Find your horsepower in the row, then read across. Total head is the lift from the pumping water level to the discharge, plus the pressure you want at the tank (2.31 ft for every PSI), plus friction in the drop pipe.
Total head in feet · curves end at 27.5–30 GPM
| HP |
0 GPM (Shut-off) |
5 GPM |
15 GPM |
22.5 GPM |
25 GPM |
| 1/2 HP |
173 ft |
166 ft |
121 ft |
78 ft |
52 ft |
| 3/4 HP |
233 ft |
220 ft |
168 ft |
102 ft |
69 ft |
| 1 HP |
291 ft |
280 ft |
207 ft |
128 ft |
89 ft |
| 1 1/2 HP |
383 ft |
362 ft |
277 ft |
167 ft |
120 ft |
| 2 HP |
505 ft |
475 ft |
363 ft |
212 ft |
148 ft |
| 3 HP |
660 ft |
620 ft |
484 ft |
296 ft |
223 ft |
| 5 HP |
1051 ft |
984 ft |
771 ft |
452 ft |
329 ft |
Read from the published curve in the Pumps by Baker catalog (Sept 2025, rev 3/26), p. 60, digitized and rounded down, at the flows nearest 20%, 50% and 75% of the curve’s 30 GPM end. 0 GPM is the printed shut-off. For the 1/2 HP (the curve reads 184 ft at zero flow against the printed 173 ft), the printed shut-off is shown. The last column is the last flow every curve reaches; the curve ends are named in the table title.
Output in GPM at 30 PSI (switch cut-in), by depth to water
| HP |
25 ft |
50 ft |
100 ft |
150 ft |
200 ft |
250 ft |
300 ft |
| 1/2 HP |
20.00 |
16.14 |
2.99 |
— |
— |
— |
— |
| 3/4 HP |
22.98 |
20.62 |
14.94 |
5.91 |
— |
— |
— |
| 1 HP |
24.55 |
22.79 |
18.83 |
13.92 |
6.60 |
— |
— |
| 1 1/2 HP |
— |
24.78 |
22.16 |
19.20 |
15.74 |
11.35 |
4.06 |
| 2 HP |
— |
26.10 |
24.18 |
22.11 |
19.84 |
17.33 |
14.44 |
| 3 HP |
— |
27.72 |
26.34 |
24.87 |
23.33 |
21.67 |
19.90 |
| 5 HP |
— |
28.60 |
27.79 |
26.95 |
26.08 |
25.19 |
24.26 |
Output in GPM at 50 PSI (switch cut-out), by depth to water
| HP |
25 ft |
50 ft |
100 ft |
150 ft |
200 ft |
250 ft |
300 ft |
| 1/2 HP |
12.08 |
4.85 |
— |
— |
— |
— |
— |
| 3/4 HP |
18.40 |
15.44 |
6.92 |
— |
— |
— |
— |
| 1 HP |
21.19 |
19.15 |
14.34 |
7.36 |
— |
— |
— |
| 1 1/2 HP |
— |
22.37 |
19.44 |
16.03 |
11.73 |
4.93 |
— |
| 2 HP |
— |
24.33 |
22.27 |
20.02 |
17.53 |
14.68 |
11.25 |
| 3 HP |
— |
26.44 |
24.99 |
23.45 |
21.80 |
20.04 |
18.11 |
| 5 HP |
— |
27.85 |
27.01 |
26.15 |
25.26 |
24.33 |
23.38 |
Output tables as printed in the Pumps by Baker catalog (Sept 2025, rev 3/26), pp. 59-60, at the 30 and 50 PSI rows. Riser-pipe friction is not included (manufacturer note): add it for long or small drop pipe. — marks a point A.Y. McDonald does not print for that horsepower.
Best operating range: the published curve shades the most efficient operating range for each model; the catalog prints no figures for it. The curve is in the image gallery.