{"product_id":"zoeller-model-306-multi-stage-centrifugal-pump","title":"Zoeller Models 306-309 Two-Stage End Suction Centrifugal Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eZoeller · Centrifugal Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eModels 306-309 Two-Stage End Suction Centrifugal Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003e3\/4 to 2 HP · 115\/230V 1Ph\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e49-67 PSI Max Pressure · 41-55 GPM Max\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3\/4 to 2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115\/230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in Suction, 1-1\/4 in Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eTwo Stage, Cast Iron Case\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e56 Frame NEMA J Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eUp to 25 ft Suction Lift\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e67-72 lb Ship Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Zoeller Models 306-309 Two-Stage End Suction Centrifugal Pump line is listed here as one family of 4 builds (models 306, 307, 308, 309), 3\/4 to 2 HP. Pick the horsepower or flow class in the options; the model and its maximums show in the last option, and Zoeller’s printed performance for every model is in the tables below.\u003c\/p\u003e\n\u003cp\u003eOur Model 306 Multistage Centrifugal Pump is a non-self-priming solution designed for various applications. With capacities reaching up to 41 GPM and pressures up to 49 PSI, this multi-stage pump is specifically engineered for high head applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged cast iron pump casing, multi stage for high head\u003c\/li\u003e\n\u003cli\u003eNormal wearing parts are removed for service without disturbing the piping\u003c\/li\u003e\n\u003cli\u003eThermoplastic impeller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump and its motor, preassembled.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSuction and discharge piping, valves and controls:\u003c\/strong\u003e sized to the job and ordered separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Zoeller equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Zoeller Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003e1-Year Zoeller Limited Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eZoeller lists a \u003cstrong\u003e1-year limited warranty\u003c\/strong\u003e on this product. The start date and conditions are in Zoeller’s published warranty statement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e3\/4 to 2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115\/230V 1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPM\u003c\/td\u003e\n\u003ctd\u003e3450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller Type\u003c\/td\u003e\n\u003ctd\u003eClosed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller Material\u003c\/td\u003e\n\u003ctd\u003eEngineered Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e67-72 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eFrom Zoeller’s published product specifications. Shipping weight is the boxed weight Zoeller publishes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne block per model; open the model you are sizing.\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border:1px solid #C7CBD1;padding:8px 12px\" open\u003e\n\u003csummary style=\"font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1px;color:#B3122A;cursor:pointer\"\u003eModel 306 Multi-Stage Centrifugal Pump · 3\/4 HP\u003c\/summary\u003e\n\u003cp\u003eCapacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSuction lift\u003c\/th\u003e\n\u003cth\u003e10 PSI\u003c\/th\u003e\n\u003cth\u003e20 PSI\u003c\/th\u003e\n\u003cth\u003e30 PSI\u003c\/th\u003e\n\u003cth\u003e40 PSI\u003c\/th\u003e\n\n\n\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 ft\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\n\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\n\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\n\n\n\n\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eZoeller Technical Data, End Suction Centrifugal Pumps, FM3561, verbatim. A dash is a pressure the pump does not reach at that lift. Maximum pressure 49 PSI (113 ft). Do not exceed the maximum case pressure or liquid temperature.