| Connections |
1-1/4 in NPT suction, 1 in NPT discharge |
| Maximum suction depth |
29 ft |
| Maximum operating pressure |
115 psi |
| Liquid temperature |
32 F to 95 F for domestic use; 32 F to 104 F otherwise |
| Maximum ambient temperature |
104 F |
| Motor |
Asynchronous, closed, external fan cooling; insulation class F |
| Installation |
Fixed, horizontal; indoors or protected from the weather |
| Approvals |
CSA C22.2 No. 108-14; UL 778 |
Models & Performance — Will It Do What You Need?
Find your model, then read across. Subtract your suction lift (1 PSI for every 2.31 ft) and pipe friction from the figure to get the pressure at the tank.
Models
| Model |
HP |
kW |
Amps |
Service factor |
| JET 150-PS |
1.5 |
1.1 |
7.7 |
1.3 |
| JET 200-PS |
2 |
1.85 |
10.5 |
1.2 |
JET 150-PS — PSI at flow
| Model |
0 GPM (Shut-off) |
5 GPM |
12 GPM |
18 GPM |
23.8 GPM (Max) |
| JET 150-PS |
93 |
73 |
76 |
67 |
9 |
JET 200-PS — PSI at flow
| Model |
0 GPM (Shut-off) |
7 GPM |
17 GPM |
26 GPM |
34.3 GPM (Max) |
| JET 200-PS |
94 |
81 |
76 |
65 |
31 |
Digitized from the curves DAB plots on the JET 150-PS / 200-PS data sheet (DAB tabulates no figures), at the flows nearest 20%, 50% and 75% of each curve’s end, rounded down to whole PSI; feet = PSI × 2.31 (shut-off 215 ft and 218 ft). The JET 150 curve dips to about 168 ft near 6 GPM and recovers to 178 ft near 13 GPM, as DAB draws it; on the JET 200, DAB plots three points and the values between are its smoothing. Suction lift is not deducted. Curve tolerance to ISO 9906.
Before You Buy — The Limits That Decide the Fit
| Pressure switch |
Fitted at DAB’s factory setting and adjustable; keep the cut-out below the pump’s shut-off (93 PSI on the 150, 94 PSI on the 200) minus your suction lift |
| Suction lift |
29 ft maximum |
| Priming |
Fill the pump completely with water before the first start; after that it primes itself, even with air in the line |
| Power |
230 V single phase only |
| Pressure tank |
Set the precharge about 3 psi (0.2 bar) below the pump’s cut-in pressure |
| Drinking water |
DAB’s published approvals are CSA and UL; ask us for drinking-water documentation before a potable install |
Installation Notes
- Install horizontally, in a ventilated place protected from the weather, with the ambient at 104 F or less.
- Anchor the pump firmly and keep pipe weight off its connections.
- Fit a foot valve on the suction; keep the suction pipe at least the size of the pump inlet.
- For lifts over 13 ft or long horizontal runs, use a larger suction pipe sloping slightly up toward the pump.
- Allow no more than 20 starts per hour.
- In freezing weather, drain the pump body through the drain cap if it will stand idle.
From the DAB JET instruction manual (60119973) and pressure switch instructions.
Applications
Domestic water supply from shallow wells, tanks and cisterns, small farms, gardening, small-scale industrial service, and water with low levels of sandy impurities.
Materials of Construction
| Pump body |
Cast iron GJL 200 |
| Frame |
Cast iron GJL 200 |
| Impeller |
PPO-GF 20 (Noryl) |
| Venturi diffuser and nozzle group |
PPO-GF 20 (Noryl) |
| Shaft with rotor |
Stainless steel AISI 303 |
| Mechanical seal |
Carbon / ceramic |
| O-ring |
NBR rubber |
Parts in contact with the water, from the DAB JET 150-200-300 data sheet.