Grundfos GNTA tanks are ASME diaphragm expansion tanks for closed hydronic heating and chilled water systems. As the system heats up, the water expands into the tank against an air cushion held behind a heavy-duty butyl diaphragm, keeping system pressure steady and below the relief valve setting. The diaphragm is fixed (not replaceable) and the tank is partial acceptance: the acceptance volume in the table is the most system water the tank can take.
The tank is factory pre-charged and field adjustable; set the pre-charge to the system fill pressure at the tank before filling.
Included: the GNTA tank with factory-installed diaphragm and charging valve.
Ships: about 42-591 lb by model, by LTL freight to a commercial dock; liftgate or residential delivery is a paid checkout option. Larger tanks ship on their own skid or base ring.
Needed to install: isolation valve and drain at the system connection, a pressure gauge or tire gauge to set the pre-charge, and a level floor or pad rated for the full-of-water weight.
| Tank type | Fixed diaphragm, partial acceptance |
| Code | ASME Section VIII Division 1 |
| Max working pressure | 150 PSI (GNTA-15 to GNTA-60), 125 PSI (all larger) |
| Max temperature | 240°F |
| Pre-charge | Factory set, field adjustable |
| Model | Part no. | Gallons | Acceptance (gal) | Dia. x height (in) | System conn. | Max pressure | Weight (lb) |
|---|---|---|---|---|---|---|---|
| GNTA-15 | 99426692 | 7.8 | 6.3 | 12 x 19 | 3/4 in | 150 PSI | 42 |
| GNTA-20 | 99426697 | 11 | 8.8 | 12 x 25 | 3/4 in | 150 PSI | 52 |
| GNTA-40 | 99426701 | 25 | 20 | 16 x 33 | 1 in | 150 PSI | 84 |
| GNTA-60 | 99426709 | 35 | 28 | 16 x 44 | 1 in | 150 PSI | 97 |
| GNTA-80 | 99426725 | 45 | 36 | 20 x 38 | 1 in | 125 PSI | 148 |
| GNTA-100 | 99426727 | 60 | 48 | 20 x 49 | 1 in | 125 PSI | 175 |
| GNTA-120 | 99426704 | 70 | 56 | 24 x 46 | 1-1/2 in | 125 PSI | 259 |
| GNTA-144 | 99426707 | 80 | 65 | 24 x 49 | 1-1/2 in | 125 PSI | 268 |
| GNTA-180 | 99426772 | 90 | 73 | 24 x 52 | 1-1/2 in | 125 PSI | 283 |
| GNTA-200 | 99426784 | 115 | 93 | 24 x 66 | 1-1/2 in | 125 PSI | 325 |
| GNTA-240 | 99426788 | 140 | 114 | 24 x 78 | 1-1/2 in | 125 PSI | 362 |
| GNTA-260 | 99426790 | 158 | 128 | 30 x 63 | 1-1/2 in | 125 PSI | 591 |
Weights are Grundfos’s published figures (approximate shipping weight). Dimensions in inches. Tanks over 150 lb ship by LTL freight.
| Service | Closed hydronic systems only. Not for potable water: use GTXA for domestic hot water. |
| Sizing | Choose by acceptance volume, not tank volume. Acceptance must cover the system’s expansion from fill to maximum operating temperature. |
| Liquid | Water or water-glycol. |
| Pressure | Relief valve at or below the tank rating. |
Boiler and chilled water loops, radiant heating, heat pump and process cooling loops in commercial and institutional buildings.
| Shell | Steel |
| Diaphragm | Heavy-duty butyl, fixed |
| Exterior | Primer, black painted |
Product videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.
Sign up for our newsletter and be the first to know about coupons and special promotions.
© 2026, Watermainsupply