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border:1px solid #C7CBD1;padding:8px 12px\"\u003e\n\u003csummary style=\"font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1px;color:#B3122A;cursor:pointer\"\u003eModel 307 Multi-Stage Centrifugal Pump · 1 HP\u003c\/summary\u003e\n\u003cp\u003eCapacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSuction lift\u003c\/th\u003e\n\u003cth\u003e10 PSI\u003c\/th\u003e\n\u003cth\u003e20 PSI\u003c\/th\u003e\n\u003cth\u003e30 PSI\u003c\/th\u003e\n\u003cth\u003e40 PSI\u003c\/th\u003e\n\u003cth\u003e50 PSI\u003c\/th\u003e\n\n\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 ft\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\n\n\n\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eZoeller Technical Data, End Suction Centrifugal Pumps, FM3561, verbatim. A dash is a pressure the pump does not reach at that lift. Maximum pressure 60 PSI (138 ft). Do not exceed the maximum case pressure or liquid temperature.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border:1px solid #C7CBD1;padding:8px 12px\"\u003e\n\u003csummary style=\"font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1px;color:#B3122A;cursor:pointer\"\u003eModel 308 Multi-Stage Centrifugal Pump · 1-1\/2 HP\u003c\/summary\u003e\n\u003cp\u003eCapacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSuction lift\u003c\/th\u003e\n\u003cth\u003e10 PSI\u003c\/th\u003e\n\u003cth\u003e20 PSI\u003c\/th\u003e\n\u003cth\u003e30 PSI\u003c\/th\u003e\n\u003cth\u003e40 PSI\u003c\/th\u003e\n\u003cth\u003e50 PSI\u003c\/th\u003e\n\n\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 ft\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\n\n\n\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eZoeller Technical Data, End Suction Centrifugal Pumps, FM3561, verbatim. A dash is a pressure the pump does not reach at that lift. Maximum pressure 61 PSI (140 ft). Do not exceed the maximum case pressure or liquid temperature.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border:1px solid #C7CBD1;padding:8px 12px\"\u003e\n\u003csummary style=\"font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1px;color:#B3122A;cursor:pointer\"\u003eModel 309 Multi-Stage Centrifugal Pump · 2 HP\u003c\/summary\u003e\n\u003cp\u003eCapacity in GPM by suction lift (rows) and discharge pressure (columns), as Zoeller prints it.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSuction lift\u003c\/th\u003e\n\u003cth\u003e10 PSI\u003c\/th\u003e\n\u003cth\u003e20 PSI\u003c\/th\u003e\n\u003cth\u003e30 PSI\u003c\/th\u003e\n\u003cth\u003e40 PSI\u003c\/th\u003e\n\u003cth\u003e50 PSI\u003c\/th\u003e\n\u003cth\u003e60 PSI\u003c\/th\u003e\n\n\n\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 ft\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 ft\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\n\n\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eZoeller Technical Data, End Suction Centrifugal Pumps, FM3561, verbatim. A dash is a pressure the pump does not reach at that lift. Maximum pressure 67 PSI (154 ft). Do not exceed the maximum case pressure or liquid temperature.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/well-irrigation-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eWell \u0026amp; Irrigation Calculator\u003c\/a\u003e\u003ca href=\"\/pages\/pressure-tank-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eTank Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eClear water service; Zoeller lists no drinking water certification on this sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction\u003c\/td\u003e\n\u003ctd\u003eUp to 25 ft of suction lift; capacity falls as lift rises. Prime the pump before starting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003eDiffers by model; see the performance tables above.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115\/230V 1Ph, 60 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in suction, 1-1\/4 in discharge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e160°F maximum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email sales@watermainsupply.com or call 1-888.510.4036. © Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/FM0532-for-web.pdf?v=1794358051\" target=\"_blank\" rel=\"noopener\"\u003eCatalog, Zoeller Pump Company Pumps \u0026amp; Systems, FM0532\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"Zoeller","offers":[{"title":"3\/4 HP - 115\/230V 1Ph \/ 306-0006 - 49 PSI Max, 41 GPM Max","offer_id":50860551798959,"sku":"306-0006","price":1125.75,"currency_code":"USD","in_stock":true},{"title":"1 HP - 115\/230V 1Ph \/ 307-0006 - 60 PSI Max, 45 GPM Max","offer_id":50862544093359,"sku":"307-0006","price":1188.0,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 115\/230V 1Ph \/ 308-0006 - 61 PSI Max, 54 GPM Max","offer_id":50862544126127,"sku":"308-0006","price":1250.25,"currency_code":"USD","in_stock":true},{"title":"2 HP - 115\/230V 1Ph \/ 309-0006 - 67 PSI Max, 55 GPM Max","offer_id":50862544158895,"sku":"309-0006","price":1382.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Zoeller_306_CJ101-green-306-0006_773bf032-fcbd-40f9-97cd-816e9ff3af47.jpg?v=1794359188","url":"https:\/\/watermainsupply.com\/products\/zoeller-model-306-multi-stage-centrifugal-pump","provider":"Watermainsupply","version":"1.0","type":"link"}